Artificial intelligence in radiographic quantification and severity assessment of peri-implant marginal bone loss: A systematic review.

IF 3.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Hooman Khanzadeh, Sanaz Azizigermi, Aida Mokhlesi, Rasoul Gheisari, Gülce Çakmak, Pedro Molinero-Mourelle, Andrea Roccuzzo, Seyed Ali Mosaddad
{"title":"Artificial intelligence in radiographic quantification and severity assessment of peri-implant marginal bone loss: A systematic review.","authors":"Hooman Khanzadeh, Sanaz Azizigermi, Aida Mokhlesi, Rasoul Gheisari, Gülce Çakmak, Pedro Molinero-Mourelle, Andrea Roccuzzo, Seyed Ali Mosaddad","doi":"10.1111/jopr.70245","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To critically assess artificial intelligence (AI)-based radiographic models for quantitative measurement, localization/detection, segmentation/keypoints, diagnostic classification, and severity or morphology assessment of peri-implant marginal bone loss (MBL) and peri-implantitis-related bone defects.</p><p><strong>Methods: </strong>PubMed/MEDLINE, Scopus, Web of Science, Embase, the Cochrane Library, Google Scholar, and reference lists were searched from inception through August 11, 2026. Eligible original studies evaluated AI-based radiographic assessment of existing dental implants. Quality Assessment of Diagnostic Accuracy Studies-3 (QUADAS-3) was applied at the prespecified estimate level for diagnostic/image-analysis studies and PROBAST for the prediction-model study.</p><p><strong>Results: </strong>A total of 1485 records were identified, and 17 studies were included. Fourteen reported localization/detection outcomes, six segmentation/keypoint outcomes, 10 severity/morphology outcomes, 12 diagnostic/classification outcomes, and six direct AI-clinician comparisons; categories overlapped. Implant/peri-implant tissue detection reached precision of 0.977, recall of 0.992, F1 score of 0.984, and mean intersection over union (IoU) of 0.916. Implant segmentation achieved a Dice of 0.986 and IoU of 0.974, whereas downstream peri-implantitis classification precision was 0.777. Sensitivity across diagnostic/prediction tasks ranged from approximately 66% to 96%. No study reported the complete prespecified absolute MBL measurement-agreement outcome set. Six studies used explicitly independent multi-rater reference standards with consensus and/or reported reliability, and none underwent clearly traceable independent multicenter external validation.</p><p><strong>Conclusions: </strong>Reported performance is task-specific and is frequently derived from retrospectively selected, enriched, internally split, or augmented datasets. Current models may support research and carefully supervised radiographic image-analysis tasks, but none can be recommended for routine clinical use until independent multicenter external validation and prospective studies demonstrate clinically acceptable absolute measurement error and patient-relevant benefit.</p>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":" ","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2026-09-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jopr.70245","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To critically assess artificial intelligence (AI)-based radiographic models for quantitative measurement, localization/detection, segmentation/keypoints, diagnostic classification, and severity or morphology assessment of peri-implant marginal bone loss (MBL) and peri-implantitis-related bone defects.

Methods: PubMed/MEDLINE, Scopus, Web of Science, Embase, the Cochrane Library, Google Scholar, and reference lists were searched from inception through August 11, 2026. Eligible original studies evaluated AI-based radiographic assessment of existing dental implants. Quality Assessment of Diagnostic Accuracy Studies-3 (QUADAS-3) was applied at the prespecified estimate level for diagnostic/image-analysis studies and PROBAST for the prediction-model study.

Results: A total of 1485 records were identified, and 17 studies were included. Fourteen reported localization/detection outcomes, six segmentation/keypoint outcomes, 10 severity/morphology outcomes, 12 diagnostic/classification outcomes, and six direct AI-clinician comparisons; categories overlapped. Implant/peri-implant tissue detection reached precision of 0.977, recall of 0.992, F1 score of 0.984, and mean intersection over union (IoU) of 0.916. Implant segmentation achieved a Dice of 0.986 and IoU of 0.974, whereas downstream peri-implantitis classification precision was 0.777. Sensitivity across diagnostic/prediction tasks ranged from approximately 66% to 96%. No study reported the complete prespecified absolute MBL measurement-agreement outcome set. Six studies used explicitly independent multi-rater reference standards with consensus and/or reported reliability, and none underwent clearly traceable independent multicenter external validation.

Conclusions: Reported performance is task-specific and is frequently derived from retrospectively selected, enriched, internally split, or augmented datasets. Current models may support research and carefully supervised radiographic image-analysis tasks, but none can be recommended for routine clinical use until independent multicenter external validation and prospective studies demonstrate clinically acceptable absolute measurement error and patient-relevant benefit.

人工智能在种植体周围边缘骨丢失放射量化和严重程度评估中的应用:系统综述。
目的:批判性地评估基于人工智能(AI)的放射学模型在种植体周围边缘骨丢失(MBL)和种植体周围相关骨缺损的定量测量、定位/检测、分割/关键点、诊断分类、严重程度或形态学评估方面的应用。方法:检索PubMed/MEDLINE、Scopus、Web of Science、Embase、Cochrane Library、谷歌Scholar以及从建库到2026年8月11日的参考文献。符合条件的原始研究评估了基于人工智能的现有种植体放射评估。诊断准确性研究质量评估-3 (QUADAS-3)在预先指定的估计水平上应用于诊断/图像分析研究,PROBAST用于预测模型研究。结果:共纳入1485份记录,纳入17项研究。14个报告的定位/检测结果,6个分割/关键点结果,10个严重程度/形态学结果,12个诊断/分类结果,以及6个直接的人工智能临床医生比较;类别重叠。种植体/种植体周围组织检测精度为0.977,召回率为0.992,F1评分为0.984,平均IoU为0.916。种植体分割的准确率为0.986,IoU为0.974,下游种植体周围炎的分类精度为0.777。诊断/预测任务的灵敏度约为66%至96%。没有研究报告完整的预先规定的绝对MBL测量一致的结果集。6项研究使用明确独立的多指标参考标准,具有共识和/或报告的可靠性,没有一项研究进行了明确可追溯的独立多中心外部验证。结论:报告的表现是特定于任务的,并且经常来自回顾性选择,丰富,内部分裂或增强的数据集。目前的模型可以支持研究和仔细监督的放射图像分析任务,但在独立的多中心外部验证和前瞻性研究证明临床可接受的绝对测量误差和患者相关益处之前,没有一个模型可以推荐用于常规临床应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.90
自引率
15.00%
发文量
171
审稿时长
6-12 weeks
期刊介绍: The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书