Accuracy of an Interstitial Continuous Glucose Management System in Critically Ill Patients: A Prospective Observational Study.

IF 4.9 Q2 ENDOCRINOLOGY & METABOLISM
Marie Seret, Claire Dupuis, Vanessa Alves de Araújo, Claudio Annicchiarico, Gabriela Macedo, Caio Pinto Teixeira Araujo, Fabio Taccone, Miriam Cnop, Thomas Desaive, Vincent Uyttendaele, Jean-Charles Preiser
{"title":"Accuracy of an Interstitial Continuous Glucose Management System in Critically Ill Patients: A Prospective Observational Study.","authors":"Marie Seret, Claire Dupuis, Vanessa Alves de Araújo, Claudio Annicchiarico, Gabriela Macedo, Caio Pinto Teixeira Araujo, Fabio Taccone, Miriam Cnop, Thomas Desaive, Vincent Uyttendaele, Jean-Charles Preiser","doi":"10.1177/19322968261486451","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Glycemic management in the intensive care unit (ICU) remains challenging because glucose levels fluctuate rapidly and monitoring is intermittent. Interstitial continuous glucose monitoring (CGM) could improve surveillance, but its performance during rapid glucose excursions remains uncertain. We assessed the accuracy of the Dexcom G7 CGM in critically ill patients under stable conditions and during intravenous glucose tolerance tests (IVGTT).</p><p><strong>Methods: </strong>We conducted a prospective ancillary study of the Determination of Insulin Resistance in ICU (DIRICU) study. Twenty critically ill adults with stress hyperglycemia, no prior diabetes, and expected ICU stay ≥5 days were included. A Dexcom G7 sensor was compared with arterial blood glucose measurements. Accuracy was assessed over the first 10 ICU days using paired measurements, mean bias, mean absolute relative difference (MARD), linear regression (<i>R</i><sup>2</sup>), and Clarke error grid analysis, both outside and during IVGTT. A post hoc 20-minute temporal shift analysis was performed to account for delayed CGM peaks.</p><p><strong>Results: </strong>Outside IVGTT, 716 paired values showed moderate agreement with reference glucose (<i>R</i><sup>2</sup> = .58, mean bias +11 mg/dL, MARD 17%), with 98.9% of values in Clarke zones A/B. During IVGTT, accuracy deteriorated markedly (1018 paired values): <i>R</i><sup>2</sup> = .028, mean bias -34 mg/dL, MARD 24%, and only 80.3% of values in zones A/B, with 18.6% in zone D. After temporal shifting, performance improved (<i>R</i><sup>2</sup> = .34, MARD 19%, 94.7% in zones A/B). No sensor-related adverse events occurred.</p><p><strong>Conclusions: </strong>Dexcom G7 showed acceptable accuracy during stable ICU conditions, but performance deteriorated during rapid glucose excursions. Hybrid monitoring strategies combining CGM with intermittent blood glucose confirmation may therefore be preferable in critically ill patients.</p>","PeriodicalId":15475,"journal":{"name":"Journal of Diabetes Science and Technology","volume":" ","pages":"19322968261486451"},"PeriodicalIF":4.9000,"publicationDate":"2026-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13593934/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Diabetes Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/19322968261486451","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Glycemic management in the intensive care unit (ICU) remains challenging because glucose levels fluctuate rapidly and monitoring is intermittent. Interstitial continuous glucose monitoring (CGM) could improve surveillance, but its performance during rapid glucose excursions remains uncertain. We assessed the accuracy of the Dexcom G7 CGM in critically ill patients under stable conditions and during intravenous glucose tolerance tests (IVGTT).

Methods: We conducted a prospective ancillary study of the Determination of Insulin Resistance in ICU (DIRICU) study. Twenty critically ill adults with stress hyperglycemia, no prior diabetes, and expected ICU stay ≥5 days were included. A Dexcom G7 sensor was compared with arterial blood glucose measurements. Accuracy was assessed over the first 10 ICU days using paired measurements, mean bias, mean absolute relative difference (MARD), linear regression (R2), and Clarke error grid analysis, both outside and during IVGTT. A post hoc 20-minute temporal shift analysis was performed to account for delayed CGM peaks.

Results: Outside IVGTT, 716 paired values showed moderate agreement with reference glucose (R2 = .58, mean bias +11 mg/dL, MARD 17%), with 98.9% of values in Clarke zones A/B. During IVGTT, accuracy deteriorated markedly (1018 paired values): R2 = .028, mean bias -34 mg/dL, MARD 24%, and only 80.3% of values in zones A/B, with 18.6% in zone D. After temporal shifting, performance improved (R2 = .34, MARD 19%, 94.7% in zones A/B). No sensor-related adverse events occurred.

Conclusions: Dexcom G7 showed acceptable accuracy during stable ICU conditions, but performance deteriorated during rapid glucose excursions. Hybrid monitoring strategies combining CGM with intermittent blood glucose confirmation may therefore be preferable in critically ill patients.

危重患者间质持续血糖管理系统的准确性:一项前瞻性观察研究。
在重症监护病房(ICU)血糖管理仍然具有挑战性,因为血糖水平波动迅速,监测是间歇性的。间质性连续血糖监测(CGM)可以改善监测,但其在快速血糖漂移时的性能仍不确定。我们评估了病情稳定的危重患者和静脉糖耐量试验(IVGTT)期间Dexcom G7 CGM的准确性。方法:我们进行了一项关于ICU中胰岛素抵抗测定(DIRICU)的前瞻性辅助研究。纳入20例危重成人应激性高血糖,既往无糖尿病,预计ICU住院≥5天。Dexcom G7传感器与动脉血糖测量值进行比较。通过配对测量、平均偏倚、平均绝对相对差(MARD)、线性回归(R2)和Clarke误差网格分析,在IVGTT外和IVGTT期间评估前10个ICU天的准确性。进行了20分钟后的时间偏移分析,以解释延迟的CGM峰值。结果:在IVGTT外,716个配对值与参考血糖有中等程度的一致(R2 =。58,平均偏置+11 mg/dL, MARD为17%),其中Clarke区A/B值为98.9%。在IVGTT期间,准确度明显下降(1018对值):R2 =。028,平均偏差-34 mg/dL, MARD为24%,A/B区仅为80.3%,d区为18.6%。34, MARD 19%, A/B区94.7%)。未发生与传感器相关的不良事件。结论:Dexcom G7在稳定的ICU条件下具有可接受的准确性,但在快速葡萄糖漂移时性能下降。因此,将CGM与间歇性血糖确认相结合的混合监测策略可能更适合危重患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Diabetes Science and Technology
Journal of Diabetes Science and Technology Medicine-Internal Medicine
CiteScore
7.50
自引率
12.00%
发文量
148
期刊介绍: The Journal of Diabetes Science and Technology (JDST) is a bi-monthly, peer-reviewed scientific journal published by the Diabetes Technology Society. JDST covers scientific and clinical aspects of diabetes technology including glucose monitoring, insulin and metabolic peptide delivery, the artificial pancreas, digital health, precision medicine, social media, cybersecurity, software for modeling, physiologic monitoring, technology for managing obesity, and diagnostic tests of glycation. The journal also covers the development and use of mobile applications and wireless communication, as well as bioengineered tools such as MEMS, new biomaterials, and nanotechnology to develop new sensors. Articles in JDST cover both basic research and clinical applications of technologies being developed to help people with diabetes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书