Limitations of simple machine-learning surrogates for cross-tissue prediction of radial177Ludose point kernels.

IF 2 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Houcine Ennassiri
{"title":"Limitations of simple machine-learning surrogates for cross-tissue prediction of radial177Ludose point kernels.","authors":"Houcine Ennassiri","doi":"10.1088/2057-1976/aea427","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>To determine whether simple regularized linear regression models, relying solely on radial distance, mass density and elemental tissue composition as input features, can outperform the conventional water-kernel interpolation baseline for predicting radial dose point kernels (DPKs) ofacross a diverse set of homogeneous tissues and one additional low-density homogeneous medium.<i>Approach.</i>Radial DPKs forwere generated using OpenGATE 10 Monte Carlo simulations in 12 homogeneous media covering soft tissues, bone-like structures, and low-density lung-like tissues, together with one additional low-density homogeneous medium (g cm) evaluated separately as an out-of-distribution extrapolation test. Three scikit-learn models (RidgeCV, LassoCV, and ElasticNetCV) were trained with robust scaling and evaluated through leave-one-tissue-out (LOTO) and leave-one-family-out cross-validation, as well as on the independent low-density case. Performance was assessed using mean absolute percentage error on physical dose (), logarithmic root mean square error (), relative integral energy error, and relative errors onand, systematically compared against a water-kernel baseline obtained by linear resampling of a single simulated water DPK.<i>Main results.</i>ElasticNetCV was the best-performing linear surrogate overall, achieving a meanof 224% in LOTO validation (median 117%), followed by LassoCV and RidgeCV. However, none of the linear surrogates outperformed the water-kernel baseline on the main physical performance metrics. Mean gains relative to the baseline remained negative across tissue families, ranging from aboutpercentage points in bone-like tissues to aboutpercentage points in low-density lung-like tissues. Relative integral energy errors reached several thousand percent in lung-like media, and the separate low-density homogeneous medium also showed severe degradation (best surrogateversusfor the water-kernel baseline). Although some surrogate predictions showed lower log-domain errors than the baseline in selected cases, these improvements did not translate into better dosimetric accuracy in physical dose units.<i>Significance.</i>Simple linear machine-learning surrogates based on radial distance, mass density and macroscopic elemental composition did not improve, and often substantially worsened, the accuracy of radialDPK prediction compared with standard water-kernel interpolation. This negative benchmark delineates the limitations of basic tabular linear regression for capturing density- and composition-dependent kernel changes across a range of homogeneous media relevant to nuclear medicine dosimetry, and provides a reproducible reference framework for future development of more advanced surrogate models.</p>","PeriodicalId":8896,"journal":{"name":"Biomedical Physics & Engineering Express","volume":"12 5","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2026-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Physics & Engineering Express","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2057-1976/aea427","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objective.To determine whether simple regularized linear regression models, relying solely on radial distance, mass density and elemental tissue composition as input features, can outperform the conventional water-kernel interpolation baseline for predicting radial dose point kernels (DPKs) ofacross a diverse set of homogeneous tissues and one additional low-density homogeneous medium.Approach.Radial DPKs forwere generated using OpenGATE 10 Monte Carlo simulations in 12 homogeneous media covering soft tissues, bone-like structures, and low-density lung-like tissues, together with one additional low-density homogeneous medium (g cm) evaluated separately as an out-of-distribution extrapolation test. Three scikit-learn models (RidgeCV, LassoCV, and ElasticNetCV) were trained with robust scaling and evaluated through leave-one-tissue-out (LOTO) and leave-one-family-out cross-validation, as well as on the independent low-density case. Performance was assessed using mean absolute percentage error on physical dose (), logarithmic root mean square error (), relative integral energy error, and relative errors onand, systematically compared against a water-kernel baseline obtained by linear resampling of a single simulated water DPK.Main results.ElasticNetCV was the best-performing linear surrogate overall, achieving a meanof 224% in LOTO validation (median 117%), followed by LassoCV and RidgeCV. However, none of the linear surrogates outperformed the water-kernel baseline on the main physical performance metrics. Mean gains relative to the baseline remained negative across tissue families, ranging from aboutpercentage points in bone-like tissues to aboutpercentage points in low-density lung-like tissues. Relative integral energy errors reached several thousand percent in lung-like media, and the separate low-density homogeneous medium also showed severe degradation (best surrogateversusfor the water-kernel baseline). Although some surrogate predictions showed lower log-domain errors than the baseline in selected cases, these improvements did not translate into better dosimetric accuracy in physical dose units.Significance.Simple linear machine-learning surrogates based on radial distance, mass density and macroscopic elemental composition did not improve, and often substantially worsened, the accuracy of radialDPK prediction compared with standard water-kernel interpolation. This negative benchmark delineates the limitations of basic tabular linear regression for capturing density- and composition-dependent kernel changes across a range of homogeneous media relevant to nuclear medicine dosimetry, and provides a reproducible reference framework for future development of more advanced surrogate models.

简单的机器学习替代方法在放射177 ludose点核的跨组织预测中的局限性。
目标。为了确定单纯依赖径向距离、质量密度和元素组织组成作为输入特征的简单正则化线性回归模型,在预测径向剂量点核(DPKs)时,可以优于传统的水核插值基线。方法:径向剂量点核是使用OpenGATE 10蒙特卡罗模拟在12种均匀介质中生成的,包括软组织、骨样结构和低密度肺样组织。与一个额外的低密度均匀介质(g cm)一起单独评估,作为分布外外推检验。三个scikit-learn模型(RidgeCV、LassoCV和ElasticNetCV)进行了鲁棒缩放训练,并通过留一个组织(LOTO)和留一个家族(left -one family)交叉验证以及独立的低密度案例进行了评估。使用物理剂量的平均绝对百分比误差()、对数均方根误差()、相对积分能量误差和相对误差来评估性能,并与通过对单个模拟水DPK进行线性重采样获得的水核基线进行系统比较。主要的结果。总体而言,ElasticNetCV是表现最好的线性替代药物,在LOTO验证中平均达到224%(中位数为117%),其次是LassoCV和RidgeCV。然而,在主要的物理性能指标上,没有一个线性替代品优于水核基线。各组织科相对于基线的平均增益仍然为负,从骨样组织的约一个百分点到低密度肺样组织的约一个百分点不等。在肺样介质中,相对积分能量误差达到几千%,并且单独的低密度均匀介质也显示出严重的退化(与水核基线的最佳替代)。尽管在某些情况下,一些替代预测的对数域误差低于基线,但这些改进并不能转化为更好的物理剂量单位剂量学精度。意义:与标准水核插值相比,基于径向距离、质量密度和宏观元素组成的简单线性机器学习替代方法并没有提高径向dpk预测的准确性,而且往往会严重恶化。这一负基准描述了基本表格线性回归在捕获与核医学剂量学相关的一系列均质介质中密度和成分相关的核变化时的局限性,并为未来开发更先进的替代模型提供了可重复的参考框架。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomedical Physics & Engineering Express
Biomedical Physics & Engineering Express RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.80
自引率
0.00%
发文量
153
期刊介绍: BPEX is an inclusive, international, multidisciplinary journal devoted to publishing new research on any application of physics and/or engineering in medicine and/or biology. Characterized by a broad geographical coverage and a fast-track peer-review process, relevant topics include all aspects of biophysics, medical physics and biomedical engineering. Papers that are almost entirely clinical or biological in their focus are not suitable. The journal has an emphasis on publishing interdisciplinary work and bringing research fields together, encompassing experimental, theoretical and computational work.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书