[Determination of 15 fentanyl analogs and amphetamine-type stimulants in hair by liquid chromatography-tandem mass spectrometry and gas chromatography-mass spectrometry].

Qi Wei, Fu-Hai Su, Xin Zhu
{"title":"[Determination of 15 fentanyl analogs and amphetamine-type stimulants in hair by liquid chromatography-tandem mass spectrometry and gas chromatography-mass spectrometry].","authors":"Qi Wei, Fu-Hai Su, Xin Zhu","doi":"10.3724/SP.J.1123.2025.12005","DOIUrl":null,"url":null,"abstract":"<p><p>Drug abuse is a major global public health problem. Fentanyl analogs and amphetamine-type stimulants (ATS) are widely abused worldwide. Hair analysis can trace drug use history over months. This technique has unique advantages in forensic toxicology. However, its application is limited by a lack of matrix-certified reference materials (CRMs). At present, the existing CRMs are unable to simultaneously cover both fentanyl analogs and amphetamine-type stimulants. This study established a hair sample preparation method based on a water‑dimethyl sulfoxide‑hydrochloric acid soaking approach, targeting 15 analytes (nine fentanyl analogs and six ATS). The soaking time was systematically investigated. Drug incorporation into hair reached a maximum at 24 days. A slight decrease was observed at 25 days. This decrease may result from desorption and solvent-induced structural changes in keratin. Therefore, 24 days was selected as the optimal soaking time. Preparation experiments demonstrated that 14 of the 15 drugs were successfully embedded into the hair matrix. This study also applied a dual-platform quantitative strategy for certification. The two platforms were liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS). Cross-validation between the two platforms improved the reliability of certified values. Sample pretreatment conditions were optimized using Box-Behnken response surface methodology. Four factors were investigated: extraction temperature, extraction time, liquid-to-solid ratio, and hydrochloric acid concentration. The effects of the four factors on extraction efficiency followed a decreasing order: extraction temperature>extraction time>liquid-to-solid ratio>hydrochloric acid concentration. The optimal extraction conditions were as follows: extraction temperature 40 ℃, extraction time 50 min, liquid-solid ratio 100∶1 (mL/g), and hydrochloric acid concentration 0.01 mol/L. Method validation was performed according to international guidelines. For LC-MS/MS, the limits of detection (LODs) and quantification (LOQs) were 0.05 pg/mg and 0.25 pg/mg, respectively. For GC-MS, the LODs and LOQs were 0.02 ng/mg and 0.08 ng/mg, respectively. Good linearities were obtained for all 15 drugs. Correlation coefficients (<i>r</i>) were greater than 0.999 for both platforms. Good linearities were obtained for all 15 analytes on both platforms with correlation coefficients >0.999 over the respective concentration ranges Intra-day precisions (<i>n</i>=6) were evaluated as relative standard deviations (RSDs). Inter-day precision (<i>n</i>=30 over 5 days) was also calculated. For 14 drugs (except amphetamine), RSD values ranged from 0.2% to 9.4%. All RSDs were below 10%, indicating good repeatability and intermediate precision. Stability of hair extracts was assessed at 1, 24, 48, 72, and 96 h at room temperature. The extracts were stable for at least 96 h when stored at room temperature, with RSDs below 6.0% for LC-MS/MS and below 10% for GC-MS. Recovery tests were performed at three quality control levels (low, medium, high). For LC-MS/MS, average recoveries ranged from 84.46% to 116.4% (<i>n</i>=3). For GC-MS, average recoveries ranged from 85.50% to 116.4% (<i>n</i>=3). All RSDs were below 15%. Matrix effects (MEs) were evaluated by comparing matrix-matched standards with solvent standards. ME values between 80% and 120% (<i>n</i>=3) were observed for both platforms. These results indicate negligible ion suppression or enhancement. Homogeneity of the prepared hair reference material was assessed. The results show that the uniformity of the hair samples is good. The contents of the 14 drugs in the prepared hair samples were determined. For LC-MS/MS, the values ranged from 1.012 ng/mg to 7.830 ng/mg. For GC-MS, the values ranged from 1.087 ng/mg to 7.712 ng/mg. Amphetamine was not detected by either platform, likely due to its high polarity and weak binding to keratin. Most drugs showed good agreement between the two platforms. Relative deviations were below 10% for most analytes. However, methamphetamine showed a deviation of -12%. This may be due to matrix effects in LC-MS/MS. The GC-MS results for methamphetamine were more robust. The dual-platform approach allowed cross-validation and enhanced the reliability of the certified values. In conclusion, a dual-platform method based on LC-MS/MS and GC-MS was successfully applied to certify a new hair matrix reference material. The cross-validation strategy enhances the accuracy and traceability of the certified values. This work provides a valuable tool for quality control in forensic toxicology laboratories. The prepared reference material and validated method will facilitate inter-laboratory comparisons. They will also support the monitoring of drug abuse in forensic and clinical settings.</p>","PeriodicalId":101336,"journal":{"name":"Se pu = Chinese journal of chromatography","volume":"44 9","pages":"1048-1058"},"PeriodicalIF":0.0000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13586919/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Se pu = Chinese journal of chromatography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3724/SP.J.1123.2025.12005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Drug abuse is a major global public health problem. Fentanyl analogs and amphetamine-type stimulants (ATS) are widely abused worldwide. Hair analysis can trace drug use history over months. This technique has unique advantages in forensic toxicology. However, its application is limited by a lack of matrix-certified reference materials (CRMs). At present, the existing CRMs are unable to simultaneously cover both fentanyl analogs and amphetamine-type stimulants. This study established a hair sample preparation method based on a water‑dimethyl sulfoxide‑hydrochloric acid soaking approach, targeting 15 analytes (nine fentanyl analogs and six ATS). The soaking time was systematically investigated. Drug incorporation into hair reached a maximum at 24 days. A slight decrease was observed at 25 days. This decrease may result from desorption and solvent-induced structural changes in keratin. Therefore, 24 days was selected as the optimal soaking time. Preparation experiments demonstrated that 14 of the 15 drugs were successfully embedded into the hair matrix. This study also applied a dual-platform quantitative strategy for certification. The two platforms were liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS). Cross-validation between the two platforms improved the reliability of certified values. Sample pretreatment conditions were optimized using Box-Behnken response surface methodology. Four factors were investigated: extraction temperature, extraction time, liquid-to-solid ratio, and hydrochloric acid concentration. The effects of the four factors on extraction efficiency followed a decreasing order: extraction temperature>extraction time>liquid-to-solid ratio>hydrochloric acid concentration. The optimal extraction conditions were as follows: extraction temperature 40 ℃, extraction time 50 min, liquid-solid ratio 100∶1 (mL/g), and hydrochloric acid concentration 0.01 mol/L. Method validation was performed according to international guidelines. For LC-MS/MS, the limits of detection (LODs) and quantification (LOQs) were 0.05 pg/mg and 0.25 pg/mg, respectively. For GC-MS, the LODs and LOQs were 0.02 ng/mg and 0.08 ng/mg, respectively. Good linearities were obtained for all 15 drugs. Correlation coefficients (r) were greater than 0.999 for both platforms. Good linearities were obtained for all 15 analytes on both platforms with correlation coefficients >0.999 over the respective concentration ranges Intra-day precisions (n=6) were evaluated as relative standard deviations (RSDs). Inter-day precision (n=30 over 5 days) was also calculated. For 14 drugs (except amphetamine), RSD values ranged from 0.2% to 9.4%. All RSDs were below 10%, indicating good repeatability and intermediate precision. Stability of hair extracts was assessed at 1, 24, 48, 72, and 96 h at room temperature. The extracts were stable for at least 96 h when stored at room temperature, with RSDs below 6.0% for LC-MS/MS and below 10% for GC-MS. Recovery tests were performed at three quality control levels (low, medium, high). For LC-MS/MS, average recoveries ranged from 84.46% to 116.4% (n=3). For GC-MS, average recoveries ranged from 85.50% to 116.4% (n=3). All RSDs were below 15%. Matrix effects (MEs) were evaluated by comparing matrix-matched standards with solvent standards. ME values between 80% and 120% (n=3) were observed for both platforms. These results indicate negligible ion suppression or enhancement. Homogeneity of the prepared hair reference material was assessed. The results show that the uniformity of the hair samples is good. The contents of the 14 drugs in the prepared hair samples were determined. For LC-MS/MS, the values ranged from 1.012 ng/mg to 7.830 ng/mg. For GC-MS, the values ranged from 1.087 ng/mg to 7.712 ng/mg. Amphetamine was not detected by either platform, likely due to its high polarity and weak binding to keratin. Most drugs showed good agreement between the two platforms. Relative deviations were below 10% for most analytes. However, methamphetamine showed a deviation of -12%. This may be due to matrix effects in LC-MS/MS. The GC-MS results for methamphetamine were more robust. The dual-platform approach allowed cross-validation and enhanced the reliability of the certified values. In conclusion, a dual-platform method based on LC-MS/MS and GC-MS was successfully applied to certify a new hair matrix reference material. The cross-validation strategy enhances the accuracy and traceability of the certified values. This work provides a valuable tool for quality control in forensic toxicology laboratories. The prepared reference material and validated method will facilitate inter-laboratory comparisons. They will also support the monitoring of drug abuse in forensic and clinical settings.

[液相色谱-串联质谱法和气相色谱-质谱法测定头发中15种芬太尼类似物和安非他明类兴奋剂]。
药物滥用是一个重大的全球公共卫生问题。芬太尼类似物和安非他明类兴奋剂(ATS)在世界范围内被广泛滥用。头发分析可以追踪几个月的用药史。该技术在法医毒理学中具有独特的优势。然而,它的应用受到缺乏基质认证标准物质(crm)的限制。目前,现有的crm无法同时覆盖芬太尼类似物和安非他明类兴奋剂。本研究建立了一种基于水-二甲基亚砜-盐酸浸泡法的毛发样品制备方法,针对15种分析物(9种芬太尼类似物和6种ATS)。系统地研究了保温时间。药物在毛发中的掺入在第24天达到最大值。在第25天观察到略有下降。这种减少可能是由于解吸和溶剂引起的角蛋白结构变化。因此,选择24 d为最佳浸泡时间。制备实验表明,15种药物中有14种成功嵌入毛基质。本研究亦采用双平台量化认证策略。两个平台分别是液相色谱-串联质谱(LC-MS/MS)和气相色谱-质谱(GC-MS)。两个平台之间的交叉验证提高了认证值的可靠性。采用Box-Behnken响应面法优化样品预处理条件。考察了提取温度、提取时间、液固比和盐酸浓度四个因素。4个因素对提取效率的影响大小依次为:提取温度b>提取时间b>液固比>盐酸浓度。最佳提取条件为:提取温度40℃,提取时间50 min,液料比100∶1 (mL/g),盐酸浓度0.01 mol/L。方法验证按照国际标准进行。LC-MS/MS的检出限和定量限分别为0.05 pg/mg和0.25 pg/mg。气相色谱-质谱法的检出限和检出限分别为0.02 ng/mg和0.08 ng/mg。所有15种药物均具有良好的线性关系。两个平台的相关系数(r)均大于0.999。在两个平台上,15种分析物均具有良好的线性关系,相关系数为>0.999,在各自的浓度范围内,日内精密度(n=6)以相对标准偏差(rsd)进行评价。还计算了日间精度(n=30 / 5天)。除安非他明外,其余14种药物的RSD值在0.2% ~ 9.4%之间。rsd均在10%以下,重复性好,精密度中等。在室温下,分别在1、24、48、72和96小时评估头发提取物的稳定性。室温保存96 h以上,LC-MS/MS的rsd < 6.0%, GC-MS的rsd < 10%。在三个质量控制水平(低、中、高)下进行回收率试验。LC-MS/MS的平均加样回收率为84.46% ~ 116.4% (n=3)。GC-MS法平均加样回收率为85.50% ~ 116.4% (n=3)。所有rsd均小于15%。通过比较基质匹配标准和溶剂标准来评价基质效应。两个平台的ME值在80%到120%之间(n=3)。这些结果表明可以忽略不计的离子抑制或增强。对制备的毛发标准物质进行均匀性评价。结果表明,毛发样品的均匀性较好。测定制备的发样中14种药物的含量。LC-MS/MS的测定范围为1.012 ~ 7.830 ng/mg。气相色谱-质谱法测定范围为1.087 ~ 7.712 ng/mg。两种平台均未检测到安非他明,可能是由于其极性高且与角蛋白结合弱。大多数药物在两个平台之间表现出良好的一致性。大多数分析物的相对偏差低于10%。然而,甲基苯丙胺的偏差为-12%。这可能是由于LC-MS/MS中的基质效应。甲基苯丙胺的气相色谱-质谱分析结果更为稳定。双平台方法允许交叉验证,并增强了认证值的可靠性。综上所述,基于LC-MS/MS和GC-MS的双平台方法成功地验证了一种新的毛发基质标准物质。交叉验证策略提高了认证值的准确性和可追溯性。这项工作为法医毒理学实验室的质量控制提供了有价值的工具。所制备的标准物质和验证方法将便于实验室间的比较。它们还将支持在法医和临床环境中监测药物滥用情况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书