[Comparison of chiral separation performance of (2-hydroxyethyl-β)-cyclodextrin bonded superficially porous and fully porous particle chiral stationary phases in supercritical fluid chromatography and reversed-phase liquid chromatography].

Guang-Yong Yang, Hai-Jiang Wu, Huang-Tao Zhang, Hong-Li Wang, Qiu-Yan Liang
{"title":"[Comparison of chiral separation performance of (2-hydroxyethyl-<i>β</i>)-cyclodextrin bonded superficially porous and fully porous particle chiral stationary phases in supercritical fluid chromatography and reversed-phase liquid chromatography].","authors":"Guang-Yong Yang, Hai-Jiang Wu, Huang-Tao Zhang, Hong-Li Wang, Qiu-Yan Liang","doi":"10.3724/SP.J.1123.2025.12017","DOIUrl":null,"url":null,"abstract":"<p><p>Chromatography remains a cornerstone technique in analyzing chiral compounds. The development and selection of chiral stationary phases (CSPs) are central to achieving high-resolution enantiomeric separation. This study presents a novel regeneration and functionalization strategy for the preparation of high-performance superficially porous particle (SPP)-CSP, offering a promising alternative to conventional fully porous particle (FPP)-CSP. First, bonded phases on the surface of spent chromatographic column silica packing materials were removed using ultraviolet light (<i>λ</i>=254 nm) and hydrogen peroxide solution (3%, mass fraction), thereby obtaining sub-3 μm regenerated SPP. The regenerated SPP were then amino-functionalized. Subsequently, under mild reaction conditions, carbonyldiimidazole-activated (2-hydroxyethyl)-<i>β</i>-cyclodextrin (HE-<i>β</i>-CD) was bonded onto the surface of the amino-functionalized SPP to prepare the SPP-CSP. For comparative evaluation, a CSP based on 3 μm commercial FPPs was prepared. Additionally, a commercial (2-hydroxypropyl)-<i>β</i>-cyclodextrin (Hp-<i>β</i>-CD) chiral column with identical particle size and structure was selected as a reference. This commercial column was used to investigate the selectivity differences among different cyclodextrin derivatives. The enantioseparation and overall chromatographic performance of the CSPs were systematically evaluated under both supercritical fluid chromatography (SFC) and reversed-phase liquid chromatography (RPLC) modes. The evaluation was performed using ten chiral molecular probes: zopiclone, equol, 2-phenylpropionic acid, dobutamine, flutriafol, miconazole, folic acid, catechin, valacyclovir, and chlorphenamine. Results revealed that, under identical chromatographic conditions, the SPP-CSP consistently outperformed the FPP-CSP in terms of enantiomeric resolution, peak sharpness, theoretical plate number, and retention time efficiency. More importantly, the FPP-CSP exhibited a significant loss in resolution when chromatographic conditions were altered to yield equivalent analysis times. In contrast, the SPP-CSP showed only minor adverse effects on resolution when the flow rate was increased to shorten analysis time, highlighting its inherent suitability for ultrafast separations. Moreover, SFC and RPLC modes displayed complementary chiral recognition ranges. Within the overlapping separation scope of both modes, SFC mode achieved higher enantiomeric resolution and superior chromatographic performance. Notably, under RPLC mode, catechin showed high enantiomeric resolution on both CSPs, underscoring system-dependent selectivity differences. Multiple factors-including mobile phase composition (particularly the additive type), and the stereochemical structure of the analytes-were found to significantly influence enantioseparation outcomes. Under SFC mode, none of the analytes could be eluted when acetonitrile was used as the mobile phase modifier, whereas alcohols effectively enabled elution, with weaker hydrophobicity correlating to stronger elution strength. Among the alcohols tested, methanol offered distinct advantages over isopropanol by maintaining lower backpressure and superior chromatographic performance without compromising resolution. Under RPLC mode, although isopropanol as a mobile phase component provided higher enantiomeric resolution, it resulted in relatively poorer chromatographic performance and higher column pressure drop. Using acetonitrile offered limited flexibility in adjusting elution strength. In both chromatographic modes, the influence trends of mobile phase additives on enantioseparation performance and overall column performance were generally consistent. Mobile phases with acidic additives were more suitable for analyzing acidic analytes such as 2-phenylpropionic acid and folic acid. Mobile phases with ammonium formate were better suited for analyzing basic analytes like chlorphenamine and flutriafol, as well as analytes with p<i>K</i><sub>a</sub> values near 7, such as zopiclone. In contrast, NH<sub>3</sub> as an additive yielded unsatisfactory results. Compared with the commercial Hp-<i>β</i>-CD chiral column of the same particle size and structure, the SPP-CSP exhibited different selectivity, which varied with the chromatographic mode. Under RPLC mode, the SPP-CSP showed higher resolution for zopiclone, dobutamine, and folic acid. Under SFC mode, it demonstrated higher resolution for equol, folic acid, and valacyclovir. Despite these advances, the study has certain limitations. To enhance compatibility with mass spectrometric detection, normal-phase mode was not investigated. Additives commonly used in chiral compound analysis, such as triethylamine and ammonium trifluoroacetate, were also not employed. Polar organic solvent mode was not investigated either. Additionally, peak symmetry and theoretical plate numbers on the SPP-CSP were generally inferior to those observed on the commercial Hp-<i>β</i>-CD chiral column across both chromatographic modes.</p>","PeriodicalId":101336,"journal":{"name":"Se pu = Chinese journal of chromatography","volume":"44 9","pages":"1001-1009"},"PeriodicalIF":0.0000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13586918/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Se pu = Chinese journal of chromatography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3724/SP.J.1123.2025.12017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Chromatography remains a cornerstone technique in analyzing chiral compounds. The development and selection of chiral stationary phases (CSPs) are central to achieving high-resolution enantiomeric separation. This study presents a novel regeneration and functionalization strategy for the preparation of high-performance superficially porous particle (SPP)-CSP, offering a promising alternative to conventional fully porous particle (FPP)-CSP. First, bonded phases on the surface of spent chromatographic column silica packing materials were removed using ultraviolet light (λ=254 nm) and hydrogen peroxide solution (3%, mass fraction), thereby obtaining sub-3 μm regenerated SPP. The regenerated SPP were then amino-functionalized. Subsequently, under mild reaction conditions, carbonyldiimidazole-activated (2-hydroxyethyl)-β-cyclodextrin (HE-β-CD) was bonded onto the surface of the amino-functionalized SPP to prepare the SPP-CSP. For comparative evaluation, a CSP based on 3 μm commercial FPPs was prepared. Additionally, a commercial (2-hydroxypropyl)-β-cyclodextrin (Hp-β-CD) chiral column with identical particle size and structure was selected as a reference. This commercial column was used to investigate the selectivity differences among different cyclodextrin derivatives. The enantioseparation and overall chromatographic performance of the CSPs were systematically evaluated under both supercritical fluid chromatography (SFC) and reversed-phase liquid chromatography (RPLC) modes. The evaluation was performed using ten chiral molecular probes: zopiclone, equol, 2-phenylpropionic acid, dobutamine, flutriafol, miconazole, folic acid, catechin, valacyclovir, and chlorphenamine. Results revealed that, under identical chromatographic conditions, the SPP-CSP consistently outperformed the FPP-CSP in terms of enantiomeric resolution, peak sharpness, theoretical plate number, and retention time efficiency. More importantly, the FPP-CSP exhibited a significant loss in resolution when chromatographic conditions were altered to yield equivalent analysis times. In contrast, the SPP-CSP showed only minor adverse effects on resolution when the flow rate was increased to shorten analysis time, highlighting its inherent suitability for ultrafast separations. Moreover, SFC and RPLC modes displayed complementary chiral recognition ranges. Within the overlapping separation scope of both modes, SFC mode achieved higher enantiomeric resolution and superior chromatographic performance. Notably, under RPLC mode, catechin showed high enantiomeric resolution on both CSPs, underscoring system-dependent selectivity differences. Multiple factors-including mobile phase composition (particularly the additive type), and the stereochemical structure of the analytes-were found to significantly influence enantioseparation outcomes. Under SFC mode, none of the analytes could be eluted when acetonitrile was used as the mobile phase modifier, whereas alcohols effectively enabled elution, with weaker hydrophobicity correlating to stronger elution strength. Among the alcohols tested, methanol offered distinct advantages over isopropanol by maintaining lower backpressure and superior chromatographic performance without compromising resolution. Under RPLC mode, although isopropanol as a mobile phase component provided higher enantiomeric resolution, it resulted in relatively poorer chromatographic performance and higher column pressure drop. Using acetonitrile offered limited flexibility in adjusting elution strength. In both chromatographic modes, the influence trends of mobile phase additives on enantioseparation performance and overall column performance were generally consistent. Mobile phases with acidic additives were more suitable for analyzing acidic analytes such as 2-phenylpropionic acid and folic acid. Mobile phases with ammonium formate were better suited for analyzing basic analytes like chlorphenamine and flutriafol, as well as analytes with pKa values near 7, such as zopiclone. In contrast, NH3 as an additive yielded unsatisfactory results. Compared with the commercial Hp-β-CD chiral column of the same particle size and structure, the SPP-CSP exhibited different selectivity, which varied with the chromatographic mode. Under RPLC mode, the SPP-CSP showed higher resolution for zopiclone, dobutamine, and folic acid. Under SFC mode, it demonstrated higher resolution for equol, folic acid, and valacyclovir. Despite these advances, the study has certain limitations. To enhance compatibility with mass spectrometric detection, normal-phase mode was not investigated. Additives commonly used in chiral compound analysis, such as triethylamine and ammonium trifluoroacetate, were also not employed. Polar organic solvent mode was not investigated either. Additionally, peak symmetry and theoretical plate numbers on the SPP-CSP were generally inferior to those observed on the commercial Hp-β-CD chiral column across both chromatographic modes.

[(2-羟乙基-β)-环糊精键合表面多孔和全多孔颗粒手性固定相在超临界流体色谱和反相液相色谱中的手性分离性能比较]。
色谱法仍然是分析手性化合物的基础技术。开发和选择手性固定相(CSPs)是实现高分辨率对映体分离的核心。本研究提出了一种新的再生和功能化策略,用于制备高性能的表面多孔颗粒(SPP)-CSP,为传统的全多孔颗粒(FPP)-CSP提供了一种有前途的替代品。首先,利用紫外光(λ=254 nm)和过氧化氢溶液(3%,质量分数)去除废色谱柱二氧化硅填料表面的键合相,得到亚3 μm的再生SPP,并对再生SPP进行氨基功能化处理。随后,在温和反应条件下,羰基二咪唑活化(2-羟乙基)-β-环糊精(HE-β-CD)键合到氨基功能化的SPP表面,制备SPP- csp。为了进行比较评价,制备了基于3 μm商用FPPs的CSP。另外,选择具有相同粒径和结构的(2-羟丙基)-β-环糊精(Hp-β-CD)手性色谱柱作为对照。利用该色谱柱考察了不同环糊精衍生物的选择性差异。在超临界流体色谱(SFC)和反相液相色谱(RPLC)两种模式下,对csp的对映体分离性能和整体色谱性能进行了系统评价。采用10种手性分子探针进行评价:唑匹克隆、马酚、2-苯丙酸、多巴酚丁胺、氟triafol、咪康唑、叶酸、儿茶素、伐昔洛韦和氯苯那明。结果表明,在相同的色谱条件下,SPP-CSP在对映体分辨率、峰清晰度、理论板数和保留时间效率方面均优于FPP-CSP。更重要的是,当色谱条件改变以产生等效的分析时间时,FPP-CSP表现出明显的分辨率损失。相比之下,当流速增加以缩短分析时间时,SPP-CSP对分辨率只有轻微的不利影响,突出了其固有的超快分离适用性。此外,SFC和RPLC模式的手性识别范围是互补的。在两种模式的重叠分离范围内,SFC模式获得了更高的对映体分辨率和更好的色谱性能。值得注意的是,在RPLC模式下,儿茶素在两种csp上表现出较高的对映体分辨率,强调了系统依赖性的选择性差异。多种因素——包括流动相组成(特别是添加剂类型)和分析物的立体化学结构——被发现显著影响对映体分离结果。在SFC模式下,以乙腈作为流动相改性剂时,所有的分析物都不能被洗脱,而醇类有效地洗脱,疏水性越弱,洗脱强度越强。在测试的醇类中,甲醇具有明显的优势,可以保持较低的背压和优越的色谱性能,而不影响分辨率。在RPLC模式下,虽然异丙醇作为流动相组分具有较高的对映体分辨率,但其色谱性能相对较差,柱压降较高。使用乙腈在调整洗脱强度方面提供了有限的灵活性。在两种色谱模式下,流动相添加剂对对映体分离性能和整体柱性能的影响趋势基本一致。添加酸性添加剂的流动相更适合分析2-苯基丙酸和叶酸等酸性分析物。甲酸铵流动相更适合分析氯非那明和氟三酚等碱性分析物,以及pKa值接近7的分析物,如佐匹克隆。相比之下,NH3作为添加剂产生了不满意的结果。与相同粒径和结构的Hp-β-CD手性柱相比,SPP-CSP具有不同的选择性,其选择性随色谱方式的不同而不同。在RPLC模式下,SPP-CSP对唑匹克隆、多巴酚丁胺和叶酸具有较高的分辨率。在SFC模式下,对马雌酚、叶酸和伐昔洛韦具有较高的分辨率。尽管取得了这些进展,但这项研究仍有一定的局限性。为了提高与质谱检测的兼容性,没有研究正相模式。手性化合物分析中常用的添加剂,如三乙胺和三氟乙酸铵,也没有使用。极性有机溶剂模式也未进行研究。此外,在两种色谱模式下,SPP-CSP上的峰对称性和理论板数通常不如在商用Hp-β-CD手性柱上观察到的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书