{"title":"Design of a multitissue osteoarticular 3D-Printed knee model for initial training in meniscal repair.","authors":"Manon Pignero, Javier Arduengo Garcia, Jean Yves Hascoet, Cyrille Decante, Julien Berhouet, Herve Thomazeau, Vincent Biscaccianti, Vincent Crenn","doi":"10.1051/sicotj/2026046","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Meniscal preservation is essential, given the degenerative risk associated with meniscectomy. Consequently, meniscal repair is a key technical skill to be acquired early during surgical training. However, resident education is limited by restricted access to human models. While artificial simulators represent an alternative, their use is often constrained by high cost and limited biomechanical or arthroscopic realism. The aim of this project was to design and evaluate a 3D-printed arthroscopic simulator dedicated to meniscal repair, developed through a collaboration between orthopedic surgeons and engineers, in order to provide an accessible and realistic educational tool.</p><p><strong>Methods: </strong>Modeling and design were jointly performed by orthopedic surgeons and engineers based on segmentation of medical imaging data. A complete lower limb was created, incorporating a removable capsulomeniscal complex. Osseous and cartilaginous structures were produced by direct 3D printing, while ligaments and the capsulomeniscal complex were molded in silicone using 3D-printed templates. This removable complex differentiates peripheral capsular insertions from meniscal roots, reproducing the anatomical constraints. The model was assessed through a subjective evaluation of arthroscopic realism during meniscal suturing procedures by two independent knee surgery experts.</p><p><strong>Results: </strong>The prototype reproduces a complete lower limb articulated around a fixed femoral pivot, with near-physiological hip and knee motion. It allows dry arthroscopy for various meniscal tear patterns and requires Cabot and valgus maneuvers for optimal femorotibial exposure. Ramp lesions can be repaired via a postero-medial approach using a hook instrument, whereas osseous procedures such as meniscal root reinsertion remain unfeasible. Both evaluators rated as \"very realistic\" the anatomy, haptic feedback, and ramp lesion suturing. Overall, arthroscopic realism was rated as \"very realistic\" by both.</p><p><strong>Conclusion: </strong>This study presents a realistic 3D-printed simulator for meniscal repair, addressing a clear educational need. Further development and large-scale validation studies involving trainees are required to confirm its pedagogical relevance. Study type / Level of evidence: Experimental design study / Level IV.</p>","PeriodicalId":46378,"journal":{"name":"SICOT-J","volume":"12 ","pages":"54"},"PeriodicalIF":2.4000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13584642/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SICOT-J","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/sicotj/2026046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/18 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Meniscal preservation is essential, given the degenerative risk associated with meniscectomy. Consequently, meniscal repair is a key technical skill to be acquired early during surgical training. However, resident education is limited by restricted access to human models. While artificial simulators represent an alternative, their use is often constrained by high cost and limited biomechanical or arthroscopic realism. The aim of this project was to design and evaluate a 3D-printed arthroscopic simulator dedicated to meniscal repair, developed through a collaboration between orthopedic surgeons and engineers, in order to provide an accessible and realistic educational tool.

Methods: Modeling and design were jointly performed by orthopedic surgeons and engineers based on segmentation of medical imaging data. A complete lower limb was created, incorporating a removable capsulomeniscal complex. Osseous and cartilaginous structures were produced by direct 3D printing, while ligaments and the capsulomeniscal complex were molded in silicone using 3D-printed templates. This removable complex differentiates peripheral capsular insertions from meniscal roots, reproducing the anatomical constraints. The model was assessed through a subjective evaluation of arthroscopic realism during meniscal suturing procedures by two independent knee surgery experts.

Results: The prototype reproduces a complete lower limb articulated around a fixed femoral pivot, with near-physiological hip and knee motion. It allows dry arthroscopy for various meniscal tear patterns and requires Cabot and valgus maneuvers for optimal femorotibial exposure. Ramp lesions can be repaired via a postero-medial approach using a hook instrument, whereas osseous procedures such as meniscal root reinsertion remain unfeasible. Both evaluators rated as "very realistic" the anatomy, haptic feedback, and ramp lesion suturing. Overall, arthroscopic realism was rated as "very realistic" by both.

Conclusion: This study presents a realistic 3D-printed simulator for meniscal repair, addressing a clear educational need. Further development and large-scale validation studies involving trainees are required to confirm its pedagogical relevance. Study type / Level of evidence: Experimental design study / Level IV.

用于半月板修复初始训练的多组织骨关节3d打印膝关节模型的设计。
目的:半月板保存是必要的,考虑到与半月板切除术相关的退行性风险。因此,半月板修复是外科训练早期需要掌握的一项关键技术技能。然而,居民教育受到人体模型的限制。虽然人工模拟器是另一种选择,但它们的使用往往受到高成本和有限的生物力学或关节镜真实性的限制。该项目的目的是设计和评估一个专门用于半月板修复的3d打印关节镜模拟器,通过骨科医生和工程师之间的合作开发,以提供一个可访问和现实的教育工具。方法:在医学影像数据分割的基础上,由骨科医生和工程师共同进行建模和设计。一个完整的下肢被创造出来,包括一个可移动的结膜复合体。骨性和软骨结构通过直接3D打印产生,而韧带和结膜复合体则使用3D打印模板在硅胶中成型。这个可移动的复合体区分了外周包膜插入和半月板根,再现了解剖学上的限制。该模型由两名独立的膝关节外科专家在半月板缝合过程中通过关节镜真实性的主观评估进行评估。结果:该原型再现了一个完整的下肢关节周围的固定股骨枢轴,具有接近生理的髋关节和膝关节运动。它允许干性关节镜检查各种半月板撕裂模式,需要Cabot和外翻操作以获得最佳的股胫暴露。斜坡病变可通过后内侧入路使用钩状器械进行修复,而诸如半月板根植入等骨手术仍然不可行的。两位评估者都认为解剖、触觉反馈和斜坡损伤缝合“非常真实”。总的来说,关节镜的真实感被两者评为“非常逼真”。结论:本研究提出了一个现实的3d打印半月板修复模拟器,解决了明确的教育需求。需要进一步发展和涉及受训者的大规模验证研究,以确认其教学意义。研究类型/证据水平:实验设计研究/ IV级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
SICOT-J
SICOT-J ORTHOPEDICS-
CiteScore
3.20
自引率
12.50%
发文量
44
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书