Hepatic reticuloendothelial distribution on sulfur colloid single-photon emission computed tomography/computed tomography is discordant with biochemical liver function in patients undergoing preradioembolization evaluation.

IF 1.4 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Syed Hasan Raza, Zachary Nuffer, Neal Savjani, Ayman Farag, Arash Kardan
{"title":"Hepatic reticuloendothelial distribution on sulfur colloid single-photon emission computed tomography/computed tomography is discordant with biochemical liver function in patients undergoing preradioembolization evaluation.","authors":"Syed Hasan Raza, Zachary Nuffer, Neal Savjani, Ayman Farag, Arash Kardan","doi":"10.1097/MNM.0000000000002241","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To determine whether qualitative technetium-99m sulfur colloid (99mTc-SC) single-photon emission computed tomography/computed tomography (SPECT/CT) grading is discordant with conventional liver function assessment in patients undergoing preradioembolization evaluation.</p><p><strong>Methods: </strong>This single-center retrospective study included 96 consecutive patients who underwent dual-tracer 99mTc-macroaggregated albumin and 99mTc-SC SPECT/CT for yttrium-90 transarterial radioembolization planning. Sulfur colloid uptake was graded visually on a three-tier ordinal scale: grade I, normal; grade II, intermediate; and grade III, colloid shift. Contemporaneous laboratory values, Child-Pugh class, and model for end-stage liver disease score were recorded. Concordance was assessed using weighted kappa. Associations were evaluated with Spearman correlation, receiver operating characteristic analysis, and ordinal logistic regression.</p><p><strong>Results: </strong>Abnormal sulfur colloid findings, defined as grade II/III uptake, were present in 19 of 96 patients (19.8%), including eight patients (8.3%) with grade III colloid shift. Among 85 Child-Pugh A patients, 15 (17.6%) had abnormal sulfur colloid uptake; among 70 lab-normal patients, 11 (15.7%) had abnormal sulfur colloid uptake. Agreement between sulfur colloid grade and Child-Pugh class was poor (weighted kappa: 0.142). Higher sulfur colloid grade correlated modestly with albumin, total bilirubin, international normalized ratio, aspartate aminotransferase, and creatinine, but no variable remained independently associated after adjustment. Albumin best discriminated grade III shift [area under the curve (AUC): 0.732], whereas Child-Pugh class performed near chance (AUC: 0.511).</p><p><strong>Conclusion: </strong>Sulfur colloid SPECT/CT demonstrates reticuloendothelial distribution abnormalities in approximately one-fifth of preradioembolization patients, including some with preserved biochemical function. These discordant findings support further outcome-anchored evaluation of sulfur colloid SPECT/CT as a complementary tool before Y-90 radioembolization.</p>","PeriodicalId":19708,"journal":{"name":"Nuclear Medicine Communications","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2026-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Medicine Communications","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MNM.0000000000002241","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To determine whether qualitative technetium-99m sulfur colloid (99mTc-SC) single-photon emission computed tomography/computed tomography (SPECT/CT) grading is discordant with conventional liver function assessment in patients undergoing preradioembolization evaluation.

Methods: This single-center retrospective study included 96 consecutive patients who underwent dual-tracer 99mTc-macroaggregated albumin and 99mTc-SC SPECT/CT for yttrium-90 transarterial radioembolization planning. Sulfur colloid uptake was graded visually on a three-tier ordinal scale: grade I, normal; grade II, intermediate; and grade III, colloid shift. Contemporaneous laboratory values, Child-Pugh class, and model for end-stage liver disease score were recorded. Concordance was assessed using weighted kappa. Associations were evaluated with Spearman correlation, receiver operating characteristic analysis, and ordinal logistic regression.

Results: Abnormal sulfur colloid findings, defined as grade II/III uptake, were present in 19 of 96 patients (19.8%), including eight patients (8.3%) with grade III colloid shift. Among 85 Child-Pugh A patients, 15 (17.6%) had abnormal sulfur colloid uptake; among 70 lab-normal patients, 11 (15.7%) had abnormal sulfur colloid uptake. Agreement between sulfur colloid grade and Child-Pugh class was poor (weighted kappa: 0.142). Higher sulfur colloid grade correlated modestly with albumin, total bilirubin, international normalized ratio, aspartate aminotransferase, and creatinine, but no variable remained independently associated after adjustment. Albumin best discriminated grade III shift [area under the curve (AUC): 0.732], whereas Child-Pugh class performed near chance (AUC: 0.511).

Conclusion: Sulfur colloid SPECT/CT demonstrates reticuloendothelial distribution abnormalities in approximately one-fifth of preradioembolization patients, including some with preserved biochemical function. These discordant findings support further outcome-anchored evaluation of sulfur colloid SPECT/CT as a complementary tool before Y-90 radioembolization.

硫胶体单光子发射计算机断层扫描/计算机断层扫描显示肝脏网状内皮分布与放射前栓塞评估患者的生化肝功能不一致。
目的:探讨放射前栓塞评估患者定性锝-99m硫胶体(99mTc-SC)单光子发射计算机断层扫描/计算机断层扫描(SPECT/CT)分级与常规肝功能评估是否不一致。方法:这项单中心回顾性研究包括96例连续患者,他们接受了双示踪剂99mtc -巨聚集白蛋白和99mTc-SC SPECT/CT进行钇-90经动脉放射栓塞计划。硫胶体吸收量按三级顺序分级:I级,正常;二级,中级;三级:胶体移位。记录同期实验室值、Child-Pugh分级和终末期肝病评分模型。使用加权kappa评估一致性。采用Spearman相关、受试者工作特征分析和有序逻辑回归评估相关性。结果:96例患者中有19例(19.8%)出现硫胶体异常,定义为II/III级摄取,其中8例(8.3%)出现III级胶体移位。85例Child-Pugh A患者中,硫胶体摄取异常15例(17.6%);70例实验室正常患者中,有11例(15.7%)硫胶体摄取异常。硫胶体等级与Child-Pugh等级的一致性较差(加权kappa: 0.142)。较高的硫胶体等级与白蛋白、总胆红素、国际标准化比值、天冬氨酸转氨酶和肌酐有一定的相关性,但调整后没有变量保持独立相关。白蛋白最能区分III级移位[曲线下面积(AUC): 0.732],而Child-Pugh类表现接近机会(AUC: 0.511)。结论:硫胶体SPECT/CT显示约五分之一的放射栓塞前患者网状内皮分布异常,包括一些保留生化功能的患者。这些不一致的发现支持进一步的结果锚定评估硫胶体SPECT/CT作为Y-90放射栓塞前的补充工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.20
自引率
6.70%
发文量
212
审稿时长
3-8 weeks
期刊介绍: Nuclear Medicine Communications, the official journal of the British Nuclear Medicine Society, is a rapid communications journal covering nuclear medicine and molecular imaging with radionuclides, and the basic supporting sciences. As well as clinical research and commentary, manuscripts describing research on preclinical and basic sciences (radiochemistry, radiopharmacy, radiobiology, radiopharmacology, medical physics, computing and engineering, and technical and nursing professions involved in delivering nuclear medicine services) are welcomed, as the journal is intended to be of interest internationally to all members of the many medical and non-medical disciplines involved in nuclear medicine. In addition to papers reporting original studies, frankly written editorials and topical reviews are a regular feature of the journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书