{"title":"Impact of 4D-CT MIP reconstruction method on iGTV definition: A clinical case report","authors":"Suhong Yu, Itai Pashtan","doi":"10.1002/acm2.70799","DOIUrl":null,"url":null,"abstract":"<p>To present a clinical case demonstrating the impact of 4D-CT maximum intensity projection (MIP) reconstruction methodology on internal gross tumor volume (iGTV) definition and to highlight implications for motion management quality assurance. During routine thoracic radiation therapy treatment planning, a discrepancy in tumor extent was identified during physician contouring. The inferior extent of the tumor appeared artificially truncated on the MIP dataset used for target delineation. Further review revealed that the default MIP had been generated from phase-sorted 4D-CT images. A comparison was performed between the phase-sorted MIP and a MIP reconstructed from the original cine images to evaluate differences in motion representation. The phase-sorted MIP under-represented the full tumor motion envelope, most notably in the inferior direction. In contrast, the cine-based MIP demonstrated a more complete representation of tumor extent throughout respiration. This discrepancy was not readily apparent during the routine clinical workflow, and verification of the MIP reconstruction method was not part of the standard QA review process at the time. Differences in MIP reconstruction methodology can impact iGTV definition. Although these differences may be subtle in most cases, clinically meaningful discrepancies may occur, particularly in patients with irregular breathing patterns. This case highlights the importance of awareness and verification of 4D-CT MIP reconstruction methods and supports comprehensive QA across CT simulation, treatment planning, and motion management workflows.</p>","PeriodicalId":14989,"journal":{"name":"Journal of Applied Clinical Medical Physics","volume":"27 10","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2026-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/acm2.70799","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Clinical Medical Physics","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/acm2.70799","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
To present a clinical case demonstrating the impact of 4D-CT maximum intensity projection (MIP) reconstruction methodology on internal gross tumor volume (iGTV) definition and to highlight implications for motion management quality assurance. During routine thoracic radiation therapy treatment planning, a discrepancy in tumor extent was identified during physician contouring. The inferior extent of the tumor appeared artificially truncated on the MIP dataset used for target delineation. Further review revealed that the default MIP had been generated from phase-sorted 4D-CT images. A comparison was performed between the phase-sorted MIP and a MIP reconstructed from the original cine images to evaluate differences in motion representation. The phase-sorted MIP under-represented the full tumor motion envelope, most notably in the inferior direction. In contrast, the cine-based MIP demonstrated a more complete representation of tumor extent throughout respiration. This discrepancy was not readily apparent during the routine clinical workflow, and verification of the MIP reconstruction method was not part of the standard QA review process at the time. Differences in MIP reconstruction methodology can impact iGTV definition. Although these differences may be subtle in most cases, clinically meaningful discrepancies may occur, particularly in patients with irregular breathing patterns. This case highlights the importance of awareness and verification of 4D-CT MIP reconstruction methods and supports comprehensive QA across CT simulation, treatment planning, and motion management workflows.
期刊介绍:
Journal of Applied Clinical Medical Physics is an international Open Access publication dedicated to clinical medical physics. JACMP welcomes original contributions dealing with all aspects of medical physics from scientists working in the clinical medical physics around the world. JACMP accepts only online submission.
JACMP will publish:
-Original Contributions: Peer-reviewed, investigations that represent new and significant contributions to the field. Recommended word count: up to 7500.
-Review Articles: Reviews of major areas or sub-areas in the field of clinical medical physics. These articles may be of any length and are peer reviewed.
-Technical Notes: These should be no longer than 3000 words, including key references.
-Letters to the Editor: Comments on papers published in JACMP or on any other matters of interest to clinical medical physics. These should not be more than 1250 (including the literature) and their publication is only based on the decision of the editor, who occasionally asks experts on the merit of the contents.
-Book Reviews: The editorial office solicits Book Reviews.
-Announcements of Forthcoming Meetings: The Editor may provide notice of forthcoming meetings, course offerings, and other events relevant to clinical medical physics.
-Parallel Opposed Editorial: We welcome topics relevant to clinical practice and medical physics profession. The contents can be controversial debate or opposed aspects of an issue. One author argues for the position and the other against. Each side of the debate contains an opening statement up to 800 words, followed by a rebuttal up to 500 words. Readers interested in participating in this series should contact the moderator with a proposed title and a short description of the topic