Impact of 4D-CT MIP reconstruction method on iGTV definition: A clinical case report

IF 2.5 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Suhong Yu, Itai Pashtan
{"title":"Impact of 4D-CT MIP reconstruction method on iGTV definition: A clinical case report","authors":"Suhong Yu,&nbsp;Itai Pashtan","doi":"10.1002/acm2.70799","DOIUrl":null,"url":null,"abstract":"<p>To present a clinical case demonstrating the impact of 4D-CT maximum intensity projection (MIP) reconstruction methodology on internal gross tumor volume (iGTV) definition and to highlight implications for motion management quality assurance. During routine thoracic radiation therapy treatment planning, a discrepancy in tumor extent was identified during physician contouring. The inferior extent of the tumor appeared artificially truncated on the MIP dataset used for target delineation. Further review revealed that the default MIP had been generated from phase-sorted 4D-CT images. A comparison was performed between the phase-sorted MIP and a MIP reconstructed from the original cine images to evaluate differences in motion representation. The phase-sorted MIP under-represented the full tumor motion envelope, most notably in the inferior direction. In contrast, the cine-based MIP demonstrated a more complete representation of tumor extent throughout respiration. This discrepancy was not readily apparent during the routine clinical workflow, and verification of the MIP reconstruction method was not part of the standard QA review process at the time. Differences in MIP reconstruction methodology can impact iGTV definition. Although these differences may be subtle in most cases, clinically meaningful discrepancies may occur, particularly in patients with irregular breathing patterns. This case highlights the importance of awareness and verification of 4D-CT MIP reconstruction methods and supports comprehensive QA across CT simulation, treatment planning, and motion management workflows.</p>","PeriodicalId":14989,"journal":{"name":"Journal of Applied Clinical Medical Physics","volume":"27 10","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2026-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/acm2.70799","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Clinical Medical Physics","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/acm2.70799","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

To present a clinical case demonstrating the impact of 4D-CT maximum intensity projection (MIP) reconstruction methodology on internal gross tumor volume (iGTV) definition and to highlight implications for motion management quality assurance. During routine thoracic radiation therapy treatment planning, a discrepancy in tumor extent was identified during physician contouring. The inferior extent of the tumor appeared artificially truncated on the MIP dataset used for target delineation. Further review revealed that the default MIP had been generated from phase-sorted 4D-CT images. A comparison was performed between the phase-sorted MIP and a MIP reconstructed from the original cine images to evaluate differences in motion representation. The phase-sorted MIP under-represented the full tumor motion envelope, most notably in the inferior direction. In contrast, the cine-based MIP demonstrated a more complete representation of tumor extent throughout respiration. This discrepancy was not readily apparent during the routine clinical workflow, and verification of the MIP reconstruction method was not part of the standard QA review process at the time. Differences in MIP reconstruction methodology can impact iGTV definition. Although these differences may be subtle in most cases, clinically meaningful discrepancies may occur, particularly in patients with irregular breathing patterns. This case highlights the importance of awareness and verification of 4D-CT MIP reconstruction methods and supports comprehensive QA across CT simulation, treatment planning, and motion management workflows.

Abstract Image

4D-CT MIP重建方法对iGTV清晰度的影响1例临床报告。
提出一个临床案例,展示4D-CT最大强度投影(MIP)重建方法对内部总肿瘤体积(iGTV)定义的影响,并强调运动管理质量保证的意义。在常规的胸部放射治疗计划中,在医师轮廓中发现肿瘤范围的差异。肿瘤的下半部在MIP数据集上被人为截断,用于目标描绘。进一步检查发现,默认的MIP是由相位排序的4D-CT图像生成的。将相位排序的MIP与从原始电影图像重建的MIP进行比较,以评估运动表示的差异。相位分类的MIP不能代表完整的肿瘤运动包络,尤其是在下方向。相比之下,基于电影的MIP在整个呼吸过程中表现出更完整的肿瘤范围。这种差异在常规临床工作流程中并不明显,并且MIP重建方法的验证当时不是标准QA审查过程的一部分。MIP重建方法的差异会影响iGTV的定义。虽然这些差异在大多数情况下可能是细微的,但临床上有意义的差异可能会出现,特别是在呼吸模式不规则的患者中。该案例强调了对4D-CT MIP重建方法的认识和验证的重要性,并为CT模拟、治疗计划和运动管理工作流程提供了全面的质量保证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.60
自引率
19.00%
发文量
331
审稿时长
3 months
期刊介绍: Journal of Applied Clinical Medical Physics is an international Open Access publication dedicated to clinical medical physics. JACMP welcomes original contributions dealing with all aspects of medical physics from scientists working in the clinical medical physics around the world. JACMP accepts only online submission. JACMP will publish: -Original Contributions: Peer-reviewed, investigations that represent new and significant contributions to the field. Recommended word count: up to 7500. -Review Articles: Reviews of major areas or sub-areas in the field of clinical medical physics. These articles may be of any length and are peer reviewed. -Technical Notes: These should be no longer than 3000 words, including key references. -Letters to the Editor: Comments on papers published in JACMP or on any other matters of interest to clinical medical physics. These should not be more than 1250 (including the literature) and their publication is only based on the decision of the editor, who occasionally asks experts on the merit of the contents. -Book Reviews: The editorial office solicits Book Reviews. -Announcements of Forthcoming Meetings: The Editor may provide notice of forthcoming meetings, course offerings, and other events relevant to clinical medical physics. -Parallel Opposed Editorial: We welcome topics relevant to clinical practice and medical physics profession. The contents can be controversial debate or opposed aspects of an issue. One author argues for the position and the other against. Each side of the debate contains an opening statement up to 800 words, followed by a rebuttal up to 500 words. Readers interested in participating in this series should contact the moderator with a proposed title and a short description of the topic
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书