Anatomy-prior-guided and scan-aware 3D segmentation of the pediatric pancreas in CT images.

IF 3.1 3区 医学 Q2 ENGINEERING, BIOMEDICAL
Wenbo Xiong, Nian Liu, Hanran Yan, Yan Liu
{"title":"Anatomy-prior-guided and scan-aware 3D segmentation of the pediatric pancreas in CT images.","authors":"Wenbo Xiong, Nian Liu, Hanran Yan, Yan Liu","doi":"10.1088/1361-6560/aea8c5","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>Pediatric pancreas CT segmentation is challenging because developmental anatomy and scan-protocol variability jointly affect organ size, image appearance, and boundary visibility. This study evaluated whether explicitly incorporating anatomy-related and scan-related case-level descriptors could improve pediatric pancreas segmentation relative to an image-only baseline.<i>Approach.</i>We developed APSC-Net, an anatomy-prior-guided and scan-aware 3D segmentation framework based on SegResNet. Structured anatomy-related and scan-related descriptors were encoded as separate context vectors and injected through bottleneck anatomy-prior guidance and decoder-stage low-rank FiLM modulation. The model was trained and internally tested on GE pediatric CT cases, then evaluated without retraining on a held-out Siemens subset in a cross-vendor evaluation within the same cohort and institution.<i>Main results.</i>On the full held-out GE test set, APSC-Net improved the mean dice similarity coefficient (DSC) from 0.665 to 0.770 and reduced the 95% Hausdorff distance (HD95) from 22.2 to 11.6 mm compared with an image-only SegResNet baseline. Stratified analysis showed DSC gains across pediatric age groups, including the youngest subgroup (0.718-0.751 for 0-5 years), and across exposure-stage strata. In the GE stream ablation, the full and scan-only configurations performed similarly. In secondary testing on held-out Siemens cases, the full model achieved lower average symmetric surface distance (ASSD) than either single-stream variant and achieved the lowest HD95 and ASSD among the compared methods, while age-group domain-regularized baselines remained competitive in DSC.<i>Significance.</i>On the evaluated cohorts, APSC-Net achieved lower boundary-distance errors than the image-only SegResNet baseline. The findings support further evaluation of case-level metadata conditioning for pediatric imaging tasks affected by developmental and acquisition-related variability.</p>","PeriodicalId":20185,"journal":{"name":"Physics in medicine and biology","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2026-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics in medicine and biology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6560/aea8c5","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective.Pediatric pancreas CT segmentation is challenging because developmental anatomy and scan-protocol variability jointly affect organ size, image appearance, and boundary visibility. This study evaluated whether explicitly incorporating anatomy-related and scan-related case-level descriptors could improve pediatric pancreas segmentation relative to an image-only baseline.Approach.We developed APSC-Net, an anatomy-prior-guided and scan-aware 3D segmentation framework based on SegResNet. Structured anatomy-related and scan-related descriptors were encoded as separate context vectors and injected through bottleneck anatomy-prior guidance and decoder-stage low-rank FiLM modulation. The model was trained and internally tested on GE pediatric CT cases, then evaluated without retraining on a held-out Siemens subset in a cross-vendor evaluation within the same cohort and institution.Main results.On the full held-out GE test set, APSC-Net improved the mean dice similarity coefficient (DSC) from 0.665 to 0.770 and reduced the 95% Hausdorff distance (HD95) from 22.2 to 11.6 mm compared with an image-only SegResNet baseline. Stratified analysis showed DSC gains across pediatric age groups, including the youngest subgroup (0.718-0.751 for 0-5 years), and across exposure-stage strata. In the GE stream ablation, the full and scan-only configurations performed similarly. In secondary testing on held-out Siemens cases, the full model achieved lower average symmetric surface distance (ASSD) than either single-stream variant and achieved the lowest HD95 and ASSD among the compared methods, while age-group domain-regularized baselines remained competitive in DSC.Significance.On the evaluated cohorts, APSC-Net achieved lower boundary-distance errors than the image-only SegResNet baseline. The findings support further evaluation of case-level metadata conditioning for pediatric imaging tasks affected by developmental and acquisition-related variability.

儿童胰腺CT图像的解剖先验引导和扫描感知三维分割。
目的:儿童胰腺CT分割具有挑战性,因为发育解剖学和扫描方案的可变性共同影响器官大小、图像外观和边界可见性。本研究评估了是否明确结合解剖相关和扫描相关的病例级描述符可以改善儿童胰腺分割相对于仅图像基线。方法:我们基于SegResNet开发了APSC-Net,解剖先验引导和扫描感知的3D分割框架。结构化解剖相关描述符和扫描相关描述符被编码为单独的上下文向量,并通过瓶颈解剖-先验引导和解码-低秩FiLM调制注入。该模型在GE儿科ct病例中进行了培训和内部测试,然后在同一队列和机构的跨供应商评估中,在不进行再培训的情况下对西门子子集进行了评估。主要结果:在完整的GE测试集上,与仅图像的SegResNet基线相比,APSC-Net将平均Dice相似系数(DSC)从0.665提高到0.770,并将95% Hausdorff距离(HD95)从22.2降低到11.6 mm。分层分析显示,DSC差异跨越儿童年龄组,包括最年轻的亚组(0 -5岁为0.718至0.751),并跨越暴露阶段。在GE流消融中,全扫描和仅扫描配置的表现相似。在西门子病例的二次测试中,全模型获得的ASSD低于单流变体,并且在比较的方法中获得了最低的thd95和ASSD,而年龄组域正则化基线在DSC中仍然具有竞争力。意义:在评估的队列中,apsc - net的边界距离误差低于仅图像的SegResNet基线。研究结果支持进一步评估受发育和获取相关变异性影响的儿科成像任务的病例级元数据条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Physics in medicine and biology
Physics in medicine and biology 医学-工程:生物医学
CiteScore
6.50
自引率
14.30%
发文量
409
审稿时长
2 months
期刊介绍: The development and application of theoretical, computational and experimental physics to medicine, physiology and biology. Topics covered are: therapy physics (including ionizing and non-ionizing radiation); biomedical imaging (e.g. x-ray, magnetic resonance, ultrasound, optical and nuclear imaging); image-guided interventions; image reconstruction and analysis (including kinetic modelling); artificial intelligence in biomedical physics and analysis; nanoparticles in imaging and therapy; radiobiology; radiation protection and patient dose monitoring; radiation dosimetry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书