{"title":"Anatomy-prior-guided and scan-aware 3D segmentation of the pediatric pancreas in CT images.","authors":"Wenbo Xiong, Nian Liu, Hanran Yan, Yan Liu","doi":"10.1088/1361-6560/aea8c5","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>Pediatric pancreas CT segmentation is challenging because developmental anatomy and scan-protocol variability jointly affect organ size, image appearance, and boundary visibility. This study evaluated whether explicitly incorporating anatomy-related and scan-related case-level descriptors could improve pediatric pancreas segmentation relative to an image-only baseline.<i>Approach.</i>We developed APSC-Net, an anatomy-prior-guided and scan-aware 3D segmentation framework based on SegResNet. Structured anatomy-related and scan-related descriptors were encoded as separate context vectors and injected through bottleneck anatomy-prior guidance and decoder-stage low-rank FiLM modulation. The model was trained and internally tested on GE pediatric CT cases, then evaluated without retraining on a held-out Siemens subset in a cross-vendor evaluation within the same cohort and institution.<i>Main results.</i>On the full held-out GE test set, APSC-Net improved the mean dice similarity coefficient (DSC) from 0.665 to 0.770 and reduced the 95% Hausdorff distance (HD95) from 22.2 to 11.6 mm compared with an image-only SegResNet baseline. Stratified analysis showed DSC gains across pediatric age groups, including the youngest subgroup (0.718-0.751 for 0-5 years), and across exposure-stage strata. In the GE stream ablation, the full and scan-only configurations performed similarly. In secondary testing on held-out Siemens cases, the full model achieved lower average symmetric surface distance (ASSD) than either single-stream variant and achieved the lowest HD95 and ASSD among the compared methods, while age-group domain-regularized baselines remained competitive in DSC.<i>Significance.</i>On the evaluated cohorts, APSC-Net achieved lower boundary-distance errors than the image-only SegResNet baseline. The findings support further evaluation of case-level metadata conditioning for pediatric imaging tasks affected by developmental and acquisition-related variability.</p>","PeriodicalId":20185,"journal":{"name":"Physics in medicine and biology","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2026-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics in medicine and biology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6560/aea8c5","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Objective.Pediatric pancreas CT segmentation is challenging because developmental anatomy and scan-protocol variability jointly affect organ size, image appearance, and boundary visibility. This study evaluated whether explicitly incorporating anatomy-related and scan-related case-level descriptors could improve pediatric pancreas segmentation relative to an image-only baseline.Approach.We developed APSC-Net, an anatomy-prior-guided and scan-aware 3D segmentation framework based on SegResNet. Structured anatomy-related and scan-related descriptors were encoded as separate context vectors and injected through bottleneck anatomy-prior guidance and decoder-stage low-rank FiLM modulation. The model was trained and internally tested on GE pediatric CT cases, then evaluated without retraining on a held-out Siemens subset in a cross-vendor evaluation within the same cohort and institution.Main results.On the full held-out GE test set, APSC-Net improved the mean dice similarity coefficient (DSC) from 0.665 to 0.770 and reduced the 95% Hausdorff distance (HD95) from 22.2 to 11.6 mm compared with an image-only SegResNet baseline. Stratified analysis showed DSC gains across pediatric age groups, including the youngest subgroup (0.718-0.751 for 0-5 years), and across exposure-stage strata. In the GE stream ablation, the full and scan-only configurations performed similarly. In secondary testing on held-out Siemens cases, the full model achieved lower average symmetric surface distance (ASSD) than either single-stream variant and achieved the lowest HD95 and ASSD among the compared methods, while age-group domain-regularized baselines remained competitive in DSC.Significance.On the evaluated cohorts, APSC-Net achieved lower boundary-distance errors than the image-only SegResNet baseline. The findings support further evaluation of case-level metadata conditioning for pediatric imaging tasks affected by developmental and acquisition-related variability.
期刊介绍:
The development and application of theoretical, computational and experimental physics to medicine, physiology and biology. Topics covered are: therapy physics (including ionizing and non-ionizing radiation); biomedical imaging (e.g. x-ray, magnetic resonance, ultrasound, optical and nuclear imaging); image-guided interventions; image reconstruction and analysis (including kinetic modelling); artificial intelligence in biomedical physics and analysis; nanoparticles in imaging and therapy; radiobiology; radiation protection and patient dose monitoring; radiation dosimetry