A systematic pipeline for evaluating factors affecting radar-based microwave breast imaging quality.

IF 2 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Eleonora Razzicchia, Yunxiao Zhang, Anthony Gracioppo, Ali Farshkaran, Sibi C Shanmugavel, Shwetadwip Chowdhury, Emily Porter
{"title":"A systematic pipeline for evaluating factors affecting radar-based microwave breast imaging quality.","authors":"Eleonora Razzicchia, Yunxiao Zhang, Anthony Gracioppo, Ali Farshkaran, Sibi C Shanmugavel, Shwetadwip Chowdhury, Emily Porter","doi":"10.1088/2057-1976/aea856","DOIUrl":null,"url":null,"abstract":"<p><p>Microwave imaging (MWI) has emerged as a promising non-ionizing, cost-effective technique for breast cancer detection. However, the influence of key system design choices remains poorly characterized. This study aims to systematically investigate how antenna array geometry, tumor characteristics, and tissue dielectric properties influence radar-based image reconstruction using a robust computational pipeline. A total of 575 different scenarios were simulated and analyzed, combining 25 distinct breast models with varying tumor configurations and 23 antenna configurations (including 20 randomly selected antenna subsets and 3 uniform arrays). The breast models included one or two tumors with varying radii, embedded in backgrounds with different dielectric properties. Quantitative metrics such as signal-to-noise ratio (SNR), signal-to-mean ratio, localization error, and separation error were used to consistently evaluate the reconstructed images. Additionally, a proof-of-concept experimental study using a laboratory MWI prototype was also conducted to demonstrate the applicability of the proposed pipeline to measured data. Simulation results show that image quality improves with increasing antenna count, while, among arrays with the same number of elements, uniform and symmetric geometries achieve higher average SNR than asymmetric configurations. Tissue relative permittivity and tumor size show limited correlation with the image quality metrics, whereas tumor location within the phantom significantly affects localization accuracy. The experimental proof of concept further demonstrated the capability of the proposed pipeline to compare different types of reconstruction algorithms using the same quantitative image quality metrics. These findings provide quantitative insights into the influence of antenna array design on breast MWI performance and demonstrate the value of systematic simulation-based evaluation frameworks. The proposed methodology can support the optimization of antenna array layouts and facilitate the development of more effective MWI systems prior to clinical translation.</p>","PeriodicalId":8896,"journal":{"name":"Biomedical Physics & Engineering Express","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2026-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13643835/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Physics & Engineering Express","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2057-1976/aea856","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Microwave imaging (MWI) has emerged as a promising non-ionizing, cost-effective technique for breast cancer detection. However, the influence of key system design choices remains poorly characterized. This study aims to systematically investigate how antenna array geometry, tumor characteristics, and tissue dielectric properties influence radar-based image reconstruction using a robust computational pipeline. A total of 575 different scenarios were simulated and analyzed, combining 25 distinct breast models with varying tumor configurations and 23 antenna configurations (including 20 randomly selected antenna subsets and 3 uniform arrays). The breast models included one or two tumors with varying radii, embedded in backgrounds with different dielectric properties. Quantitative metrics such as signal-to-noise ratio (SNR), signal-to-mean ratio, localization error, and separation error were used to consistently evaluate the reconstructed images. Additionally, a proof-of-concept experimental study using a laboratory MWI prototype was also conducted to demonstrate the applicability of the proposed pipeline to measured data. Simulation results show that image quality improves with increasing antenna count, while, among arrays with the same number of elements, uniform and symmetric geometries achieve higher average SNR than asymmetric configurations. Tissue relative permittivity and tumor size show limited correlation with the image quality metrics, whereas tumor location within the phantom significantly affects localization accuracy. The experimental proof of concept further demonstrated the capability of the proposed pipeline to compare different types of reconstruction algorithms using the same quantitative image quality metrics. These findings provide quantitative insights into the influence of antenna array design on breast MWI performance and demonstrate the value of systematic simulation-based evaluation frameworks. The proposed methodology can support the optimization of antenna array layouts and facilitate the development of more effective MWI systems prior to clinical translation.

基于雷达的微波乳房成像质量影响因素的系统评估管道。
微波成像(MWI)已成为一种很有前途的非电离、成本效益高的乳腺癌检测技术。然而,关键系统设计选择的影响仍然缺乏特征。本研究旨在系统地研究天线阵列几何形状、肿瘤特征和组织介电特性如何影响使用鲁棒计算管道的基于雷达的图像重建。共模拟和分析了575种不同的情况,结合25种不同的乳房模型,不同的肿瘤结构和23种天线配置(包括20个随机选择的天线子集和3个均匀阵列)。乳房模型包括一个或两个不同半径的肿瘤,嵌入在具有不同介电特性的背景中。采用信噪比(SNR)、信均比(SMR)、定位误差和分离误差等定量指标对重建图像进行一致性评价。此外,利用实验室MWI原型进行了概念验证实验研究,以验证所提出的管道对测量数据的适用性。仿真结果表明,随着天线数量的增加,图像质量得到改善,而在相同单元数量的阵列中,均匀和对称几何结构的平均信噪比高于非对称几何结构。组织相对介电常数和肿瘤大小与图像质量指标的相关性有限,而肿瘤在幻象中的位置显著影响定位精度。概念的实验验证进一步证明了所提出的管道使用相同的定量图像质量指标来比较不同类型的重建算法的能力。这些发现为天线阵列设计对乳腺MWI性能的影响提供了定量见解,并证明了基于系统仿真的评估框架的价值。所提出的方法可以支持天线阵列布局的优化,并促进在临床转化之前开发更有效的MWI系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomedical Physics & Engineering Express
Biomedical Physics & Engineering Express RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.80
自引率
0.00%
发文量
153
期刊介绍: BPEX is an inclusive, international, multidisciplinary journal devoted to publishing new research on any application of physics and/or engineering in medicine and/or biology. Characterized by a broad geographical coverage and a fast-track peer-review process, relevant topics include all aspects of biophysics, medical physics and biomedical engineering. Papers that are almost entirely clinical or biological in their focus are not suitable. The journal has an emphasis on publishing interdisciplinary work and bringing research fields together, encompassing experimental, theoretical and computational work.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书