{"title":"Motion correction algorithm improves right coronary artery image quality at heart rates > 75 bpm in non-ECG-gated coronary CT angiography","authors":"Meiqi Wang, Li Tao, Wen Li, YouHong Cao, Hao Wu, Zhiwei Zhang","doi":"10.1002/acm2.70803","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Motion artifacts caused by cardiac pulsation remain a major technical challenge in coronary CT angiography (CCTA). Although an advanced cardiac motion correction (CMC) algorithm has been developed and successfully implemented in clinical practice, the effectiveness of this algorithm in improving coronary image quality in clinical settings has not yet been fully investigated.</p>\n </section>\n \n <section>\n \n <h3> Purpose</h3>\n \n <p>To evaluate the impact and clinical value of a motion correction algorithm on image quality in non-ECG-gated CCTA.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>We retrospectively enrolled 76 patients who underwent CCTA for suspected coronary artery disease. Based on the mean heart rate (HR) recorded during scanning, patients were divided into three groups: low HR (HR ≤ 60 bpm), intermediate HR (60 < HR < 75 bpm), and high HR (HR ≥ 75 bpm). All images were reconstructed using both standard algorithm (STD) and CMC algorithms. The performance of STD and CMC was compared across different HR conditions in terms of subjective (4-point Likert scale, interpretability) and objective image quality (signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and vessel sharpness).</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>At high HRs, the difference in subjective image quality of the right coronary artery (RCA) between STD and CMC reached statistical significance (<i>p</i> < 0.05). Compared with STD, CMC significantly improved the interpretability of the RCA at high HRs (<i>p</i> < 0.001). No statistically significant differences were observed between the two algorithms in terms of SNR or CNR (<i>p</i> > 0.05). However, at high HRs, CMC was significantly superior to STD with respect to vessel sharpness of the RCA (<i>p</i> < 0.001).</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The CMC improves image quality in CCTA, with particularly notable benefits for the RCA under high HR conditions.</p>\n </section>\n </div>","PeriodicalId":14989,"journal":{"name":"Journal of Applied Clinical Medical Physics","volume":"27 9","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2026-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13578101/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Clinical Medical Physics","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/acm2.70803","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Motion artifacts caused by cardiac pulsation remain a major technical challenge in coronary CT angiography (CCTA). Although an advanced cardiac motion correction (CMC) algorithm has been developed and successfully implemented in clinical practice, the effectiveness of this algorithm in improving coronary image quality in clinical settings has not yet been fully investigated.
Purpose
To evaluate the impact and clinical value of a motion correction algorithm on image quality in non-ECG-gated CCTA.
Methods
We retrospectively enrolled 76 patients who underwent CCTA for suspected coronary artery disease. Based on the mean heart rate (HR) recorded during scanning, patients were divided into three groups: low HR (HR ≤ 60 bpm), intermediate HR (60 < HR < 75 bpm), and high HR (HR ≥ 75 bpm). All images were reconstructed using both standard algorithm (STD) and CMC algorithms. The performance of STD and CMC was compared across different HR conditions in terms of subjective (4-point Likert scale, interpretability) and objective image quality (signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and vessel sharpness).
Results
At high HRs, the difference in subjective image quality of the right coronary artery (RCA) between STD and CMC reached statistical significance (p < 0.05). Compared with STD, CMC significantly improved the interpretability of the RCA at high HRs (p < 0.001). No statistically significant differences were observed between the two algorithms in terms of SNR or CNR (p > 0.05). However, at high HRs, CMC was significantly superior to STD with respect to vessel sharpness of the RCA (p < 0.001).
Conclusions
The CMC improves image quality in CCTA, with particularly notable benefits for the RCA under high HR conditions.
期刊介绍:
Journal of Applied Clinical Medical Physics is an international Open Access publication dedicated to clinical medical physics. JACMP welcomes original contributions dealing with all aspects of medical physics from scientists working in the clinical medical physics around the world. JACMP accepts only online submission.
JACMP will publish:
-Original Contributions: Peer-reviewed, investigations that represent new and significant contributions to the field. Recommended word count: up to 7500.
-Review Articles: Reviews of major areas or sub-areas in the field of clinical medical physics. These articles may be of any length and are peer reviewed.
-Technical Notes: These should be no longer than 3000 words, including key references.
-Letters to the Editor: Comments on papers published in JACMP or on any other matters of interest to clinical medical physics. These should not be more than 1250 (including the literature) and their publication is only based on the decision of the editor, who occasionally asks experts on the merit of the contents.
-Book Reviews: The editorial office solicits Book Reviews.
-Announcements of Forthcoming Meetings: The Editor may provide notice of forthcoming meetings, course offerings, and other events relevant to clinical medical physics.
-Parallel Opposed Editorial: We welcome topics relevant to clinical practice and medical physics profession. The contents can be controversial debate or opposed aspects of an issue. One author argues for the position and the other against. Each side of the debate contains an opening statement up to 800 words, followed by a rebuttal up to 500 words. Readers interested in participating in this series should contact the moderator with a proposed title and a short description of the topic