Contrast-enhanced ultrasound for differentiating benign from malignant Breast Imaging Reporting and Data System 4a breast lesions: a prospective diagnostic accuracy study.

IF 1.9 3区 医学 Q3 SURGERY
Gland surgery Pub Date : 2026-08-31 Epub Date: 2026-07-07 DOI:10.21037/gs-2026-0315
Liping Fan, Na Yuan, Fang Qi, Wentao Qu, Jinhui Zhang, Xiaomei Tian, Yaning Kang
{"title":"Contrast-enhanced ultrasound for differentiating benign from malignant Breast Imaging Reporting and Data System 4a breast lesions: a prospective diagnostic accuracy study.","authors":"Liping Fan, Na Yuan, Fang Qi, Wentao Qu, Jinhui Zhang, Xiaomei Tian, Yaning Kang","doi":"10.21037/gs-2026-0315","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Breast Imaging Reporting and Data System (BI-RADS) 4a breast lesions are considered low suspicion for malignancy (2-10%), yet current guidelines recommend biopsy for definitive diagnosis, leading to a high rate of unnecessary invasive procedures. Contrast-enhanced ultrasound (CEUS) provides real-time microvascular perfusion information that may improve risk stratification in this indeterminate category. This study aimed to evaluate the diagnostic performance of CEUS in differentiating benign from malignant BI-RADS 4a lesions, with a focus on its potential to reduce avoidable biopsies.</p><p><strong>Methods: </strong>In this prospective diagnostic study, consecutive patients with BI-RADS 4a lesions identified on conventional ultrasound underwent CEUS examination using a sulfur-hexafluoride microbubble contrast agent. CEUS cine loops were independently reviewed by two blinded readers. Lesions were classified as CEUS-positive (suspicious for malignancy) if they exhibited ≥2 predefined malignant perfusion features (e.g., heterogeneous hyper-enhancement, centripetal filling, perfusion defects, fast wash-in/wash-out). Histopathology from biopsy or surgery served as the reference standard. Diagnostic accuracy metrics-sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and area under the receiver operating characteristic curve (AUC)-were calculated.</p><p><strong>Results: </strong>A total of 149 BI-RADS 4a lesions were included. Histopathology revealed 129 benign and 20 malignant/high-risk lesions. CEUS demonstrated a sensitivity of 85.0% [95% confidence interval (CI): 62.1-96.8%], specificity of 89.9% (95% CI: 83.3-94.6%), PPV of 47.2% (32.9-62.0%), and NPV of 98.2% (95% CI: 93.8-99.6%). The overall accuracy was 89.3% (95% CI: 83.2-93.7%), with an AUC of 0.88 (95% CI: 0.81-0.94). Malignant lesions showed significantly higher frequencies of heterogeneous hyper-enhancement, centripetal perfusion, perfusion defects, and fast wash-in/wash-out kinetics (all P<0.001). Inter-observer agreement for CEUS classification was substantial (κ=0.76).</p><p><strong>Conclusions: </strong>CEUS exhibits high diagnostic performance, especially a high NPV, in the evaluation of BI-RADS 4a breast lesions. It can reliably identify a subset of lesions with a very low probability of malignancy, suggesting that CEUS may help identify a subset of patients in whom immediate biopsy could be considered for deferral within a shared decision-making framework, though prospective validation in larger cohorts is needed. These findings support the integration of CEUS as a valuable adjunctive triage tool to reduce unnecessary biopsies in low-suspicion breast lesions.</p>","PeriodicalId":12760,"journal":{"name":"Gland surgery","volume":"15 8","pages":"235"},"PeriodicalIF":1.9000,"publicationDate":"2026-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13561622/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gland surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21037/gs-2026-0315","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/7 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Breast Imaging Reporting and Data System (BI-RADS) 4a breast lesions are considered low suspicion for malignancy (2-10%), yet current guidelines recommend biopsy for definitive diagnosis, leading to a high rate of unnecessary invasive procedures. Contrast-enhanced ultrasound (CEUS) provides real-time microvascular perfusion information that may improve risk stratification in this indeterminate category. This study aimed to evaluate the diagnostic performance of CEUS in differentiating benign from malignant BI-RADS 4a lesions, with a focus on its potential to reduce avoidable biopsies.

Methods: In this prospective diagnostic study, consecutive patients with BI-RADS 4a lesions identified on conventional ultrasound underwent CEUS examination using a sulfur-hexafluoride microbubble contrast agent. CEUS cine loops were independently reviewed by two blinded readers. Lesions were classified as CEUS-positive (suspicious for malignancy) if they exhibited ≥2 predefined malignant perfusion features (e.g., heterogeneous hyper-enhancement, centripetal filling, perfusion defects, fast wash-in/wash-out). Histopathology from biopsy or surgery served as the reference standard. Diagnostic accuracy metrics-sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and area under the receiver operating characteristic curve (AUC)-were calculated.

Results: A total of 149 BI-RADS 4a lesions were included. Histopathology revealed 129 benign and 20 malignant/high-risk lesions. CEUS demonstrated a sensitivity of 85.0% [95% confidence interval (CI): 62.1-96.8%], specificity of 89.9% (95% CI: 83.3-94.6%), PPV of 47.2% (32.9-62.0%), and NPV of 98.2% (95% CI: 93.8-99.6%). The overall accuracy was 89.3% (95% CI: 83.2-93.7%), with an AUC of 0.88 (95% CI: 0.81-0.94). Malignant lesions showed significantly higher frequencies of heterogeneous hyper-enhancement, centripetal perfusion, perfusion defects, and fast wash-in/wash-out kinetics (all P<0.001). Inter-observer agreement for CEUS classification was substantial (κ=0.76).

Conclusions: CEUS exhibits high diagnostic performance, especially a high NPV, in the evaluation of BI-RADS 4a breast lesions. It can reliably identify a subset of lesions with a very low probability of malignancy, suggesting that CEUS may help identify a subset of patients in whom immediate biopsy could be considered for deferral within a shared decision-making framework, though prospective validation in larger cohorts is needed. These findings support the integration of CEUS as a valuable adjunctive triage tool to reduce unnecessary biopsies in low-suspicion breast lesions.

对比增强超声鉴别乳腺良恶性影像报告和数据系统4a乳腺病变:一项前瞻性诊断准确性研究
背景:乳腺成像报告和数据系统(BI-RADS) 4a级乳腺病变被认为是低怀疑恶性肿瘤(2-10%),但目前的指南建议活检进行明确诊断,导致不必要的侵入性手术的高发率。超声造影(CEUS)提供实时微血管灌注信息,可能改善这种不确定类别的风险分层。本研究旨在评估超声造影在区分BI-RADS 4a良恶性病变中的诊断性能,重点关注其减少可避免的活检的潜力。方法:在这项前瞻性诊断研究中,连续使用六氟化硫微泡造影剂对常规超声发现BI-RADS 4a病变的患者进行超声造影检查。超声造影电影循环由两位盲法读者独立评价。如果病变表现出≥2个预定义的恶性灌注特征(如非均匀超增强、向心填充、灌注缺陷、快速洗入/洗出),则归为超声造影阳性(可疑恶性)。组织病理学活检或手术作为参考标准。计算诊断准确性指标——敏感性、特异性、阳性预测值(PPV)、阴性预测值(NPV)、准确性和受试者工作特征曲线下面积(AUC)。结果:共纳入149个BI-RADS 4a病变。组织病理学显示良性病变129例,恶性/高危病变20例。CEUS的敏感性为85.0%[95%可信区间(CI): 62.1-96.8%],特异性为89.9% (95% CI: 83.3-94.6%), PPV为47.2% (32.9-62.0%),NPV为98.2% (95% CI: 93.8-99.6%)。总体准确度为89.3% (95% CI: 83.2 ~ 93.7%), AUC为0.88 (95% CI: 0.81 ~ 0.94)。恶性病变表现为异质性超增强、向心灌注、灌注缺损、快速冲洗/冲洗动力学(均p)。结论:超声造影对BI-RADS 4a乳腺病变具有较高的诊断价值,尤其是NPV值较高。它可以可靠地识别出恶性肿瘤概率极低的病变亚群,这表明超声造影可能有助于识别出在共同决策框架内可以考虑延迟立即活检的患者亚群,尽管需要在更大的队列中进行前瞻性验证。这些发现支持超声造影作为一种有价值的辅助分诊工具的整合,以减少对低怀疑性乳腺病变的不必要的活检。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Gland surgery
Gland surgery Medicine-Surgery
CiteScore
3.60
自引率
0.00%
发文量
113
期刊介绍: Gland Surgery (Gland Surg; GS, Print ISSN 2227-684X; Online ISSN 2227-8575) being indexed by PubMed/PubMed Central, is an open access, peer-review journal launched at May of 2012, published bio-monthly since February 2015.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书