Use of a Large-Caliber Endoscopic Sheath to Prevent Device Deflection During EUS-Guided Antegrade Stone Removal

IF 3.6 2区 医学 Q1 GASTROENTEROLOGY & HEPATOLOGY
Kenichi Haneda, Akihisa Kato, Michihiro Yoshida
{"title":"Use of a Large-Caliber Endoscopic Sheath to Prevent Device Deflection During EUS-Guided Antegrade Stone Removal","authors":"Kenichi Haneda,&nbsp;Akihisa Kato,&nbsp;Michihiro Yoshida","doi":"10.1111/den.70273","DOIUrl":null,"url":null,"abstract":"<p>Endoscopic access to the duodenal papilla can be difficult in patients who have undergone postoperative intestinal reconstruction. EUS-guided antegrade biliary intervention (EUS-AI) via a trans-endosonographically created route (trans-ESCR) is widely accepted as an alternative method for stone removal [<span>1, 2</span>]; however, the tortuosity of the intrahepatic bile duct often causes device deflection. As a result, force transmission is poor, making it difficult to push stones out of the papilla.</p><p>The patient was an 86-year-old woman who had undergone distal gastrectomy and Billroth II reconstruction for gastric cancer. She developed common bile duct stone cholangitis (Figure 1a). Transpapillary biliary drainage using a double balloon was attempted, but reaching the papilla was difficult, so EUS-guided hepaticogastrostomy (EUS-HGS) was performed (Figure 1b). Subsequently, stone removal was attempted antegrade via the trans-ESCR. A 0.035-in. guidewire was guided to the duodenum, and antegrade papillary balloon dilation was performed. The subsequently inserted balloon catheter for stone removal became significantly deflected within the intrahepatic bile duct. Due to this loss of axial force, the catheter was unable to push the stone into the duodenum (Figure 2a, Video 1).</p><p>To solve this problem, we used a large-caliber version of EndoSheather (Piolax Inc., Yokohama, Japan) (Figure 2b) [<span>3-5</span>]. By advancing the sheath over a guidewire into the bile duct, the sheath served as a stable conduit for the balloon catheter. The sheath effectively prevented device deflection and ensured optimal force transmission, allowing the catheter to smoothly pass through the papilla and successfully remove the stone (Figure 2c).</p><p>Therefore, the large-caliber sheath is highly effective for various trans-ESCR treatments, including intrahepatic stones. Once a stone is moved into the distal bile duct, the sheath's function of preventing device bending plays an indispensable role in reliable transpapillary removal. This ensures optimal force transmission regardless of the initial stone location.</p><p>The authors have nothing to report.</p><p>The authors declare no conflicts of interest.</p><p>The data that support the findings of this study are available on request from the corresponding author. The data are not publicly available due to privacy or ethical restrictions.</p>","PeriodicalId":159,"journal":{"name":"Digestive Endoscopy","volume":"38 9","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2026-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13550790/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digestive Endoscopy","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/den.70273","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Endoscopic access to the duodenal papilla can be difficult in patients who have undergone postoperative intestinal reconstruction. EUS-guided antegrade biliary intervention (EUS-AI) via a trans-endosonographically created route (trans-ESCR) is widely accepted as an alternative method for stone removal [1, 2]; however, the tortuosity of the intrahepatic bile duct often causes device deflection. As a result, force transmission is poor, making it difficult to push stones out of the papilla.

The patient was an 86-year-old woman who had undergone distal gastrectomy and Billroth II reconstruction for gastric cancer. She developed common bile duct stone cholangitis (Figure 1a). Transpapillary biliary drainage using a double balloon was attempted, but reaching the papilla was difficult, so EUS-guided hepaticogastrostomy (EUS-HGS) was performed (Figure 1b). Subsequently, stone removal was attempted antegrade via the trans-ESCR. A 0.035-in. guidewire was guided to the duodenum, and antegrade papillary balloon dilation was performed. The subsequently inserted balloon catheter for stone removal became significantly deflected within the intrahepatic bile duct. Due to this loss of axial force, the catheter was unable to push the stone into the duodenum (Figure 2a, Video 1).

To solve this problem, we used a large-caliber version of EndoSheather (Piolax Inc., Yokohama, Japan) (Figure 2b) [3-5]. By advancing the sheath over a guidewire into the bile duct, the sheath served as a stable conduit for the balloon catheter. The sheath effectively prevented device deflection and ensured optimal force transmission, allowing the catheter to smoothly pass through the papilla and successfully remove the stone (Figure 2c).

Therefore, the large-caliber sheath is highly effective for various trans-ESCR treatments, including intrahepatic stones. Once a stone is moved into the distal bile duct, the sheath's function of preventing device bending plays an indispensable role in reliable transpapillary removal. This ensures optimal force transmission regardless of the initial stone location.

The authors have nothing to report.

The authors declare no conflicts of interest.

The data that support the findings of this study are available on request from the corresponding author. The data are not publicly available due to privacy or ethical restrictions.

使用大口径内窥镜护套防止在eus引导下顺行结石移除过程中设备偏转。
内镜下进入十二指肠乳头可能是困难的患者术后肠重建。eus引导下经超声创建的顺行胆道介入治疗(EUS-AI) (trans-ESCR)被广泛接受为结石清除的替代方法[1,2];然而,肝内胆管的弯曲常常导致装置偏转。因此,力的传递很差,使得很难将结石从乳头中推出。患者为86岁女性,因胃癌行远端胃切除术和Billroth II重建。她出现胆总管结石性胆管炎(图1a)。尝试使用双球囊进行经乳头胆道引流,但难以到达乳头,因此进行了eus引导的肝胃造口术(EUS-HGS)(图1b)。随后,试图通过跨escr顺行清除结石。——0.035。导丝引导至十二指肠,行顺行乳头球囊扩张术。随后插入的球囊导管在肝内胆管内明显偏转。由于轴向力的损失,导管无法将结石推入十二指肠(图2a,视频1)。为了解决这个问题,我们使用了大口径的EndoSheather (Piolax Inc., Yokohama, Japan)(图2b)[3-5]。通过导丝推进鞘进入胆管,鞘为球囊导管提供了一个稳定的导管。鞘有效防止了装置偏转,保证了最佳的力传递,使导管顺利通过乳头,成功取出结石(图2c)。因此,大口径鞘对于包括肝内结石在内的各种跨escr治疗非常有效。一旦结石进入远端胆管,护套防止装置弯曲的功能在可靠的经乳头切除中起着不可或缺的作用。无论最初的石头位置如何,这都确保了最佳的力传递。作者没有什么可报告的。作者声明无利益冲突。支持本研究结果的数据可向通讯作者索取。由于隐私或道德限制,这些数据不会公开。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Digestive Endoscopy
Digestive Endoscopy 医学-外科
CiteScore
10.10
自引率
15.10%
发文量
291
审稿时长
6-12 weeks
期刊介绍: Digestive Endoscopy (DEN) is the official journal of the Japan Gastroenterological Endoscopy Society, the Asian Pacific Society for Digestive Endoscopy and the World Endoscopy Organization. Digestive Endoscopy serves as a medium for presenting original articles that offer significant contributions to knowledge in the broad field of endoscopy. The Journal also includes Reviews, Original Articles, How I Do It, Case Reports (only of exceptional interest and novelty are accepted), Letters, Techniques and Images, abstracts and news items that may be of interest to endoscopists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书