Narrowband isotropic magnetic particle imaging with FFL-parallel excitation.

IF 3.1 3区 医学 Q2 ENGINEERING, BIOMEDICAL
Zhongwei Bian, Ziwei Chen, Jie He, Hui Hui, Guang Jia, Yu An, Jie Tian
{"title":"Narrowband isotropic magnetic particle imaging with FFL-parallel excitation.","authors":"Zhongwei Bian, Ziwei Chen, Jie He, Hui Hui, Guang Jia, Yu An, Jie Tian","doi":"10.1088/1361-6560/aea399","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>Magnetic particle imaging (MPI) is an emerging medical imaging technique for high-sensitivity and quantitative visualization of tracer distributions. Narrowband MPI achieves high signal-to-noise ratio (SNR) by selectively detecting a few harmonics. However, in its conventional implementations,the point spread function (PSF) inevitably exhibits negative lobes, which introduce anisotropic resolution and destructive signal superposition.<i>Approach.</i>To address this, we propose a narrowband isotropic MPI system, utilizing the field-free-line (FFL)-parallel excitation (FPE) scanning strategy to eliminate negative lobes. FPE-MPI employs single-channel acquisition with coaxial excitation and receive, applies an excitation field parallel to the FFL while maintaining a constant collinear offset field, and encodes harmonic responses on the projection plane orthogonal to the FFL.<i>Main results.</i>Through simulations and phantom experiments on our in-house scanner, we demonstrate that FPE-MPI eliminates the adverse effects of negative lobes, achieves isotropic imaging, and improves image quality. Compared with conventional narrowband MPI with FFL-orthogonal excitation, FPE-MPI preserves higher SNR in the acquired signals and yields robust reconstructions at low tracer concentrations, with only a modest trade-off in spatial resolution.<i>Significance.</i>FPE-MPI facilitates robust imaging at low tracer doses and provides a feasible scanning strategy for the development of future large field-of-view (FOV) narrowband MPI systems.</p>","PeriodicalId":20185,"journal":{"name":"Physics in medicine and biology","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2026-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics in medicine and biology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6560/aea399","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective.Magnetic particle imaging (MPI) is an emerging medical imaging technique for high-sensitivity and quantitative visualization of tracer distributions. Narrowband MPI achieves high signal-to-noise ratio (SNR) by selectively detecting a few harmonics. However, in its conventional implementations,the point spread function (PSF) inevitably exhibits negative lobes, which introduce anisotropic resolution and destructive signal superposition.Approach.To address this, we propose a narrowband isotropic MPI system, utilizing the field-free-line (FFL)-parallel excitation (FPE) scanning strategy to eliminate negative lobes. FPE-MPI employs single-channel acquisition with coaxial excitation and receive, applies an excitation field parallel to the FFL while maintaining a constant collinear offset field, and encodes harmonic responses on the projection plane orthogonal to the FFL.Main results.Through simulations and phantom experiments on our in-house scanner, we demonstrate that FPE-MPI eliminates the adverse effects of negative lobes, achieves isotropic imaging, and improves image quality. Compared with conventional narrowband MPI with FFL-orthogonal excitation, FPE-MPI preserves higher SNR in the acquired signals and yields robust reconstructions at low tracer concentrations, with only a modest trade-off in spatial resolution.Significance.FPE-MPI facilitates robust imaging at low tracer doses and provides a feasible scanning strategy for the development of future large field-of-view (FOV) narrowband MPI systems.

窄带各向同性磁粒子成像与ffl平行激励。
目的:磁颗粒成像(MPI)是一种新兴的医学成像技术,可对示踪剂分布进行高灵敏度和定量可视化。窄带MPI通过选择性地检测少量谐波来实现高信噪比。然而,在其传统实现中,点扩展函数(PSF)不可避免地呈现负瓣,这引入了各向异性分辨率和破坏性信号叠加方法。为了解决这个问题,我们提出了一个窄带各向同性MPI系统,利用场-自由线(FFL)-平行激励(FPE)扫描策略来消除负叶。FPE-MPI采用同轴激励和接收的单通道采集,施加与FFL平行的激励场,同时保持恒定的共线偏移场,在与FFL正交的投影平面上编码谐波响应。 ;主要结果。通过在我们的内部扫描仪上的模拟和模拟实验,我们证明了FPE-MPI消除了负叶的不利影响,实现了各向同性成像,提高了图像质量。与ffl正交激励的传统窄带MPI相比,FPE-MPI在获取的信号中保留了更高的信噪比,并且在低示踪剂浓度下产生了稳健的重建,仅在空间分辨率上有适度的折衷。& # xD;意义。FPE-MPI有助于低示踪剂剂量下的鲁棒成像,并为未来大视场(FOV)窄带MPI系统的开发提供了可行的扫描策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Physics in medicine and biology
Physics in medicine and biology 医学-工程:生物医学
CiteScore
6.50
自引率
14.30%
发文量
409
审稿时长
2 months
期刊介绍: The development and application of theoretical, computational and experimental physics to medicine, physiology and biology. Topics covered are: therapy physics (including ionizing and non-ionizing radiation); biomedical imaging (e.g. x-ray, magnetic resonance, ultrasound, optical and nuclear imaging); image-guided interventions; image reconstruction and analysis (including kinetic modelling); artificial intelligence in biomedical physics and analysis; nanoparticles in imaging and therapy; radiobiology; radiation protection and patient dose monitoring; radiation dosimetry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书