Shizhuo Li, Unay Dorken Gallastegi, Shohei Fujita, Yuting Chen, Pengcheng Xu, Kwok-Shing Chan, Yangsean Choi, Jiye Kim, Gian Franco Piredda, Tom Hilbert, Jongho Lee, Huihui Ye, Borjan Gagoski, Huafeng Liu, Berkin Bilgic, Yohan Jun
{"title":"Omni-QALAS: Optimized Multiparametric Imaging for Simultaneous $T_{1}$, $T_{2}$ and Myelin Water Mapping.","authors":"Shizhuo Li, Unay Dorken Gallastegi, Shohei Fujita, Yuting Chen, Pengcheng Xu, Kwok-Shing Chan, Yangsean Choi, Jiye Kim, Gian Franco Piredda, Tom Hilbert, Jongho Lee, Huihui Ye, Borjan Gagoski, Huafeng Liu, Berkin Bilgic, Yohan Jun","doi":"10.1109/TBME.2026.3731202","DOIUrl":null,"url":null,"abstract":"<p><p>3D-QALAS enables efficient multi-parametric $T_{\\text{1}}$, $T_{\\text{2}}$, and proton density (PD) mapping in a single scan; however, heuristic parameter selection limits image quality and myelin water fraction (MWF) quantification accuracy. While the subsequently proposed MWF-QALAS sequence improves MWF estimation, it requires an additional readout that prolongs scan time by approximately one minute and lacks precision for short $T_{\\text{1}}$ and $T_{\\text{2}}$ values. To address these limitations, we introduce Omni-QALAS (Optimized Myelin & Neurometric Imaging). The sequence flip angles, $T_{\\text{2}}$ preparation durations, and $T_{\\text{1}}$ recovery gaps are jointly optimized using a self-supervised multilayer perceptron (MLP). The MLP is trained to minimize a Cramér-Rao bound-based loss function subject to explicit total scan time constraints. Integrated with subspace reconstruction, the optimized Omni-QALAS reduces the required number of readouts from six to five compared to MWF-QALAS. This optimization shortens the overall scan time by 16% while yielding higher $T_{\\text{1}}$ and $T_{\\text{2}}$ accuracy alongside improved MWF maps. Simulation, phantom, and in vivo validations demonstrate that the Omni-QALAS protocol provides accurate whole-brain multiparametric quantification at 1 mm isotropic resolution within 5 minutes, with demonstrated feasibility for faster acquisition down to 3 minutes 30 seconds.</p>","PeriodicalId":13245,"journal":{"name":"IEEE Transactions on Biomedical Engineering","volume":"PP ","pages":""},"PeriodicalIF":4.4000,"publicationDate":"2026-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1109/TBME.2026.3731202","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
3D-QALAS enables efficient multi-parametric $T_{\text{1}}$, $T_{\text{2}}$, and proton density (PD) mapping in a single scan; however, heuristic parameter selection limits image quality and myelin water fraction (MWF) quantification accuracy. While the subsequently proposed MWF-QALAS sequence improves MWF estimation, it requires an additional readout that prolongs scan time by approximately one minute and lacks precision for short $T_{\text{1}}$ and $T_{\text{2}}$ values. To address these limitations, we introduce Omni-QALAS (Optimized Myelin & Neurometric Imaging). The sequence flip angles, $T_{\text{2}}$ preparation durations, and $T_{\text{1}}$ recovery gaps are jointly optimized using a self-supervised multilayer perceptron (MLP). The MLP is trained to minimize a Cramér-Rao bound-based loss function subject to explicit total scan time constraints. Integrated with subspace reconstruction, the optimized Omni-QALAS reduces the required number of readouts from six to five compared to MWF-QALAS. This optimization shortens the overall scan time by 16% while yielding higher $T_{\text{1}}$ and $T_{\text{2}}$ accuracy alongside improved MWF maps. Simulation, phantom, and in vivo validations demonstrate that the Omni-QALAS protocol provides accurate whole-brain multiparametric quantification at 1 mm isotropic resolution within 5 minutes, with demonstrated feasibility for faster acquisition down to 3 minutes 30 seconds.
期刊介绍:
IEEE Transactions on Biomedical Engineering contains basic and applied papers dealing with biomedical engineering. Papers range from engineering development in methods and techniques with biomedical applications to experimental and clinical investigations with engineering contributions.