Omni-QALAS: Optimized Multiparametric Imaging for Simultaneous $T_{1}$, $T_{2}$ and Myelin Water Mapping.

IF 4.4 2区 医学 Q2 ENGINEERING, BIOMEDICAL
Shizhuo Li, Unay Dorken Gallastegi, Shohei Fujita, Yuting Chen, Pengcheng Xu, Kwok-Shing Chan, Yangsean Choi, Jiye Kim, Gian Franco Piredda, Tom Hilbert, Jongho Lee, Huihui Ye, Borjan Gagoski, Huafeng Liu, Berkin Bilgic, Yohan Jun
{"title":"Omni-QALAS: Optimized Multiparametric Imaging for Simultaneous $T_{1}$, $T_{2}$ and Myelin Water Mapping.","authors":"Shizhuo Li, Unay Dorken Gallastegi, Shohei Fujita, Yuting Chen, Pengcheng Xu, Kwok-Shing Chan, Yangsean Choi, Jiye Kim, Gian Franco Piredda, Tom Hilbert, Jongho Lee, Huihui Ye, Borjan Gagoski, Huafeng Liu, Berkin Bilgic, Yohan Jun","doi":"10.1109/TBME.2026.3731202","DOIUrl":null,"url":null,"abstract":"<p><p>3D-QALAS enables efficient multi-parametric $T_{\\text{1}}$, $T_{\\text{2}}$, and proton density (PD) mapping in a single scan; however, heuristic parameter selection limits image quality and myelin water fraction (MWF) quantification accuracy. While the subsequently proposed MWF-QALAS sequence improves MWF estimation, it requires an additional readout that prolongs scan time by approximately one minute and lacks precision for short $T_{\\text{1}}$ and $T_{\\text{2}}$ values. To address these limitations, we introduce Omni-QALAS (Optimized Myelin & Neurometric Imaging). The sequence flip angles, $T_{\\text{2}}$ preparation durations, and $T_{\\text{1}}$ recovery gaps are jointly optimized using a self-supervised multilayer perceptron (MLP). The MLP is trained to minimize a Cramér-Rao bound-based loss function subject to explicit total scan time constraints. Integrated with subspace reconstruction, the optimized Omni-QALAS reduces the required number of readouts from six to five compared to MWF-QALAS. This optimization shortens the overall scan time by 16% while yielding higher $T_{\\text{1}}$ and $T_{\\text{2}}$ accuracy alongside improved MWF maps. Simulation, phantom, and in vivo validations demonstrate that the Omni-QALAS protocol provides accurate whole-brain multiparametric quantification at 1 mm isotropic resolution within 5 minutes, with demonstrated feasibility for faster acquisition down to 3 minutes 30 seconds.</p>","PeriodicalId":13245,"journal":{"name":"IEEE Transactions on Biomedical Engineering","volume":"PP ","pages":""},"PeriodicalIF":4.4000,"publicationDate":"2026-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1109/TBME.2026.3731202","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

3D-QALAS enables efficient multi-parametric $T_{\text{1}}$, $T_{\text{2}}$, and proton density (PD) mapping in a single scan; however, heuristic parameter selection limits image quality and myelin water fraction (MWF) quantification accuracy. While the subsequently proposed MWF-QALAS sequence improves MWF estimation, it requires an additional readout that prolongs scan time by approximately one minute and lacks precision for short $T_{\text{1}}$ and $T_{\text{2}}$ values. To address these limitations, we introduce Omni-QALAS (Optimized Myelin & Neurometric Imaging). The sequence flip angles, $T_{\text{2}}$ preparation durations, and $T_{\text{1}}$ recovery gaps are jointly optimized using a self-supervised multilayer perceptron (MLP). The MLP is trained to minimize a Cramér-Rao bound-based loss function subject to explicit total scan time constraints. Integrated with subspace reconstruction, the optimized Omni-QALAS reduces the required number of readouts from six to five compared to MWF-QALAS. This optimization shortens the overall scan time by 16% while yielding higher $T_{\text{1}}$ and $T_{\text{2}}$ accuracy alongside improved MWF maps. Simulation, phantom, and in vivo validations demonstrate that the Omni-QALAS protocol provides accurate whole-brain multiparametric quantification at 1 mm isotropic resolution within 5 minutes, with demonstrated feasibility for faster acquisition down to 3 minutes 30 seconds.

Omni-QALAS:优化的多参数成像,用于同时绘制$T_{1}$, $T_{2}$和髓磷脂水。
3D-QALAS可在单次扫描中实现高效的多参数$T_{\text{2}}$, $T_{\text{2}}$和质子密度(PD)映射;然而,启发式参数选择限制了图像质量和髓磷脂水分数(MWF)定量精度。虽然随后提出的MWF- qalas序列改善了MWF估计,但它需要额外的读出,使扫描时间延长了大约一分钟,并且对于短$T_{\text{2}}$和$T_{\text{2}}$值缺乏精度。为了解决这些限制,我们引入了Omni-QALAS(优化髓磷脂和神经测量成像)。利用自监督多层感知器(MLP)对序列翻转角度、$T_{\text{2}}$准备时间和$T_{\text{1}}$恢复间隙进行了联合优化。MLP被训练成最小化受显式总扫描时间约束的基于cram - rao界的损失函数。与MWF-QALAS相比,优化后的Omni-QALAS与子空间重建相结合,将所需的读出次数从6个减少到5个。此优化将总扫描时间缩短了16%,同时产生更高的$T_{\text{2}}$和$T_{\text{2}}$精度以及改进的MWF地图。仿真、模拟和体内验证表明,Omni-QALAS方案在5分钟内以1毫米各向同性分辨率提供准确的全脑多参数量化,并证明了将采集速度缩短至3分30秒的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Biomedical Engineering
IEEE Transactions on Biomedical Engineering 工程技术-工程:生物医学
CiteScore
9.40
自引率
4.30%
发文量
880
审稿时长
2.5 months
期刊介绍: IEEE Transactions on Biomedical Engineering contains basic and applied papers dealing with biomedical engineering. Papers range from engineering development in methods and techniques with biomedical applications to experimental and clinical investigations with engineering contributions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书