Dual-branch MRI denoising and motion artifact suppression with uncertainty estimation and segmentation-based evaluation

IF 3.2 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Medical physics Pub Date : 2026-09-07 DOI:10.1002/mp.70662
Mingfu Jiang, Chi Kin Lam, Zhuoneng Zhang, Poorya MohammadiNasab, Hing-Chiu Chang, Tong Tong, Hualong She, Zhen Yuan, Tao Tan
{"title":"Dual-branch MRI denoising and motion artifact suppression with uncertainty estimation and segmentation-based evaluation","authors":"Mingfu Jiang,&nbsp;Chi Kin Lam,&nbsp;Zhuoneng Zhang,&nbsp;Poorya MohammadiNasab,&nbsp;Hing-Chiu Chang,&nbsp;Tong Tong,&nbsp;Hualong She,&nbsp;Zhen Yuan,&nbsp;Tao Tan","doi":"10.1002/mp.70662","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Magnetic resonance (MR) images are essential for clinical diagnosis, yet their quality is often compromised by noise and motion artifacts, potentially obscuring anatomical details and reducing diagnostic accuracy. Existing deep learning approaches frequently address denoising and motion artifact suppression as separate tasks, overlook pixel correlations and varying noise levels, require manual parameter tuning, and lack uncertainty evaluation, thus limiting their practical utility in clinical settings.</p>\n </section>\n \n <section>\n \n <h3> Purpose</h3>\n \n <p>This study aims to develop a Dual-branch MRI Denoising and Motion Artifact Suppression with Uncertainty Estimation and Segmentation-based Evaluation (DbUSNet). The model is designed to adaptively handle varying noise and motion artifact levels, preserve complex structural details, and provide uncertainty estimates for the processed outputs. This may offer insights into downstream clinical tasks such as image segmentation.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>The DbUSNet integrates two specialized branches: A Heterogeneous Window Transformer Network (HWTNet) for adaptive denoising using both local and global feature modeling, and an improved U-Net based Motion Artifact Suppression Network (ASNet). Each branch is coupled with an estimation subnetwork—Noise Estimation Subnetwork (NES) and Artifact Estimation Subnetwork (AES)—to dynamically assess and adapt to input specific degradation levels. The outputs of both branches are fused via an attention-based fusion module. Uncertainty is quantified during inference using Monte Carlo (MC) dropout. The model was trained and tested on brain MR scans from Brats2021 dataset (2000 samples), OpenNeuro dataset (22 samples), and MR-ART dataset (148 samples), incorporating synthetic Rician noise and motion artifacts. Downstream segmentation performance was evaluated on the Medical Segmentation Decathlon (MSD) brain dataset (1666 samples) and a prostate MR dataset (203 samples).</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>On the Brats2021, OpenNeuro, and MR-ART testsets, DbUSNet achieved PSNR of 28.23 dB, 27.13 dB, and 27.83 dB, SSIM of 0.93, 0.91, and 0.92, NMSE of 0.08, 0.08, and 0.08, respectively. For the downstream segmentation task, the denoised and motion artifact suppressed outputs led to average Dice score improvements of 3.10%, 3.59%, 2.46%, and 2.15% for T1, T1ce, FLAIR, and T2 modalities in the MSD brain dataset, and 2.16% and 2.24% for T2 and ADC sequences in the prostate dataset.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>The DbUSNet framework jointly performs adaptive denoising and motion artifact suppression within a unified pipeline and enables pixel-wise uncertainty quantification. Evaluations on controlled brain MRI datasets show consistent image quality gains and improved downstream segmentation performance, though the limited size and healthy-only composition of real motion test cohorts restrict wide clinical extrapolation. This work delivers a feasible technical prototype for MR image enhancement; larger, diverse clinical patient datasets will be required to further validate its clinical utility.</p>\n </section>\n </div>","PeriodicalId":18384,"journal":{"name":"Medical physics","volume":"53 9","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2026-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical physics","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/mp.70662","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Magnetic resonance (MR) images are essential for clinical diagnosis, yet their quality is often compromised by noise and motion artifacts, potentially obscuring anatomical details and reducing diagnostic accuracy. Existing deep learning approaches frequently address denoising and motion artifact suppression as separate tasks, overlook pixel correlations and varying noise levels, require manual parameter tuning, and lack uncertainty evaluation, thus limiting their practical utility in clinical settings.

Purpose

This study aims to develop a Dual-branch MRI Denoising and Motion Artifact Suppression with Uncertainty Estimation and Segmentation-based Evaluation (DbUSNet). The model is designed to adaptively handle varying noise and motion artifact levels, preserve complex structural details, and provide uncertainty estimates for the processed outputs. This may offer insights into downstream clinical tasks such as image segmentation.

Methods

The DbUSNet integrates two specialized branches: A Heterogeneous Window Transformer Network (HWTNet) for adaptive denoising using both local and global feature modeling, and an improved U-Net based Motion Artifact Suppression Network (ASNet). Each branch is coupled with an estimation subnetwork—Noise Estimation Subnetwork (NES) and Artifact Estimation Subnetwork (AES)—to dynamically assess and adapt to input specific degradation levels. The outputs of both branches are fused via an attention-based fusion module. Uncertainty is quantified during inference using Monte Carlo (MC) dropout. The model was trained and tested on brain MR scans from Brats2021 dataset (2000 samples), OpenNeuro dataset (22 samples), and MR-ART dataset (148 samples), incorporating synthetic Rician noise and motion artifacts. Downstream segmentation performance was evaluated on the Medical Segmentation Decathlon (MSD) brain dataset (1666 samples) and a prostate MR dataset (203 samples).

Results

On the Brats2021, OpenNeuro, and MR-ART testsets, DbUSNet achieved PSNR of 28.23 dB, 27.13 dB, and 27.83 dB, SSIM of 0.93, 0.91, and 0.92, NMSE of 0.08, 0.08, and 0.08, respectively. For the downstream segmentation task, the denoised and motion artifact suppressed outputs led to average Dice score improvements of 3.10%, 3.59%, 2.46%, and 2.15% for T1, T1ce, FLAIR, and T2 modalities in the MSD brain dataset, and 2.16% and 2.24% for T2 and ADC sequences in the prostate dataset.

Conclusion

The DbUSNet framework jointly performs adaptive denoising and motion artifact suppression within a unified pipeline and enables pixel-wise uncertainty quantification. Evaluations on controlled brain MRI datasets show consistent image quality gains and improved downstream segmentation performance, though the limited size and healthy-only composition of real motion test cohorts restrict wide clinical extrapolation. This work delivers a feasible technical prototype for MR image enhancement; larger, diverse clinical patient datasets will be required to further validate its clinical utility.

基于不确定性估计和分割评估的双分支MRI去噪和运动伪影抑制。
背景:磁共振(MR)图像对临床诊断至关重要,但其质量经常受到噪声和运动伪影的影响,可能模糊解剖细节并降低诊断准确性。现有的深度学习方法经常将去噪和运动伪影抑制作为单独的任务,忽略了像素相关性和不同的噪声水平,需要手动调整参数,缺乏不确定性评估,从而限制了它们在临床环境中的实际应用。目的:研究基于不确定性估计和基于分割的评估(DbUSNet)的双分支MRI去噪和运动伪影抑制方法。该模型旨在自适应处理不同的噪声和运动伪影水平,保留复杂的结构细节,并为处理后的输出提供不确定性估计。这可能为下游临床任务(如图像分割)提供见解。方法:DbUSNet集成了两个专门的分支:异构窗口变压器网络(HWTNet),用于使用局部和全局特征建模进行自适应去噪,以及改进的基于U-Net的运动伪影抑制网络(ASNet)。每个分支都与一个估计子网(噪声估计子网(NES)和伪影估计子网(AES))相耦合,以动态评估和适应输入特定的退化水平。两个分支的输出通过基于注意力的融合模块进行融合。利用蒙特卡罗(MC) dropout对推理过程中的不确定性进行了量化。该模型在Brats2021数据集(2000个样本)、OpenNeuro数据集(22个样本)和MR- art数据集(148个样本)的脑磁共振扫描上进行了训练和测试,并纳入了合成噪声和运动伪影。在医学分割十项运动(MSD)大脑数据集(1666个样本)和前列腺磁共振数据集(203个样本)上评估下游分割性能。结果:在Brats2021、OpenNeuro和MR-ART测试集上,DbUSNet的PSNR分别为28.23 dB、27.13 dB和27.83 dB, SSIM分别为0.93、0.91和0.92,NMSE分别为0.08、0.08和0.08。对于下游分割任务,去噪和运动伪影抑制输出导致MSD大脑数据集中T1, T1ce, FLAIR和T2模式的平均Dice分数提高了3.10%,3.59%,2.46%和2.15%,前列腺数据集中T2和ADC序列的平均Dice分数提高了2.16%和2.24%。结论:DbUSNet框架在统一的管道中联合执行自适应去噪和运动伪影抑制,并实现逐像素的不确定性量化。对受控脑MRI数据集的评估显示出一致的图像质量提高和改进的下游分割性能,尽管真实运动测试队列的有限大小和仅健康组成限制了广泛的临床外推。本工作为磁共振图像增强提供了一个可行的技术原型;需要更大、更多样化的临床患者数据集来进一步验证其临床效用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical physics
Medical physics 医学-核医学
CiteScore
6.80
自引率
15.80%
发文量
660
审稿时长
1.7 months
期刊介绍: Medical Physics publishes original, high impact physics, imaging science, and engineering research that advances patient diagnosis and therapy through contributions in 1) Basic science developments with high potential for clinical translation 2) Clinical applications of cutting edge engineering and physics innovations 3) Broadly applicable and innovative clinical physics developments Medical Physics is a journal of global scope and reach. By publishing in Medical Physics your research will reach an international, multidisciplinary audience including practicing medical physicists as well as physics- and engineering based translational scientists. We work closely with authors of promising articles to improve their quality.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书