Minji Sun, Jae Hoon Lee, So Hee Kim, Jihoon Shin, Jaeyoung Kim
{"title":"Effect of tray relief amount and impression material type on dimensional accuracy of complete denture impressions.","authors":"Minji Sun, Jae Hoon Lee, So Hee Kim, Jihoon Shin, Jaeyoung Kim","doi":"10.1111/jopr.70230","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to evaluate the combined effects of tray relief amount and impression materials on the three-dimensional (3D) accuracy of complete denture impressions.</p><p><strong>Materials and methods: </strong>A fully edentulous maxillary cast and corresponding custom trays were digitally designed with a uniform 1.0 mm relief, and additional midpalatal relief of 0, 1.5, and 3 mm was incorporated. Impressions were made using four elastomeric impression materials and poured with Type IV dental stone. 3D surface deviation analysis was performed, and the average deviation and maximum absolute deviation (MAD) were calculated.</p><p><strong>Results: </strong>Across all impression materials, both the average deviation and the MAD increased as the midpalatal relief amount increased from 0 to 1.5 and 3 mm. Significant differences among the three relief conditions were confirmed for all materials (p < 0.05), and the post hoc test showed that every material exhibited a significant increase between the 0 and 3 mm conditions. Across all relief levels, no significant differences in average deviation were observed among the four materials. For MAD, a material-dependent difference was identified only at the 1.5 mm relief condition (p < 0.001).</p><p><strong>Conclusions: </strong>The results demonstrated that polymerization shrinkage of elastomeric impression materials can produce localized microrelief within relieved regions of edentulous impressions, resulting in polymerization-induced microrelief. Both the relief amount and the material type influenced the magnitude of shrinkage-related dimensional change, suggesting that the interaction between tray relief and material behavior affects impression accuracy in edentulous patients.</p>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":" ","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2026-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jopr.70230","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: The purpose of this study was to evaluate the combined effects of tray relief amount and impression materials on the three-dimensional (3D) accuracy of complete denture impressions.
Materials and methods: A fully edentulous maxillary cast and corresponding custom trays were digitally designed with a uniform 1.0 mm relief, and additional midpalatal relief of 0, 1.5, and 3 mm was incorporated. Impressions were made using four elastomeric impression materials and poured with Type IV dental stone. 3D surface deviation analysis was performed, and the average deviation and maximum absolute deviation (MAD) were calculated.
Results: Across all impression materials, both the average deviation and the MAD increased as the midpalatal relief amount increased from 0 to 1.5 and 3 mm. Significant differences among the three relief conditions were confirmed for all materials (p < 0.05), and the post hoc test showed that every material exhibited a significant increase between the 0 and 3 mm conditions. Across all relief levels, no significant differences in average deviation were observed among the four materials. For MAD, a material-dependent difference was identified only at the 1.5 mm relief condition (p < 0.001).
Conclusions: The results demonstrated that polymerization shrinkage of elastomeric impression materials can produce localized microrelief within relieved regions of edentulous impressions, resulting in polymerization-induced microrelief. Both the relief amount and the material type influenced the magnitude of shrinkage-related dimensional change, suggesting that the interaction between tray relief and material behavior affects impression accuracy in edentulous patients.
期刊介绍:
The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.