Ryuichiro Kakizaki, Junya Hagiwara, Yuki Hasegawa, Tsend-Ayush Batsaikhan, Chris B Agala, Linda E Sousse, Jeffrey D DellaVolpe, Perenlei Enkhbaatar
{"title":"Impact of Pulsatile Flow on Pulmonary Transvascular Fluid Flux During Veno-Pulmonary Arterial ECMO: A Pilot Ovine Study.","authors":"Ryuichiro Kakizaki, Junya Hagiwara, Yuki Hasegawa, Tsend-Ayush Batsaikhan, Chris B Agala, Linda E Sousse, Jeffrey D DellaVolpe, Perenlei Enkhbaatar","doi":"10.1097/SHK.0000000000002938","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Although flow pulsatility has been suggested to confer physiological benefits in other forms of mechanical circulatory support, its role in veno-pulmonary arterial extracorporeal membrane oxygenation (VP ECMO) has not yet been investigated. We hypothesized that non-pulsatile flow into the pulmonary circulation during VP ECMO may promote pulmonary transvascular fluid flux, whereas pulsatile flow may attenuate these effects.</p><p><strong>Methods: </strong>Six adult female sheep (41-53 kg) underwent VP ECMO and were randomly assigned to either non-pulsatile (n = 3) or pulsatile flow (n = 3) using an electrocardiogram (ECG)-synchronized cardiac system (SCS / iCOR, Xenios, Fresenius Medical Care, Germany) for 96 hours. The pulsatility was synchronized to heart rate by ECG. Lung lymph flow, pulmonary hemodynamics, extravascular lung water (EVLW), and histological findings were evaluated.</p><p><strong>Results: </strong>ECMO blood flow was maintained at 2.0 L/min in both groups. Lung lymph flow increased progressively over time in the non-pulsatile flow group, reaching approximately 3- to 4-fold of baseline; no such increase was observed in the pulsatile group. Mixed-effects analysis demonstrated significantly higher lung lymph flow and mean pulmonary arterial pressure in the non-pulsatile group. EVLW and histological interstitial edema tended to be higher in the non-pulsatile group.</p><p><strong>Conclusions: </strong>Non-pulsatile flow was associated with increased lung lymph flow and higher mean pulmonary arterial pressure in our pilot ovine study, whereas ECG-synchronized pulsatile flow appears to attenuate these changes. Further studies are warranted to investigate the role of pulsatile pulmonary arterial flow as a strategy to preserve pulmonary vascular fluid balance.</p>","PeriodicalId":21667,"journal":{"name":"SHOCK","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2026-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SHOCK","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/SHK.0000000000002938","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Although flow pulsatility has been suggested to confer physiological benefits in other forms of mechanical circulatory support, its role in veno-pulmonary arterial extracorporeal membrane oxygenation (VP ECMO) has not yet been investigated. We hypothesized that non-pulsatile flow into the pulmonary circulation during VP ECMO may promote pulmonary transvascular fluid flux, whereas pulsatile flow may attenuate these effects.
Methods: Six adult female sheep (41-53 kg) underwent VP ECMO and were randomly assigned to either non-pulsatile (n = 3) or pulsatile flow (n = 3) using an electrocardiogram (ECG)-synchronized cardiac system (SCS / iCOR, Xenios, Fresenius Medical Care, Germany) for 96 hours. The pulsatility was synchronized to heart rate by ECG. Lung lymph flow, pulmonary hemodynamics, extravascular lung water (EVLW), and histological findings were evaluated.
Results: ECMO blood flow was maintained at 2.0 L/min in both groups. Lung lymph flow increased progressively over time in the non-pulsatile flow group, reaching approximately 3- to 4-fold of baseline; no such increase was observed in the pulsatile group. Mixed-effects analysis demonstrated significantly higher lung lymph flow and mean pulmonary arterial pressure in the non-pulsatile group. EVLW and histological interstitial edema tended to be higher in the non-pulsatile group.
Conclusions: Non-pulsatile flow was associated with increased lung lymph flow and higher mean pulmonary arterial pressure in our pilot ovine study, whereas ECG-synchronized pulsatile flow appears to attenuate these changes. Further studies are warranted to investigate the role of pulsatile pulmonary arterial flow as a strategy to preserve pulmonary vascular fluid balance.
期刊介绍:
SHOCK®: Injury, Inflammation, and Sepsis: Laboratory and Clinical Approaches includes studies of novel therapeutic approaches, such as immunomodulation, gene therapy, nutrition, and others. The mission of the Journal is to foster and promote multidisciplinary studies, both experimental and clinical in nature, that critically examine the etiology, mechanisms and novel therapeutics of shock-related pathophysiological conditions. Its purpose is to excel as a vehicle for timely publication in the areas of basic and clinical studies of shock, trauma, sepsis, inflammation, ischemia, and related pathobiological states, with particular emphasis on the biologic mechanisms that determine the response to such injury. Making such information available will ultimately facilitate improved care of the traumatized or septic individual.