Orbscan IIz multimodal corneal topography dataset of anterior axial power maps with structured clinical parameters for unsupervised and self-supervised representation learning

IF 1.9 Q3 MULTIDISCIPLINARY SCIENCES
Data in Brief Pub Date : 2026-08-01 Epub Date: 2026-08-10 DOI:10.1016/j.dib.2026.113138
Ali Mustafa Ali Alshaykha, Qabas A. Hameed, Mohammed Basim Omar
{"title":"Orbscan IIz multimodal corneal topography dataset of anterior axial power maps with structured clinical parameters for unsupervised and self-supervised representation learning","authors":"Ali Mustafa Ali Alshaykha,&nbsp;Qabas A. Hameed,&nbsp;Mohammed Basim Omar","doi":"10.1016/j.dib.2026.113138","DOIUrl":null,"url":null,"abstract":"<div><div>We present a multimodal corneal topography dataset comprising 3000 anterior axial power maps acquired from 3000 unique patients using the Orbscan IIz slit-scanning device (Bausch &amp; Lomb) at a single private ophthalmology clinic in Iraq. The examinations were performed during routine clinical practice between 2007 and 2025 using the same diagnostic device throughout the acquisition period. Each image is paired with 19 structured clinical parameter fields extracted from the original device output using an automated OCR-based pipeline. These parameters include simulated keratometry astigmatism (SimK_Astig), maximum and minimum corneal power (MaxK and MinK), zone-specific irregularity indices, mean power, astigmatic power, steep and flat axis orientations across 3 mm and 5 mm optical apertures, corneal pachymetry at the thinnest point with spatial coordinates, anterior chamber depth, white-to-white diameter, pupil diameter, and angle kappa with intercept coordinates. All images were fully anonymized, cropped to the central map region, resized to 1024 × 1024 pixels, and saved in lossless PNG format. Following a quality control pipeline assessing image integrity, metadata completeness, and anatomical plausibility, 2633 image–metadata pairs satisfied the predefined inclusion criteria and constitute the quality-controlled subset characterized in this article. The dataset is released without diagnostic labels by design, positioning it as a foundation for unsupervised, self-supervised, and semi-supervised representation learning in anterior segment analysis. The complete dataset is available on Mendeley Data (DOI: 10.17,632/78wt2nc387.3) under a CC BY-NC 4.0 license.</div></div>","PeriodicalId":10973,"journal":{"name":"Data in Brief","volume":"68 ","pages":"Article 113138"},"PeriodicalIF":1.9000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Data in Brief","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352340926006852","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/10 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

We present a multimodal corneal topography dataset comprising 3000 anterior axial power maps acquired from 3000 unique patients using the Orbscan IIz slit-scanning device (Bausch & Lomb) at a single private ophthalmology clinic in Iraq. The examinations were performed during routine clinical practice between 2007 and 2025 using the same diagnostic device throughout the acquisition period. Each image is paired with 19 structured clinical parameter fields extracted from the original device output using an automated OCR-based pipeline. These parameters include simulated keratometry astigmatism (SimK_Astig), maximum and minimum corneal power (MaxK and MinK), zone-specific irregularity indices, mean power, astigmatic power, steep and flat axis orientations across 3 mm and 5 mm optical apertures, corneal pachymetry at the thinnest point with spatial coordinates, anterior chamber depth, white-to-white diameter, pupil diameter, and angle kappa with intercept coordinates. All images were fully anonymized, cropped to the central map region, resized to 1024 × 1024 pixels, and saved in lossless PNG format. Following a quality control pipeline assessing image integrity, metadata completeness, and anatomical plausibility, 2633 image–metadata pairs satisfied the predefined inclusion criteria and constitute the quality-controlled subset characterized in this article. The dataset is released without diagnostic labels by design, positioning it as a foundation for unsupervised, self-supervised, and semi-supervised representation learning in anterior segment analysis. The complete dataset is available on Mendeley Data (DOI: 10.17,632/78wt2nc387.3) under a CC BY-NC 4.0 license.
用于无监督和自监督表征学习的具有结构化临床参数的前轴功率图的多模态角膜地形图数据集
我们提出了一个多模式角膜地形图数据集,其中包括3000个前轴功率图,这些图来自伊拉克一家私人眼科诊所的3000名独特患者,使用Orbscan IIz裂隙扫描设备(Bausch & Lomb)。这些检查是在2007年至2025年的常规临床实践中进行的,在整个获得期间使用相同的诊断设备。每张图像与19个结构化临床参数字段配对,这些参数字段是使用基于自动ocr的管道从原始设备输出中提取的。这些参数包括模拟角膜测量散光(SimK_Astig)、最大和最小角膜度数(MaxK和MinK)、区域特定不规则指数、平均度数、散光度数、3 mm和5 mm光阑上的陡轴和平轴方向、最薄点的角膜度数(空间坐标)、前房深度、白到白直径、瞳孔直径和角kappa(截距坐标)。所有图像都经过完全匿名化处理,裁剪到中央地图区域,调整大小为1024 × 1024像素,并以无损PNG格式保存。通过质量控制管道评估图像完整性、元数据完整性和解剖合理性,2633对图像-元数据对满足预定义的包含标准,构成本文描述的质量控制子集。该数据集在发布时没有设计诊断标签,将其定位为前段分析中无监督、自监督和半监督表示学习的基础。完整的数据集可在Mendeley Data (DOI: 10.17,632/78wt2nc387.3)上获得CC BY-NC 4.0许可。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Data in Brief
Data in Brief MULTIDISCIPLINARY SCIENCES-
CiteScore
3.10
自引率
0.00%
发文量
996
审稿时长
70 days
期刊介绍: Data in Brief provides a way for researchers to easily share and reuse each other''s datasets by publishing data articles that: -Thoroughly describe your data, facilitating reproducibility. -Make your data, which is often buried in supplementary material, easier to find. -Increase traffic towards associated research articles and data, leading to more citations. -Open up doors for new collaborations. Because you never know what data will be useful to someone else, Data in Brief welcomes submissions that describe data from all research areas.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书