Testing the null hypothesis of uncoupling between mean arterial pressure and mean cerebral blood velocity in health and pathology via different surrogate strategies.

IF 2.5 4区 医学 Q3 BIOPHYSICS
Alberto Porta, Beatrice Cairo, Ilaria Burzo, Beatrice De Maria, Martina Anguissola, Marco Ranucci, Vlasta Bari
{"title":"Testing the null hypothesis of uncoupling between mean arterial pressure and mean cerebral blood velocity in health and pathology via different surrogate strategies.","authors":"Alberto Porta, Beatrice Cairo, Ilaria Burzo, Beatrice De Maria, Martina Anguissola, Marco Ranucci, Vlasta Bari","doi":"10.1088/1361-6579/ae9f12","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective</i>. The dynamic cerebral autoregulation (dCA) limits variability of mean cerebral blood velocity (MCBv) despite mean arterial pressure (MAP) variations through a myriad of nonlinear mechanisms. However, dCA operates in association with the flow-to-pressure pathway. This study aims at characterizing the closed loop MCBv-MAP relationship by separating the dependence of MAP on MCBv from that over the reverse pathway using different surrogate approaches.<i>Approach.</i>Analyses were carried out in 26 healthy controls (HCs, age: 43 ± 11 yr, 13 males, 13 females) and 48 severe aortic valve stenosis patients undergoing surgical aortic valve replacement (SAVR, age: 62 ± 14 yr; 35 males, 13 females) before and after surgery. Active standing (STAND) from supine resting (REST) was exploited to challenge dCA. A state space correspondence method based on model-free cross-predictability was exploited to estimate the degree of MCBv dependence on MAP and vice versa and two different types of surrogates destroying nonlinear components or preserving them as much as possible were utilized.<i>Main results.</i>We found that: i) STAND deteriorates dCA in HCs; ii) in SAVR patients STAND does not affect dCA either before or after surgery, but a pre-surgery activation of flow-to-pressure link is present at REST; iii) in HCs preserving nonlinear dynamics when testing the significance of the pressure-to-flow link provides results different from those derived while maintaining exclusively linear dynamics.<i>Significance.</i>Results stressed the pathophysiological relevance of applying a nonlinear directional approach to disentangle closed loop MCBv-MAP relationship and suggest that conclusions might depend on the strategy adopted to generate surrogates.</p>","PeriodicalId":20047,"journal":{"name":"Physiological measurement","volume":" ","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2026-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiological measurement","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6579/ae9f12","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective. The dynamic cerebral autoregulation (dCA) limits variability of mean cerebral blood velocity (MCBv) despite mean arterial pressure (MAP) variations through a myriad of nonlinear mechanisms. However, dCA operates in association with the flow-to-pressure pathway. This study aims at characterizing the closed loop MCBv-MAP relationship by separating the dependence of MAP on MCBv from that over the reverse pathway using different surrogate approaches.Approach.Analyses were carried out in 26 healthy controls (HCs, age: 43 ± 11 yr, 13 males, 13 females) and 48 severe aortic valve stenosis patients undergoing surgical aortic valve replacement (SAVR, age: 62 ± 14 yr; 35 males, 13 females) before and after surgery. Active standing (STAND) from supine resting (REST) was exploited to challenge dCA. A state space correspondence method based on model-free cross-predictability was exploited to estimate the degree of MCBv dependence on MAP and vice versa and two different types of surrogates destroying nonlinear components or preserving them as much as possible were utilized.Main results.We found that: i) STAND deteriorates dCA in HCs; ii) in SAVR patients STAND does not affect dCA either before or after surgery, but a pre-surgery activation of flow-to-pressure link is present at REST; iii) in HCs preserving nonlinear dynamics when testing the significance of the pressure-to-flow link provides results different from those derived while maintaining exclusively linear dynamics.Significance.Results stressed the pathophysiological relevance of applying a nonlinear directional approach to disentangle closed loop MCBv-MAP relationship and suggest that conclusions might depend on the strategy adopted to generate surrogates.

通过不同的替代策略检验健康和病理中平均动脉压和平均脑血流速度不耦合的原假设。
目的:动态脑自动调节(dCA)通过无数非线性机制限制平均动脉压(MAP)变化的平均脑血流速度(MCBv)的变异性。然而,dCA与流量-压力通路相关。本研究旨在通过使用不同的替代方法将MAP对MCBv的依赖与反向途径上的依赖分离开来,从而表征MCBv-MAP的闭环关系。方法:对26例健康对照(hc,年龄43±11岁,男13例,女13例)和48例重度主动脉瓣狭窄患者(SAVR,年龄62±14岁,男35例,女13例)术前、术后进行分析。利用仰卧休息(REST)的主动站立(STAND)来挑战dCA。利用一种基于无模型交叉可预测性的状态空间对应方法来估计MCBv对MAP的依赖程度,以及MAP对MCBv的依赖程度,并利用两种不同类型的代理来尽可能地破坏或保留非线性分量。主要结果:我们发现:i) STAND使hcc中的dCA恶化;ii)在SAVR患者中,STAND在术前或术后均不影响dCA,但在REST时存在术前血流-压力链接激活;iii)在hc中,当测试压力-流量联系的重要性时,保持非线性动力学的结果与完全保持线性动力学的结果不同。意义:结果强调了应用非线性定向方法解开闭合环路MCBv-MAP关系的病理生理学相关性,并表明结论可能取决于所采用的生成替代物的策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Physiological measurement
Physiological measurement 生物-工程:生物医学
CiteScore
5.50
自引率
9.40%
发文量
124
审稿时长
3 months
期刊介绍: Physiological Measurement publishes papers about the quantitative assessment and visualization of physiological function in clinical research and practice, with an emphasis on the development of new methods of measurement and their validation. Papers are published on topics including: applied physiology in illness and health electrical bioimpedance, optical and acoustic measurement techniques advanced methods of time series and other data analysis biomedical and clinical engineering in-patient and ambulatory monitoring point-of-care technologies novel clinical measurements of cardiovascular, neurological, and musculoskeletal systems. measurements in molecular, cellular and organ physiology and electrophysiology physiological modeling and simulation novel biomedical sensors, instruments, devices and systems measurement standards and guidelines.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书