Multi-fidelity Monte Carlo fusion for BNCT dose calculation using a dual-branch network

IF 3.2 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Medical physics Pub Date : 2026-08-24 DOI:10.1002/mp.70646
Leiming Li, Xin Hong, Yongquan Wang, Gan Huang, Zhiqiang Wu, Yingjie Xiao, Hiroki Tanaka, Hiroshi Watabe
{"title":"Multi-fidelity Monte Carlo fusion for BNCT dose calculation using a dual-branch network","authors":"Leiming Li,&nbsp;Xin Hong,&nbsp;Yongquan Wang,&nbsp;Gan Huang,&nbsp;Zhiqiang Wu,&nbsp;Yingjie Xiao,&nbsp;Hiroki Tanaka,&nbsp;Hiroshi Watabe","doi":"10.1002/mp.70646","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Boron neutron capture therapy (BNCT) is a binary radiotherapy that selectively kills tumor cells. Its clinical implementation relies on Monte Carlo (MC)-based treatment planning systems, which are time-consuming and limit clinical workflow efficiency.</p>\n </section>\n \n <section>\n \n <h3> Purpose</h3>\n \n <p>To address this limitation, we propose a Multi-Fidelity MC-based Dual-Branch Network (MFMC-DBN) that leverages complementary information from low- and high-fidelity MC simulations through dual-branch feature fusion, enabling accurate and efficient BNCT dose calculation.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>The model was trained, validated, and tested using clinical data from 112 glioblastoma patients. Low-statistics coarse and fine mesh MC dose distributions (6.5×10<sup>6</sup> particle histories) and patient CT information were used to predict three-dimensional dose distributions. Performance was compared with an MC denoising method and a conventional neural network (NN) approach.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>MFMC-DBN outperformed both the NN and MC denoising methods across evaluated metrics. It achieved a mean absolute percentage error (MAPE) of 1.98% in the gross tumor volume (GTV). Organ-specific MAPEs ranged from 1.1% to 3.9%, with a maximum mean absolute error (MAE) of0.28 Gy (RBE). Gamma analysis further showed high spatial agreement, with passing rates of 99.8% within the patient contour and 99.3% in the GTV under the 3%/3 mm criterion. The proposed method maintained high dosimetric accuracy while substantially accelerating BNCT dose calculation.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>MFMC-DBN effectively integrates multi-fidelity MC information through a dual-branch attention mechanism, enabling rapid and accurate 3D BNCT dose prediction. By significantly reducing computation time compared with full MC simulations while preserving dosimetric fidelity, these results support the feasibility of the proposed framework for accelerated BNCT dose calculation under a fixed beam configuration.</p>\n </section>\n </div>","PeriodicalId":18384,"journal":{"name":"Medical physics","volume":"53 9","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2026-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13501215/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical physics","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/mp.70646","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Boron neutron capture therapy (BNCT) is a binary radiotherapy that selectively kills tumor cells. Its clinical implementation relies on Monte Carlo (MC)-based treatment planning systems, which are time-consuming and limit clinical workflow efficiency.

Purpose

To address this limitation, we propose a Multi-Fidelity MC-based Dual-Branch Network (MFMC-DBN) that leverages complementary information from low- and high-fidelity MC simulations through dual-branch feature fusion, enabling accurate and efficient BNCT dose calculation.

Methods

The model was trained, validated, and tested using clinical data from 112 glioblastoma patients. Low-statistics coarse and fine mesh MC dose distributions (6.5×106 particle histories) and patient CT information were used to predict three-dimensional dose distributions. Performance was compared with an MC denoising method and a conventional neural network (NN) approach.

Results

MFMC-DBN outperformed both the NN and MC denoising methods across evaluated metrics. It achieved a mean absolute percentage error (MAPE) of 1.98% in the gross tumor volume (GTV). Organ-specific MAPEs ranged from 1.1% to 3.9%, with a maximum mean absolute error (MAE) of0.28 Gy (RBE). Gamma analysis further showed high spatial agreement, with passing rates of 99.8% within the patient contour and 99.3% in the GTV under the 3%/3 mm criterion. The proposed method maintained high dosimetric accuracy while substantially accelerating BNCT dose calculation.

Conclusions

MFMC-DBN effectively integrates multi-fidelity MC information through a dual-branch attention mechanism, enabling rapid and accurate 3D BNCT dose prediction. By significantly reducing computation time compared with full MC simulations while preserving dosimetric fidelity, these results support the feasibility of the proposed framework for accelerated BNCT dose calculation under a fixed beam configuration.

基于双支路网络的多保真蒙特卡罗融合BNCT剂量计算。
背景:硼中子俘获疗法(BNCT)是一种选择性杀伤肿瘤细胞的二元放疗。它的临床实施依赖于基于蒙特卡罗(MC)的治疗计划系统,这是耗时的,限制了临床工作流程的效率。为了解决这一限制,我们提出了一种基于多保真MC的双支路网络(MFMC-DBN),通过双支路特征融合利用低保真MC和高保真MC模拟的互补信息,实现准确高效的BNCT剂量计算。方法:利用112例胶质母细胞瘤患者的临床数据对模型进行训练、验证和测试。低统计量粗、细网格MC剂量分布(6.5×106粒子史)和患者CT信息用于预测三维剂量分布。比较了MC去噪方法和传统神经网络(NN)去噪方法的性能。结果:MFMC-DBN在评估指标上优于NN和MC去噪方法。它在总肿瘤体积(GTV)上的平均绝对百分比误差(MAPE)为1.98%。器官特异性mape范围为1.1% ~ 3.9%,最大平均绝对误差(MAE)为0.28 Gy (RBE)。Gamma分析进一步显示了高度的空间一致性,在3%/ 3mm标准下,患者轮廓内的通过率为99.8%,GTV内的通过率为99.3%。该方法保持了较高的剂量学准确度,同时大大加快了BNCT剂量计算速度。结论:MFMC-DBN通过双分支注意机制有效整合多保真MC信息,实现了快速准确的3D BNCT剂量预测。与全MC模拟相比,计算时间大大减少,同时保持剂量学保真度,这些结果支持了在固定光束配置下加速BNCT剂量计算框架的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical physics
Medical physics 医学-核医学
CiteScore
6.80
自引率
15.80%
发文量
660
审稿时长
1.7 months
期刊介绍: Medical Physics publishes original, high impact physics, imaging science, and engineering research that advances patient diagnosis and therapy through contributions in 1) Basic science developments with high potential for clinical translation 2) Clinical applications of cutting edge engineering and physics innovations 3) Broadly applicable and innovative clinical physics developments Medical Physics is a journal of global scope and reach. By publishing in Medical Physics your research will reach an international, multidisciplinary audience including practicing medical physicists as well as physics- and engineering based translational scientists. We work closely with authors of promising articles to improve their quality.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书