Osama A Smettei, Sawsan A Sayed, Fatin M Ahmed, Tawfeeq H Alharbi, Mohammed Saied, Rami M Abazid
{"title":"Value of the Non-enhanced Cardiac Computed Tomography Scan Analysis in Determination of the Appropriate Coronary CT Angiography Scan Protocol.","authors":"Osama A Smettei, Sawsan A Sayed, Fatin M Ahmed, Tawfeeq H Alharbi, Mohammed Saied, Rami M Abazid","doi":"10.37616/2212-5043.1496","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Coronary computed tomography angiography (CCTA) is a cornerstone in the assessment of coronary artery disease. Despite technological advancements, balancing radiation does with diagnostic image quality remains a challenge. This study evaluates whether assessing preliminary non-enhanced CT scans allows for the optimization of CCTA gating protocols to enhance image quality and minimize radiation exposure.</p><p><strong>Methods: </strong>We prospectively analyzed 150 patients undergoing CCTA on a 256-slice scanner. Non-enhanced scans were used to identify motion artifacts or anatomical challenges. Based on these findings, a specific gating protocol (prospective, prospective with padding, or retrospective) was selected. This cohort was compared to a control group of 150 standard CCTAs performed without protocol pre-selection. Image quality was assessed on a four-point scale, and radiation doses were recorded.</p><p><strong>Results: </strong>The mean patient age was 49 years, with a mean heart rate (HR) of 62 ± 14 beats per minute (bpm). Subjective image quality was significantly higher in the pre-selection group, particularly for patients with HR > 65 bpm (3.5 ± 0.5 vs. 2.8 ± 0.8; p = 0.06). The mean radiation dose was significantly lower in the pre-selection group (4.9 ± 1.4 vs. 7.5 ± 1.8 mSv; p < 0.01). Furthermore, the requirement for high-radiation protocols (padding or retrospective gating) was reduced by 50% in the pre-selection group (14/150 vs. 28/150 scans).</p><p><strong>Conclusion: </strong>Utilizing non-enhanced CT scans to tailor 256-slice CCTA protocols significantly improves image quality and reduces radiation exposure. This strategy offers a more personalized approach to cardiac imaging and should be considered for routine clinical practice.</p>","PeriodicalId":17319,"journal":{"name":"Journal of the Saudi Heart Association","volume":"38 2","pages":"4"},"PeriodicalIF":1.4000,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13489147/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Saudi Heart Association","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37616/2212-5043.1496","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: Coronary computed tomography angiography (CCTA) is a cornerstone in the assessment of coronary artery disease. Despite technological advancements, balancing radiation does with diagnostic image quality remains a challenge. This study evaluates whether assessing preliminary non-enhanced CT scans allows for the optimization of CCTA gating protocols to enhance image quality and minimize radiation exposure.
Methods: We prospectively analyzed 150 patients undergoing CCTA on a 256-slice scanner. Non-enhanced scans were used to identify motion artifacts or anatomical challenges. Based on these findings, a specific gating protocol (prospective, prospective with padding, or retrospective) was selected. This cohort was compared to a control group of 150 standard CCTAs performed without protocol pre-selection. Image quality was assessed on a four-point scale, and radiation doses were recorded.
Results: The mean patient age was 49 years, with a mean heart rate (HR) of 62 ± 14 beats per minute (bpm). Subjective image quality was significantly higher in the pre-selection group, particularly for patients with HR > 65 bpm (3.5 ± 0.5 vs. 2.8 ± 0.8; p = 0.06). The mean radiation dose was significantly lower in the pre-selection group (4.9 ± 1.4 vs. 7.5 ± 1.8 mSv; p < 0.01). Furthermore, the requirement for high-radiation protocols (padding or retrospective gating) was reduced by 50% in the pre-selection group (14/150 vs. 28/150 scans).
Conclusion: Utilizing non-enhanced CT scans to tailor 256-slice CCTA protocols significantly improves image quality and reduces radiation exposure. This strategy offers a more personalized approach to cardiac imaging and should be considered for routine clinical practice.
目的:冠状动脉ct血管造影(CCTA)是评估冠状动脉疾病的基础。尽管技术进步,平衡辐射与诊断图像质量仍然是一个挑战。本研究评估评估初步非增强CT扫描是否允许优化CCTA门控方案,以提高图像质量并减少辐射暴露。方法:我们前瞻性地分析了150例在256层扫描仪上接受CCTA的患者。非增强扫描用于识别运动伪影或解剖挑战。基于这些发现,选择了一种特定的门控方案(前瞻性、前瞻性加填充或回顾性)。该队列与对照组的150个标准ccta进行比较,没有方案预选。以四分制评估图像质量,并记录辐射剂量。结果:患者平均年龄49岁,平均心率(HR) 62±14次/分(bpm)。预选组的主观图像质量明显更高,尤其是心率> 65 bpm的患者(3.5±0.5 vs. 2.8±0.8;p = 0.06)。预选择组的平均辐射剂量显著低于预选择组(4.9±1.4 vs. 7.5±1.8 mSv; p < 0.01)。此外,预选组对高辐射方案(填充或回顾性门控)的要求减少了50%(14/150比28/150扫描)。结论:利用非增强CT扫描定制256层CCTA方案可显著提高图像质量并减少辐射暴露。这种策略为心脏成像提供了一种更加个性化的方法,应该在常规临床实践中加以考虑。