Near-infrared spectroscopy for estimating mixed venous oxygen saturation and cardiac output during off-pump coronary artery bypass grafting: a prospective observational study.

IF 2.6 3区 医学 Q2 ANESTHESIOLOGY
Chahyun Oh, Soomin Lee, Sujin Baek, Hyeyoung Choi, Man-Shik Shim, Sang-Jun Park, Yunseo Ku, Boohwi Hong, Yoon-Hee Kim
{"title":"Near-infrared spectroscopy for estimating mixed venous oxygen saturation and cardiac output during off-pump coronary artery bypass grafting: a prospective observational study.","authors":"Chahyun Oh, Soomin Lee, Sujin Baek, Hyeyoung Choi, Man-Shik Shim, Sang-Jun Park, Yunseo Ku, Boohwi Hong, Yoon-Hee Kim","doi":"10.1007/s10877-026-01477-1","DOIUrl":null,"url":null,"abstract":"<p><p>To evaluate whether jugular venous NIRS (rSjvO₂) and baseline-calibrated cerebral NIRS (cal-rScO₂) can serve as surrogates for mixed venous oxygen saturation (SvO₂), and whether these inputs can support continuous cardiac output (CO) estimation during off-pump coronary artery bypass grafting (OPCAB). In this prospective observational study, 25 adults undergoing elective OPCAB were enrolled at a single tertiary center. NIRS sensors were placed over the left internal jugular vein (IJV) under ultrasound guidance and over the bilateral forehead. Pulmonary artery catheter measurements served as the reference for SvO₂ and thermodilution CO (CO<sub>TD</sub>). Agreement was assessed using Bland-Altman analysis with linear mixed-effects modeling, and trending ability by error grid analysis. CO was estimated using a previously derived modified Fick equation. rSjvO₂ showed modest bias versus SvO₂ (2.0%) but wide limits of agreement (LoA, - 14.9 to 18.9%). Accuracy varied with jugular anatomy, with the lowest error at an IJV depth of 1.38 cm. Cal-rScO₂ showed better agreement (bias 0.8%; LoA, - 7.8 to 9.4%), excellent discrimination for SvO₂ <65% (AUC, 0.970), and good trending ability. In contrast, NIRS-based CO estimation showed significant proportional bias, 33.0% percentage error (95% CI, 27.4 to 41.5%), and poor trending ability. Cal-rScO₂ appears to be a useful surrogate for SvO₂ trending during OPCAB after simple one-point calibration. Jugular NIRS may be useful in selected patients, whereas NIRS-based CO estimation remained clinically insufficient.Trial registration: Clinical Research Information Service (CRIS), Republic of Korea (KCT0007918 November 18, 2022).</p>","PeriodicalId":15513,"journal":{"name":"Journal of Clinical Monitoring and Computing","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2026-08-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Monitoring and Computing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10877-026-01477-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

To evaluate whether jugular venous NIRS (rSjvO₂) and baseline-calibrated cerebral NIRS (cal-rScO₂) can serve as surrogates for mixed venous oxygen saturation (SvO₂), and whether these inputs can support continuous cardiac output (CO) estimation during off-pump coronary artery bypass grafting (OPCAB). In this prospective observational study, 25 adults undergoing elective OPCAB were enrolled at a single tertiary center. NIRS sensors were placed over the left internal jugular vein (IJV) under ultrasound guidance and over the bilateral forehead. Pulmonary artery catheter measurements served as the reference for SvO₂ and thermodilution CO (COTD). Agreement was assessed using Bland-Altman analysis with linear mixed-effects modeling, and trending ability by error grid analysis. CO was estimated using a previously derived modified Fick equation. rSjvO₂ showed modest bias versus SvO₂ (2.0%) but wide limits of agreement (LoA, - 14.9 to 18.9%). Accuracy varied with jugular anatomy, with the lowest error at an IJV depth of 1.38 cm. Cal-rScO₂ showed better agreement (bias 0.8%; LoA, - 7.8 to 9.4%), excellent discrimination for SvO₂ <65% (AUC, 0.970), and good trending ability. In contrast, NIRS-based CO estimation showed significant proportional bias, 33.0% percentage error (95% CI, 27.4 to 41.5%), and poor trending ability. Cal-rScO₂ appears to be a useful surrogate for SvO₂ trending during OPCAB after simple one-point calibration. Jugular NIRS may be useful in selected patients, whereas NIRS-based CO estimation remained clinically insufficient.Trial registration: Clinical Research Information Service (CRIS), Republic of Korea (KCT0007918 November 18, 2022).

近红外光谱估计非体外循环冠状动脉旁路移植术中混合静脉氧饱和度和心输出量:一项前瞻性观察研究。
评估颈静脉NIRS (rSjvO₂)和基线校准的脑NIRS (cal-rScO₂)是否可以作为混合静脉氧饱和度(SvO₂)的替代指标,以及这些输入是否可以支持非体外循环冠状动脉旁路移植术(OPCAB)期间持续心输出量(CO)的估计。在这项前瞻性观察研究中,25名接受选择性OPCAB的成年人被纳入一个三级中心。在超声引导下将近红外传感器置于左侧颈内静脉(IJV)和双侧前额。肺动脉导管测量作为SvO₂和热溶CO (COTD)的参考。使用Bland-Altman分析和线性混合效应模型评估一致性,并通过误差网格分析评估趋势能力。使用先前导出的修正的菲克方程估计CO。rSjvO₂与SvO₂的偏差较小(2.0%),但一致性范围很广(LoA, - 14.9至18.9%)。准确度随颈静脉解剖结构的不同而不同,在IJV深度1.38 cm时误差最小。Cal-rScO 2表现出更好的一致性(偏差为0.8%;LoA为- 7.8至9.4%),对SvO 2具有良好的辨别能力
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.30
自引率
13.60%
发文量
144
审稿时长
6-12 weeks
期刊介绍: The Journal of Clinical Monitoring and Computing is a clinical journal publishing papers related to technology in the fields of anaesthesia, intensive care medicine, emergency medicine, and peri-operative medicine. The journal has links with numerous specialist societies, including editorial board representatives from the European Society for Computing and Technology in Anaesthesia and Intensive Care (ESCTAIC), the Society for Technology in Anesthesia (STA), the Society for Complex Acute Illness (SCAI) and the NAVAt (NAVigating towards your Anaestheisa Targets) group. The journal publishes original papers, narrative and systematic reviews, technological notes, letters to the editor, editorial or commentary papers, and policy statements or guidelines from national or international societies. The journal encourages debate on published papers and technology, including letters commenting on previous publications or technological concerns. The journal occasionally publishes special issues with technological or clinical themes, or reports and abstracts from scientificmeetings. Special issues proposals should be sent to the Editor-in-Chief. Specific details of types of papers, and the clinical and technological content of papers considered within scope can be found in instructions for authors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书