Serial transthoracic echocardiography for hemodynamic monitoring and early warning of hypotension during elective cesarean delivery: a prospective observational study.
Weiping Liu, Yongde Zhou, Dan Li, Lijie Sun, Xuedong Wang, Ting Fan, Xiangyang Guo, Min Li, Chengmei Shi
{"title":"Serial transthoracic echocardiography for hemodynamic monitoring and early warning of hypotension during elective cesarean delivery: a prospective observational study.","authors":"Weiping Liu, Yongde Zhou, Dan Li, Lijie Sun, Xuedong Wang, Ting Fan, Xiangyang Guo, Min Li, Chengmei Shi","doi":"10.1007/s10877-026-01485-1","DOIUrl":null,"url":null,"abstract":"<p><p>Spinal anesthesia during cesarean delivery frequently causes maternal hypotension. Early detection of hemodynamic compromise before blood pressure decline could enable timely intervention. This study evaluates the use of serial transthoracic echocardiography (TTE) as a monitoring tool for early detection of hemodynamic fluctuation. To characterize the temporal sequence of hemodynamic changes using serial TTE, with emphasis on the relationship between stroke volume (SV) reduction and subsequent hypotension, and to assess the potential of TTE‑derived parameters as physiological indicators of preload changes. Prospective observational study. Single-center trial. Thirty healthy term pregnant women (ASA I‑II) undergoing elective cesarean delivery under spinal anesthesia. Serial TTE examinations were performed at 13 predefined time points. Left ventricular diameters (LVIDd, LVIDs) were measured and volumes (EDV, ESV) were derived using the Teichholz method, from which stroke volume, cardiac output, cardiac index, and ejection fraction were calculated. Temporal relationship between SV decline and hypotension onset. After spinal anesthesia, left ventricular end-diastolic volume (EDV) decreased by 34.6%, stroke volume (SV) by 36.2%, cardiac output (CO) by 38.7% (all P < 0.001). Hypotension (SBP drop > 20%) occurred in 76.7%. Crucially, SV reduction preceded blood pressure fall: at the first post‑spinal measurement, SV had already decreased by 30.6%, while systolic BP had fallen by only 12.2%. Left ventricular ejection fraction (LVEF) remained stable throughout. After fetal delivery, all parameters partially recovered. Serial TTE monitoring detects a significant reduction in SV consistently before hypotension becomes clinically apparent, demonstrating the potential of TTE‑derived parameters as physiological indicators of preload changes. These findings establish a monitoring‑based physiological baseline for future hypothesis‑testing in obstetric anesthesia.Trial registration: Chinese Clinical Trial Registry (ChiCTR2500111576; registered 3 November 2025).</p>","PeriodicalId":15513,"journal":{"name":"Journal of Clinical Monitoring and Computing","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2026-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Monitoring and Computing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10877-026-01485-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Spinal anesthesia during cesarean delivery frequently causes maternal hypotension. Early detection of hemodynamic compromise before blood pressure decline could enable timely intervention. This study evaluates the use of serial transthoracic echocardiography (TTE) as a monitoring tool for early detection of hemodynamic fluctuation. To characterize the temporal sequence of hemodynamic changes using serial TTE, with emphasis on the relationship between stroke volume (SV) reduction and subsequent hypotension, and to assess the potential of TTE‑derived parameters as physiological indicators of preload changes. Prospective observational study. Single-center trial. Thirty healthy term pregnant women (ASA I‑II) undergoing elective cesarean delivery under spinal anesthesia. Serial TTE examinations were performed at 13 predefined time points. Left ventricular diameters (LVIDd, LVIDs) were measured and volumes (EDV, ESV) were derived using the Teichholz method, from which stroke volume, cardiac output, cardiac index, and ejection fraction were calculated. Temporal relationship between SV decline and hypotension onset. After spinal anesthesia, left ventricular end-diastolic volume (EDV) decreased by 34.6%, stroke volume (SV) by 36.2%, cardiac output (CO) by 38.7% (all P < 0.001). Hypotension (SBP drop > 20%) occurred in 76.7%. Crucially, SV reduction preceded blood pressure fall: at the first post‑spinal measurement, SV had already decreased by 30.6%, while systolic BP had fallen by only 12.2%. Left ventricular ejection fraction (LVEF) remained stable throughout. After fetal delivery, all parameters partially recovered. Serial TTE monitoring detects a significant reduction in SV consistently before hypotension becomes clinically apparent, demonstrating the potential of TTE‑derived parameters as physiological indicators of preload changes. These findings establish a monitoring‑based physiological baseline for future hypothesis‑testing in obstetric anesthesia.Trial registration: Chinese Clinical Trial Registry (ChiCTR2500111576; registered 3 November 2025).
剖宫产时腰麻常引起低血压。在血压下降之前早期发现血流动力学损害可以及时干预。本研究评估了连续经胸超声心动图(TTE)作为早期检测血流动力学波动的监测工具的使用。利用连续TTE表征血流动力学变化的时间序列,重点研究卒中容量(SV)减少与随后的低血压之间的关系,并评估TTE衍生参数作为预负荷变化生理指标的潜力。前瞻性观察研究。单中心试验。30名健康足月孕妇(ASA I - II)在脊髓麻醉下择期剖宫产。在13个预定时间点进行连续TTE检查。采用Teichholz法测量左心室直径(LVIDd、LVIDs),计算左心室容积(EDV、ESV),计算卒中容积、心输出量、心脏指数和射血分数。SV下降与低血压发病的时间关系。脊髓麻醉后左室舒张末期容积(EDV)下降34.6%,卒中容积(SV)下降36.2%,心输出量(CO)下降38.7% (P均为20%)。至关重要的是,SV降低先于血压下降:在第一次脊柱后测量时,SV已经下降了30.6%,而收缩压仅下降了12.2%。左室射血分数(LVEF)始终保持稳定。分娩后,各项指标部分恢复。在低血压在临床上变得明显之前,连续TTE监测可以持续检测到SV的显著降低,这证明了TTE衍生参数作为负荷前变化的生理指标的潜力。这些发现为未来产科麻醉的假设检验建立了基于监测的生理基线。试验注册:中国临床试验注册中心(ChiCTR2500111576,于2025年11月3日注册)。
期刊介绍:
The Journal of Clinical Monitoring and Computing is a clinical journal publishing papers related to technology in the fields of anaesthesia, intensive care medicine, emergency medicine, and peri-operative medicine.
The journal has links with numerous specialist societies, including editorial board representatives from the European Society for Computing and Technology in Anaesthesia and Intensive Care (ESCTAIC), the Society for Technology in Anesthesia (STA), the Society for Complex Acute Illness (SCAI) and the NAVAt (NAVigating towards your Anaestheisa Targets) group.
The journal publishes original papers, narrative and systematic reviews, technological notes, letters to the editor, editorial or commentary papers, and policy statements or guidelines from national or international societies. The journal encourages debate on published papers and technology, including letters commenting on previous publications or technological concerns. The journal occasionally publishes special issues with technological or clinical themes, or reports and abstracts from scientificmeetings. Special issues proposals should be sent to the Editor-in-Chief. Specific details of types of papers, and the clinical and technological content of papers considered within scope can be found in instructions for authors.