{"title":"High spatial resolution dual-ended readout PET detector based on continuous resistive layer silicon photomultiplier.","authors":"Jiahao Xie, Haibo Wang, Junwei Du","doi":"10.1088/1361-6560/ae9a28","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>Continuous resistive layer position-sensitive silicon photomultiplier (CRL PS-SiPM) is a class of position-sensitive SiPMs developed for the readout of fine-pitch scintillator crystal arrays. This study aimed to evaluate the performance of dual-ended readout positron emission tomography (PET) detectors based on CRL PS-SiPMs and 0.5 mm pitch LYSO arrays.<i>Approach.</i>A dual-ended readout detector was constructed by coupling two CRL PS-SiPMs to both ends of a 10 × 10 array of polished LYSO elements, each measuring 0.44 × 0.44 × 20 mm<sup>3</sup>. Each CRL PS-SiPM had an active area of 6.24 × 6.24 mm<sup>2</sup>and was fabricated using 20<i>µ</i>m microcells. Detector performance, including flood histogram quality, energy resolution, and coincidence timing resolution (CTR), was characterized at bias voltages ranging from 30.0 to 33.0 V in 0.5 V increments, and at 3<b>°</b>C, 14<b>°</b>C, and 24<b>°</b>C. Depth-of-interaction (DOI) resolution was evaluated at the optimal bias voltage determined from the flood histogram and at all three temperatures.<i>Main results.</i>Temperature had a negligible effect on detector performance, indicating that CRL PS-SiPMs are practical photodetector candidates for high spatial resolution PET scanners. All LYSO crystals were clearly resolved in the flood histograms. At 24<b>°</b>C and a bias voltage of 32.5 V, which provided the best flood histogram, the average energy resolution, CTR, and DOI resolution across all crystals were 22.7 ± 3.4%, 1152 ± 43 ps, and 1.78 ± 0.20 mm, respectively.<i>Significance.</i>These results demonstrate that CRL PS-SiPMs are promising photodetectors for high spatial resolution PET applications, particularly for systems requiring detectors with sub-millimeter pitch scintillator crystal arrays and DOI capability.</p>","PeriodicalId":20185,"journal":{"name":"Physics in medicine and biology","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2026-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics in medicine and biology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6560/ae9a28","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Objective.Continuous resistive layer position-sensitive silicon photomultiplier (CRL PS-SiPM) is a class of position-sensitive SiPMs developed for the readout of fine-pitch scintillator crystal arrays. This study aimed to evaluate the performance of dual-ended readout positron emission tomography (PET) detectors based on CRL PS-SiPMs and 0.5 mm pitch LYSO arrays.Approach.A dual-ended readout detector was constructed by coupling two CRL PS-SiPMs to both ends of a 10 × 10 array of polished LYSO elements, each measuring 0.44 × 0.44 × 20 mm3. Each CRL PS-SiPM had an active area of 6.24 × 6.24 mm2and was fabricated using 20µm microcells. Detector performance, including flood histogram quality, energy resolution, and coincidence timing resolution (CTR), was characterized at bias voltages ranging from 30.0 to 33.0 V in 0.5 V increments, and at 3°C, 14°C, and 24°C. Depth-of-interaction (DOI) resolution was evaluated at the optimal bias voltage determined from the flood histogram and at all three temperatures.Main results.Temperature had a negligible effect on detector performance, indicating that CRL PS-SiPMs are practical photodetector candidates for high spatial resolution PET scanners. All LYSO crystals were clearly resolved in the flood histograms. At 24°C and a bias voltage of 32.5 V, which provided the best flood histogram, the average energy resolution, CTR, and DOI resolution across all crystals were 22.7 ± 3.4%, 1152 ± 43 ps, and 1.78 ± 0.20 mm, respectively.Significance.These results demonstrate that CRL PS-SiPMs are promising photodetectors for high spatial resolution PET applications, particularly for systems requiring detectors with sub-millimeter pitch scintillator crystal arrays and DOI capability.
期刊介绍:
The development and application of theoretical, computational and experimental physics to medicine, physiology and biology. Topics covered are: therapy physics (including ionizing and non-ionizing radiation); biomedical imaging (e.g. x-ray, magnetic resonance, ultrasound, optical and nuclear imaging); image-guided interventions; image reconstruction and analysis (including kinetic modelling); artificial intelligence in biomedical physics and analysis; nanoparticles in imaging and therapy; radiobiology; radiation protection and patient dose monitoring; radiation dosimetry