Thermal Risk During Bivalving of Fiberglass Casts Following Orthopaedic Reduction: A Comparative Analysis of 2 Commercially Available Cast Padding Products.

IF 1.7 3区 医学 Q3 ORTHOPEDICS
Journal of Pediatric Orthopaedics Pub Date : 2026-11-01 Epub Date: 2026-08-17 DOI:10.1097/BPO.0000000000003442
Claire A Donnelley, Aiden Reuter, James E Donnelley, Peter C Noback, Steven Tommasini, Xuan Luo
{"title":"Thermal Risk During Bivalving of Fiberglass Casts Following Orthopaedic Reduction: A Comparative Analysis of 2 Commercially Available Cast Padding Products.","authors":"Claire A Donnelley, Aiden Reuter, James E Donnelley, Peter C Noback, Steven Tommasini, Xuan Luo","doi":"10.1097/BPO.0000000000003442","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Cast saw burns (CSBs) are a preventable, iatrogenic complication that may occur during bivalving or removal of fiberglass casts. Children undergoing fracture reduction with the use of procedural sedation, typically in the emergency department (ED), are at heightened risk for CSBs because they cannot provide real-time pain feedback during cast saw use. While prior investigations have examined the effects of cast material, cast thickness, and water dip temperature, the comparative thermal performance of commercially available cast padding products during cast bivalving has not been systematically evaluated. This study used thermal probes to compare measured temperatures beneath 2 widely used cast padding products, Webril (Kendall/Cardinal Health) and Specialist (BSN Medical), during a standardized cast application, molding, and bivalving protocol.</p><p><strong>Methods: </strong>A custom upper-extremity model was instrumented with 2 calibrated thermocouples (labeled \"near\" and \"far\"). Twenty experimental runs were performed, 10 each per padding product, with bivalving performed separately for near and far probes (N=40 total). Temperatures were recorded at 3 time points: baseline (before the application of any materials), prebivalve (immediately after fiberglass application ), and at maximum temperature during bivalving with an oscillating cast saw. The primary outcome was the change in temperature from prebivalve to maximum bivalve temperature (ΔT) measured by near and far probes. Secondary outcome included maximum temperatures relative to established burn injury thresholds.</p><p><strong>Results: </strong>The mean ΔT during bivalving was 13.2±13.0°C for Specialist padding and 13.0±6.9°C for Webril padding ( P =0.95). The mean absolute maximum temperature was 40.8±13.2°C for Specialist and 39.5±6.8°C for Webril. In the Specialist group, 6/10 runs exceeded the 44°C adult burn threshold on at least one probe, compared with 4/10 runs in the Webril group. Linear mixed-effects analysis with Kenward-Roger degrees of freedom revealed a significant material×probe interaction during bivalving ( P =0.020): at the near probe, Specialist peak temperatures averaged 8.5°C higher than Webril ( P =0.041), whereas the 2 materials did not differ significantly at the far probe ( P =0.146).</p><p><strong>Conclusion: </strong>Maximum temperatures exceeded clinically relevant burn thresholds in both cast padding groups, supporting the high-risk thermal environment at cast mold sites during bivalving. While Webril had some protective effect, neither commercially available cast-padding product provided consistently sufficient or statistically superior thermal protection.</p><p><strong>Levels of evidence: </strong>Not applicable (biomechanical study).</p>","PeriodicalId":16945,"journal":{"name":"Journal of Pediatric Orthopaedics","volume":" ","pages":"e997-e1003"},"PeriodicalIF":1.7000,"publicationDate":"2026-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pediatric Orthopaedics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/BPO.0000000000003442","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/17 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Cast saw burns (CSBs) are a preventable, iatrogenic complication that may occur during bivalving or removal of fiberglass casts. Children undergoing fracture reduction with the use of procedural sedation, typically in the emergency department (ED), are at heightened risk for CSBs because they cannot provide real-time pain feedback during cast saw use. While prior investigations have examined the effects of cast material, cast thickness, and water dip temperature, the comparative thermal performance of commercially available cast padding products during cast bivalving has not been systematically evaluated. This study used thermal probes to compare measured temperatures beneath 2 widely used cast padding products, Webril (Kendall/Cardinal Health) and Specialist (BSN Medical), during a standardized cast application, molding, and bivalving protocol.

Methods: A custom upper-extremity model was instrumented with 2 calibrated thermocouples (labeled "near" and "far"). Twenty experimental runs were performed, 10 each per padding product, with bivalving performed separately for near and far probes (N=40 total). Temperatures were recorded at 3 time points: baseline (before the application of any materials), prebivalve (immediately after fiberglass application ), and at maximum temperature during bivalving with an oscillating cast saw. The primary outcome was the change in temperature from prebivalve to maximum bivalve temperature (ΔT) measured by near and far probes. Secondary outcome included maximum temperatures relative to established burn injury thresholds.

Results: The mean ΔT during bivalving was 13.2±13.0°C for Specialist padding and 13.0±6.9°C for Webril padding ( P =0.95). The mean absolute maximum temperature was 40.8±13.2°C for Specialist and 39.5±6.8°C for Webril. In the Specialist group, 6/10 runs exceeded the 44°C adult burn threshold on at least one probe, compared with 4/10 runs in the Webril group. Linear mixed-effects analysis with Kenward-Roger degrees of freedom revealed a significant material×probe interaction during bivalving ( P =0.020): at the near probe, Specialist peak temperatures averaged 8.5°C higher than Webril ( P =0.041), whereas the 2 materials did not differ significantly at the far probe ( P =0.146).

Conclusion: Maximum temperatures exceeded clinically relevant burn thresholds in both cast padding groups, supporting the high-risk thermal environment at cast mold sites during bivalving. While Webril had some protective effect, neither commercially available cast-padding product provided consistently sufficient or statistically superior thermal protection.

Levels of evidence: Not applicable (biomechanical study).

骨科复位后玻璃纤维铸件分瓣时的热风险:两种市售铸件填充物的比较分析。
背景:铸造锯烧伤(CSBs)是一种可预防的医源性并发症,可能发生在玻璃纤维铸件切开或取出过程中。通常在急诊科(ED)使用程序性镇静进行骨折复位的儿童发生csb的风险更高,因为他们在使用石膏锯时无法提供实时疼痛反馈。虽然之前的研究已经考察了铸件材料、铸件厚度和浸水温度的影响,但在铸态双阀化过程中,市面上可买到的铸态填料产品的相对热性能还没有得到系统的评估。本研究使用热探针比较了两种广泛使用的铸造填充产品(Webril (Kendall/Cardinal Health)和Specialist (BSN Medical))在标准化铸造应用、成型和双阀方案下的测量温度。方法:定制上肢模型,使用2个校准的热电偶(标记为“近”和“远”)。共进行了20次实验,每种填充产品各10次,近探针和远探针分别进行双阀化(N=40)。在3个时间点记录温度:基线(应用任何材料之前),双瓣前(应用玻璃纤维后),以及使用摆动铸锯进行双瓣时的最高温度。主要结果是由近端和远端探针测量的温度从双瓣前到最高双瓣温度(ΔT)的变化。次要结果包括相对于已确定的烧伤阈值的最高温度。结果:双瓣分娩期的平均ΔT为Specialist填充13.2±13.0°C, Webril填充13.0±6.9°C (P=0.95)。Specialist的平均绝对最高温度为40.8±13.2℃,Webril的平均绝对最高温度为39.5±6.8℃。在Specialist组中,6/10组至少在一个探针上超过44°C成人烧伤阈值,而Webril组为4/10组。采用Kenward-Roger自由度的线性混合效应分析显示,双瓣过程中存在显著的material×probe相互作用(P=0.020):在近探针处,Specialist峰值温度平均比Webril高8.5°C (P=0.041),而在远探针处,这两种材料没有显著差异(P=0.146)。结论:两组铸型填充物的最高温度均超过临床相关的烧伤阈值,支持分瓣过程中铸型部位的高危热环境。虽然Webril有一定的保护作用,但两种市售的浇铸填充产品都不能提供足够的热保护,也不能提供统计上更好的热保护。证据水平:不适用(生物力学研究)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.30
自引率
17.60%
发文量
512
审稿时长
6 months
期刊介绍: ​Journal of Pediatric Orthopaedics is a leading journal that focuses specifically on traumatic injuries to give you hands-on on coverage of a fast-growing field. You''ll get articles that cover everything from the nature of injury to the effects of new drug therapies; everything from recommendations for more effective surgical approaches to the latest laboratory findings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书