Artificial intelligence-based systems as auxiliary tools for thyroid nodule malignancy detection on ultrasound: a systematic review and meta-analysis of diagnostic accuracy.

IF 1.9 3区 医学 Q3 SURGERY
Gland surgery Pub Date : 2026-07-31 Epub Date: 2026-06-26 DOI:10.21037/gs-2026-1-0126
Rafael De Cicco, Francisco Araujo Dias, Victor Bandini Vieira, Rafael Souza, Tabata Briaunys Milan
{"title":"Artificial intelligence-based systems as auxiliary tools for thyroid nodule malignancy detection on ultrasound: a systematic review and meta-analysis of diagnostic accuracy.","authors":"Rafael De Cicco, Francisco Araujo Dias, Victor Bandini Vieira, Rafael Souza, Tabata Briaunys Milan","doi":"10.21037/gs-2026-1-0126","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Artificial intelligence (AI)-based systems are valuable tools in thyroid nodule diagnosis, but clinical controversy remains regarding diagnostic inconsistency and specificity. This meta-analysis evaluated the diagnostic accuracy of AI-assisted ultrasound systems for detecting malignant thyroid nodules compared to radiologists and risk stratification systems.</p><p><strong>Methods: </strong>Guided by the PICOS (Population, Intervention, Comparison, Outcome, Study Design) framework, a systematic search across PubMed, Semantic Scholar, and OpenAlex identified 69 studies using histopathological or cytological reference standards. Quality and Risk of Bias were assessed via an AI-tailored QUADAS-2 tool. Pooled sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were calculated using bivariate random-effects meta-analysis.</p><p><strong>Results: </strong>The 69 studies evaluated >350,000 nodules. AI-based systems demonstrated high diagnostic accuracy: pooled sensitivity 89% [95% confidence interval (CI): 87-91%], specificity 84% (95% CI: 80-88%), and AUC 0.93 (95% CI: 0.91-0.95). In direct comparisons, AI systems achieved comparable or superior performance to experienced radiologists (AUC 0.90-0.95 <i>vs.</i> 0.76-0.86). AI significantly improved specificity over individual radiologists and systems like ACR TI-RADS. AI-optimized TI-RADS achieved higher specificity (70.2% <i>vs.</i> 49.2%, P<0.001) than standard ACR TI-RADS with similar sensitivity. Consequently, AI-assisted strategies reduced unnecessary fine-needle aspirations (FNAs) by up to 26.7 percentage points. Performance peaked for nodules <20 mm and in externally validated, multicenter settings. AI provided the greatest incremental benefit for less experienced practitioners, markedly improving interobserver agreement.</p><p><strong>Conclusions: </strong>AI systems achieve high diagnostic accuracy for thyroid nodule malignancy, demonstrating performance comparable or superior to radiologists and risk stratification frameworks. As adjunctive tools, they safely reduce unnecessary biopsies and improve diagnostic consistency. Future clinical integration must prioritize multimodal data and radiomics to maximize utility.</p>","PeriodicalId":12760,"journal":{"name":"Gland surgery","volume":"15 7","pages":"186"},"PeriodicalIF":1.9000,"publicationDate":"2026-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13462842/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gland surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21037/gs-2026-1-0126","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/26 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Artificial intelligence (AI)-based systems are valuable tools in thyroid nodule diagnosis, but clinical controversy remains regarding diagnostic inconsistency and specificity. This meta-analysis evaluated the diagnostic accuracy of AI-assisted ultrasound systems for detecting malignant thyroid nodules compared to radiologists and risk stratification systems.

Methods: Guided by the PICOS (Population, Intervention, Comparison, Outcome, Study Design) framework, a systematic search across PubMed, Semantic Scholar, and OpenAlex identified 69 studies using histopathological or cytological reference standards. Quality and Risk of Bias were assessed via an AI-tailored QUADAS-2 tool. Pooled sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were calculated using bivariate random-effects meta-analysis.

Results: The 69 studies evaluated >350,000 nodules. AI-based systems demonstrated high diagnostic accuracy: pooled sensitivity 89% [95% confidence interval (CI): 87-91%], specificity 84% (95% CI: 80-88%), and AUC 0.93 (95% CI: 0.91-0.95). In direct comparisons, AI systems achieved comparable or superior performance to experienced radiologists (AUC 0.90-0.95 vs. 0.76-0.86). AI significantly improved specificity over individual radiologists and systems like ACR TI-RADS. AI-optimized TI-RADS achieved higher specificity (70.2% vs. 49.2%, P<0.001) than standard ACR TI-RADS with similar sensitivity. Consequently, AI-assisted strategies reduced unnecessary fine-needle aspirations (FNAs) by up to 26.7 percentage points. Performance peaked for nodules <20 mm and in externally validated, multicenter settings. AI provided the greatest incremental benefit for less experienced practitioners, markedly improving interobserver agreement.

Conclusions: AI systems achieve high diagnostic accuracy for thyroid nodule malignancy, demonstrating performance comparable or superior to radiologists and risk stratification frameworks. As adjunctive tools, they safely reduce unnecessary biopsies and improve diagnostic consistency. Future clinical integration must prioritize multimodal data and radiomics to maximize utility.

基于人工智能的系统作为超声甲状腺结节恶性肿瘤检测的辅助工具:诊断准确性的系统回顾和荟萃分析。
背景:基于人工智能(AI)的系统是甲状腺结节诊断的重要工具,但在诊断的不一致性和特异性方面仍存在临床争议。与放射科医生和风险分层系统相比,本荟萃分析评估了人工智能辅助超声系统检测恶性甲状腺结节的诊断准确性。方法:在PICOS(人群、干预、比较、结果、研究设计)框架的指导下,通过PubMed、Semantic Scholar和OpenAlex进行系统搜索,确定了69项使用组织病理学或细胞学参考标准的研究。通过人工智能定制的QUADAS-2工具评估偏倚的质量和风险。采用双变量随机效应荟萃分析计算合并敏感性、特异性和受试者工作特征曲线下面积(AUC)。结果:69项研究评估了约35万个结节。基于人工智能的系统显示出较高的诊断准确性:合并灵敏度89%[95%置信区间(CI): 87-91%],特异性84% (95% CI: 80-88%), AUC 0.93 (95% CI: 0.91-0.95)。在直接比较中,人工智能系统的表现与经验丰富的放射科医生相当或更好(AUC 0.90-0.95 vs. 0.76-0.86)。人工智能显著提高了个体放射科医生和ACR TI-RADS等系统的特异性。人工智能优化的TI-RADS具有更高的特异性(70.2% vs. 49.2%)。结论:人工智能系统对甲状腺结节恶性肿瘤具有较高的诊断准确性,其表现与放射科医生和风险分层框架相当或优于放射科医生。作为辅助工具,它们可以安全地减少不必要的活检并提高诊断的一致性。未来的临床整合必须优先考虑多模式数据和放射组学,以最大限度地发挥效用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Gland surgery
Gland surgery Medicine-Surgery
CiteScore
3.60
自引率
0.00%
发文量
113
期刊介绍: Gland Surgery (Gland Surg; GS, Print ISSN 2227-684X; Online ISSN 2227-8575) being indexed by PubMed/PubMed Central, is an open access, peer-review journal launched at May of 2012, published bio-monthly since February 2015.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书