Pulse Index Continuous Cardiac Output-Guided Hemodynamic Therapy in Living Donor Kidney Transplantation: A Prospective Cohort Study.

IF 2.2 Q2 MEDICINE, GENERAL & INTERNAL
Journal of clinical medicine research Pub Date : 2026-07-31 eCollection Date: 2026-07-01 DOI:10.14740/jocmr6632
Van Dung Le, Huu Tu Nguyen, Quang Thuy Luu, Minh Hoang Thach, Thi Thuy Trang Tran, Van Dong Pham, Francis Zamora, Gary Ta-Wei Yu, Viet Hoang Dinh
{"title":"Pulse Index Continuous Cardiac Output-Guided Hemodynamic Therapy in Living Donor Kidney Transplantation: A Prospective Cohort Study.","authors":"Van Dung Le, Huu Tu Nguyen, Quang Thuy Luu, Minh Hoang Thach, Thi Thuy Trang Tran, Van Dong Pham, Francis Zamora, Gary Ta-Wei Yu, Viet Hoang Dinh","doi":"10.14740/jocmr6632","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Central venous pressure (CVP)-guided fluid therapy remains common during kidney transplantation, although CVP is a static marker with limited ability to predict fluid responsiveness. This prospective observational cohort study evaluated whether pulse index continuous cardiac output-guided goal-directed hemodynamic therapy (GDHT), using dynamic and volumetric hemodynamic variables, was associated with improved early graft function compared with conventional CVP-guided management in living donor kidney transplantation.</p><p><strong>Methods: </strong>Eighty living donor kidney transplant recipients at Cho Ray Hospital, Vietnam, were enrolled between May 2024 and December 2025. Patients were managed according to the institutional anesthetic monitoring protocol in use at the time of surgery: CVP-guided fluid therapy (group C, n = 40) or PiCCO-guided GDHT (group P, n = 40). The PiCCO protocol incorporated stroke volume variation, pulse pressure variation, cardiac index, global end-diastolic volume index, systemic vascular resistance index, and extravascular lung water index. Outcomes included intraoperative fluid volume, vasopressor use, postoperative urine output, serum creatinine through postoperative day 7, delayed graft function, and postoperative complications.</p><p><strong>Results: </strong>Baseline recipient, donor, and operative characteristics were comparable between groups, with the exception of cold ischemia time, which was longer in group P. Total intraoperative fluid volume was lower in group P than in group C (2,656 ± 480 mL vs. 3,097 ± 555 mL; P = 0.001), and vasopressor use was numerically lower but not statistically significant (12.5% vs. 27.5%; Fisher's exact P = 0.161). First-hour postoperative urine output was higher in group P (1,235 ± 162 mL vs. 1,010 ± 315 mL; P < 0.001). Serum creatinine was similar on postoperative day 1 but was significantly lower in group P on day 3 (1.3 (0.8-1.8) mg/dL vs. 1.6 (1.4-1.9) mg/dL; P = 0.036); the difference on day 7 was not statistically significant (1.1 (0.7-1.4) mg/dL vs. 1.3 (1.1-2.1) mg/dL; P = 0.16). No patient in either group developed delayed graft function within 7 days. Extravascular lung water index remained within the reference range during surgery, and no patient developed clinical pulmonary edema.</p><p><strong>Conclusions: </strong>In this prospective cohort, PiCCO-guided GDHT was associated with lower intraoperative fluid administration, numerically lower vasopressor use, and faster early recovery of graft function after living donor kidney transplantation. These findings support further evaluation of multiparameter hemodynamic monitoring as an individualized perioperative strategy in kidney transplantation.</p>","PeriodicalId":94329,"journal":{"name":"Journal of clinical medicine research","volume":"18 7","pages":"456-464"},"PeriodicalIF":2.2000,"publicationDate":"2026-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13456939/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical medicine research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14740/jocmr6632","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Central venous pressure (CVP)-guided fluid therapy remains common during kidney transplantation, although CVP is a static marker with limited ability to predict fluid responsiveness. This prospective observational cohort study evaluated whether pulse index continuous cardiac output-guided goal-directed hemodynamic therapy (GDHT), using dynamic and volumetric hemodynamic variables, was associated with improved early graft function compared with conventional CVP-guided management in living donor kidney transplantation.

Methods: Eighty living donor kidney transplant recipients at Cho Ray Hospital, Vietnam, were enrolled between May 2024 and December 2025. Patients were managed according to the institutional anesthetic monitoring protocol in use at the time of surgery: CVP-guided fluid therapy (group C, n = 40) or PiCCO-guided GDHT (group P, n = 40). The PiCCO protocol incorporated stroke volume variation, pulse pressure variation, cardiac index, global end-diastolic volume index, systemic vascular resistance index, and extravascular lung water index. Outcomes included intraoperative fluid volume, vasopressor use, postoperative urine output, serum creatinine through postoperative day 7, delayed graft function, and postoperative complications.

Results: Baseline recipient, donor, and operative characteristics were comparable between groups, with the exception of cold ischemia time, which was longer in group P. Total intraoperative fluid volume was lower in group P than in group C (2,656 ± 480 mL vs. 3,097 ± 555 mL; P = 0.001), and vasopressor use was numerically lower but not statistically significant (12.5% vs. 27.5%; Fisher's exact P = 0.161). First-hour postoperative urine output was higher in group P (1,235 ± 162 mL vs. 1,010 ± 315 mL; P < 0.001). Serum creatinine was similar on postoperative day 1 but was significantly lower in group P on day 3 (1.3 (0.8-1.8) mg/dL vs. 1.6 (1.4-1.9) mg/dL; P = 0.036); the difference on day 7 was not statistically significant (1.1 (0.7-1.4) mg/dL vs. 1.3 (1.1-2.1) mg/dL; P = 0.16). No patient in either group developed delayed graft function within 7 days. Extravascular lung water index remained within the reference range during surgery, and no patient developed clinical pulmonary edema.

Conclusions: In this prospective cohort, PiCCO-guided GDHT was associated with lower intraoperative fluid administration, numerically lower vasopressor use, and faster early recovery of graft function after living donor kidney transplantation. These findings support further evaluation of multiparameter hemodynamic monitoring as an individualized perioperative strategy in kidney transplantation.

脉搏指数连续心输出量引导血流动力学治疗活体肾移植:一项前瞻性队列研究。
背景:中心静脉压(CVP)引导的液体治疗在肾移植中仍然很常见,尽管CVP是一个静态标记物,预测液体反应的能力有限。这项前瞻性观察队列研究评估了在活体肾移植中,与传统的cvp引导治疗相比,脉搏指数连续心输出量引导下的目标导向血流动力学治疗(GDHT)是否与早期移植物功能改善有关。方法:在2024年5月至2025年12月期间,在越南Cho Ray医院登记了80名活体肾移植受者。患者根据手术时使用的机构麻醉监测方案进行管理:cvp引导的液体治疗(C组,n = 40)或picco引导的GDHT (P组,n = 40)。PiCCO方案纳入了脑卒中容积变化、脉压变化、心脏指数、整体舒张末期容积指数、全身血管阻力指数和血管外肺水指数。结果包括术中液体量、血管加压剂使用、术后尿量、术后第7天血清肌酐、移植物功能延迟和术后并发症。结果:各组之间的基线受体、供体和手术特征是相似的,除了冷缺血时间,P组更长,P组术中总液量低于C组(2,656±480 mL比3,097±555 mL, P = 0.001),血管加压剂的使用数值较低,但无统计学意义(12.5%比27.5%;Fisher精确P = 0.161)。P组术后第1小时尿量较高(1,235±162 mL比1,010±315 mL; P < 0.001)。P组术后第1天血清肌酐相似,但第3天显著低于P组(1.3 (0.8-1.8)mg/dL vs. 1.6 (1.4-1.9) mg/dL;P = 0.036);第7天差异无统计学意义(1.1 (0.7-1.4)mg/dL vs. 1.3 (1.1-2.1) mg/dL;P = 0.16)。两组患者均未在7天内出现移植物功能延迟。术中肺血管外水指数保持在参考范围内,无患者出现临床肺水肿。结论:在这个前瞻性队列中,picco引导下的GDHT与术中液体给药量低、血管加压剂用量低、活体肾移植后移植功能早期恢复更快相关。这些发现支持进一步评价多参数血流动力学监测作为肾移植围手术期个体化策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书