Three-dimensional position reconstruction of a cascade gamma ray-emitting source based on geometric back-projection through the angle of incidence

IF 1 4区 物理与天体物理 Q3 PHYSICS, MULTIDISCIPLINARY
Leonid L. Nkuba, Enock M. Mwita, Innocent J. Junior, Elisha E. Edmund, Innocent J. Lugendo
{"title":"Three-dimensional position reconstruction of a cascade gamma ray-emitting source based on geometric back-projection through the angle of incidence","authors":"Leonid L. Nkuba,&nbsp;Enock M. Mwita,&nbsp;Innocent J. Junior,&nbsp;Elisha E. Edmund,&nbsp;Innocent J. Lugendo","doi":"10.1007/s40042-026-01645-1","DOIUrl":null,"url":null,"abstract":"<div><p>A novel technique has been developed to determine the three-dimensional position of a source emitting multiple cascade γ-rays with sub-millimeter accuracy using dual-layered GSO (Ce) scintillation detectors. This method reconstructs the source position by processing filtered energy and detector hit positions through a back-projection algorithm along the paths of incident γ-rays. The detector array and an <sup>111</sup>In-ion point source at five locations within the central detection volume were simulated using the GATE Monte Carlo framework. For a source at the detector center (0, 0, 0), the reconstructed coordinates are − 0.001 mm, − 0.001 mm, and − 0.001 mm along X, Y, and Z. This indicates that the reconstructed source centroid was centrally located and well within the spatial resolution limits of the detector system. For other simulated source positions, the reconstructed coordinates matched approximately 99.8% of the actual simulated positions, although some positions varied between 70.9% and 125% of the true values. Except for source at the center, other source positions were reported with uncertainty ranging from 0.006 × 10<sup>–3</sup> mm to ± 5.480 × 10<sup>–3</sup> mm. While reconstruction at the transaxial and axial edges is less precise due to limited valid coincidence events, the results demonstrate the method’s robustness. The achieved reconstruction precision indicates potential applications in nuclear medicine, nuclear security, radioactive waste assay, and proton beam therapy.</p></div>","PeriodicalId":677,"journal":{"name":"Journal of the Korean Physical Society","volume":"89 4","pages":"325 - 334"},"PeriodicalIF":1.0000,"publicationDate":"2026-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s40042-026-01645-1.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Korean Physical Society","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1007/s40042-026-01645-1","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PHYSICS, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

A novel technique has been developed to determine the three-dimensional position of a source emitting multiple cascade γ-rays with sub-millimeter accuracy using dual-layered GSO (Ce) scintillation detectors. This method reconstructs the source position by processing filtered energy and detector hit positions through a back-projection algorithm along the paths of incident γ-rays. The detector array and an 111In-ion point source at five locations within the central detection volume were simulated using the GATE Monte Carlo framework. For a source at the detector center (0, 0, 0), the reconstructed coordinates are − 0.001 mm, − 0.001 mm, and − 0.001 mm along X, Y, and Z. This indicates that the reconstructed source centroid was centrally located and well within the spatial resolution limits of the detector system. For other simulated source positions, the reconstructed coordinates matched approximately 99.8% of the actual simulated positions, although some positions varied between 70.9% and 125% of the true values. Except for source at the center, other source positions were reported with uncertainty ranging from 0.006 × 10–3 mm to ± 5.480 × 10–3 mm. While reconstruction at the transaxial and axial edges is less precise due to limited valid coincidence events, the results demonstrate the method’s robustness. The achieved reconstruction precision indicates potential applications in nuclear medicine, nuclear security, radioactive waste assay, and proton beam therapy.

基于入射角几何背投影的级联伽马射线源三维位置重建
本文提出了一种利用双层GSO (Ce)闪烁探测器以亚毫米精度确定多级γ射线发射源的三维位置的新技术。该方法通过沿入射γ射线路径的反投影算法,对滤波后的能量和探测器命中位置进行处理,重建源位置。利用GATE蒙特卡罗框架对探测器阵列和中心探测体内5个位置的111in离子点源进行了模拟。对于位于探测器中心(0,0,0)的源,沿X, Y和z的重建坐标分别为- 0.001 mm, - 0.001 mm和- 0.001 mm,这表明重建的源质心位于中心,并且在探测器系统的空间分辨率限制内。对于其他模拟震源位置,重建的坐标与实际模拟位置的匹配度约为99.8%,尽管有些位置的匹配度在70.9%到125%之间。除中心源外,其他源位置的不确定度范围为0.006 × 10-3 mm至±5.480 × 10-3 mm。虽然由于有效重合事件的限制,在轴向和轴向边缘的重建精度较低,但结果表明该方法具有鲁棒性。所获得的重建精度表明在核医学、核安全、放射性废物分析和质子束治疗方面有潜在的应用前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of the Korean Physical Society
Journal of the Korean Physical Society PHYSICS, MULTIDISCIPLINARY-
CiteScore
1.20
自引率
16.70%
发文量
276
审稿时长
5.5 months
期刊介绍: The Journal of the Korean Physical Society (JKPS) covers all fields of physics spanning from statistical physics and condensed matter physics to particle physics. The manuscript to be published in JKPS is required to hold the originality, significance, and recent completeness. The journal is composed of Full paper, Letters, and Brief sections. In addition, featured articles with outstanding results are selected by the Editorial board and introduced in the online version. For emphasis on aspect of international journal, several world-distinguished researchers join the Editorial board. High quality of papers may be express-published when it is recommended or requested.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书