Clinical Outcomes of Tilted Implants in the Atrophic Posterior Mandible: A Long-Term Study.

IF 1.3
Norika Kuneshita, Ryo Kajihara, Hironori Sakai, Hiroki Otagiri, Yuji Kusafuka, Hiroshi Kurita
{"title":"Clinical Outcomes of Tilted Implants in the Atrophic Posterior Mandible: A Long-Term Study.","authors":"Norika Kuneshita, Ryo Kajihara, Hironori Sakai, Hiroki Otagiri, Yuji Kusafuka, Hiroshi Kurita","doi":"10.1563/aaid-joi-D-25-00078","DOIUrl":null,"url":null,"abstract":"<p><p>Implant treatment for atrophic mandibular molars is challenging due to limited space for implant placement and the potential risk of damaging the inferior alveolar nerve. One approach to address these challenges is the angled placement of endosseous implants. We herein report the long-term outcomes of tilted implants placed in atrophic mandibles. Subjects were 12 patients who underwent intentionally tilted implant placement in the atrophic posterior mandible in our department between 2006 and 2014, and 28 implants were placed. Patients were scheduled for follow-up visits every 6 months for a clinical assessment. The minimum observation period was 7.4 years, and the maximum was 16.3 years. Vertical bone loss was monitored on follow-up panoramic radiographs with vertical bone resorption ≥3 mm included in the evaluation. Three implants (in 2 patients) were placed with bone grafting. Twenty implants had single crowns, and 8 were splinted. A radiographic assessment revealed vertical bone resorption ≥3 mm in 7 implants (25%). The 10-year cumulative survival rate was 96.4% (1 implant lost in 9.3 years). There was no damage to the neurovascular structure or permanent paresthesia. Although the rate of vertical bone resorption was high, the prognosis of tilted placement in the mandibular molar region was favorable, suggesting it has potential as a good treatment option to reduce the risk of inferior alveolar nerve damage.</p>","PeriodicalId":519890,"journal":{"name":"The Journal of oral implantology","volume":"52 4","pages":"271-275"},"PeriodicalIF":1.3000,"publicationDate":"2026-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of oral implantology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1563/aaid-joi-D-25-00078","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Implant treatment for atrophic mandibular molars is challenging due to limited space for implant placement and the potential risk of damaging the inferior alveolar nerve. One approach to address these challenges is the angled placement of endosseous implants. We herein report the long-term outcomes of tilted implants placed in atrophic mandibles. Subjects were 12 patients who underwent intentionally tilted implant placement in the atrophic posterior mandible in our department between 2006 and 2014, and 28 implants were placed. Patients were scheduled for follow-up visits every 6 months for a clinical assessment. The minimum observation period was 7.4 years, and the maximum was 16.3 years. Vertical bone loss was monitored on follow-up panoramic radiographs with vertical bone resorption ≥3 mm included in the evaluation. Three implants (in 2 patients) were placed with bone grafting. Twenty implants had single crowns, and 8 were splinted. A radiographic assessment revealed vertical bone resorption ≥3 mm in 7 implants (25%). The 10-year cumulative survival rate was 96.4% (1 implant lost in 9.3 years). There was no damage to the neurovascular structure or permanent paresthesia. Although the rate of vertical bone resorption was high, the prognosis of tilted placement in the mandibular molar region was favorable, suggesting it has potential as a good treatment option to reduce the risk of inferior alveolar nerve damage.

倾斜种植体治疗萎缩后下颌骨的临床效果:一项长期研究。
由于种植体放置空间有限,并且有损伤下牙槽神经的潜在风险,种植体治疗萎缩的下颌磨牙是具有挑战性的。解决这些问题的一种方法是有角度地放置骨内植入物。我们在此报告倾斜种植体放置在萎缩性下颌骨的长期结果。研究对象为我科2006 - 2014年间在萎缩后下颌骨进行有意倾斜种植体植入的12例患者,共植入28颗种植体。患者每6个月随访一次,进行临床评估。最小观测周期为7.4 a,最大观测周期为16.3 a。随访全景x线片监测垂直骨丢失情况,评估纳入垂直骨吸收≥3mm。3个种植体(2例)与骨移植一起放置。20个种植体为单冠,8个为夹板。x线评估显示7个种植体(25%)垂直骨吸收≥3mm。10年累计生存率为96.4%(9.3年丢失1个种植体)。无神经血管结构损伤或永久性感觉异常。虽然垂直骨吸收率高,但下颌磨牙区倾斜放置的预后良好,提示其有潜力作为降低下牙槽神经损伤风险的良好治疗选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书