Effect of distal screw number on axial deformation and fragment-specific stability in AO/OTA 2R3 C2.1 distal radius fractures

IF 2.2 3区 医学 Q2 ORTHOPEDICS
Lena Dietz, Christian Spiegel, Felix Christian Kohler, Uta Biedermann, Ivan Zderic, Alicia Feist, Boyko Gueorguiev-Rüegg, Mark Lenz, Wolfram Weschenfelder
{"title":"Effect of distal screw number on axial deformation and fragment-specific stability in AO/OTA 2R3 C2.1 distal radius fractures","authors":"Lena Dietz,&nbsp;Christian Spiegel,&nbsp;Felix Christian Kohler,&nbsp;Uta Biedermann,&nbsp;Ivan Zderic,&nbsp;Alicia Feist,&nbsp;Boyko Gueorguiev-Rüegg,&nbsp;Mark Lenz,&nbsp;Wolfram Weschenfelder","doi":"10.1007/s00402-026-06454-6","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>To investigate the biomechanical influence of distal screw number in palmar plate fixation of unstable intra-articular distal radius fractures with radiodorsal metaphyseal comminution.</p><h3>Methods</h3><p>Nine matched pairs of cryopreserved human radii were prepared using a standardized AO/OTA 2R3 C2.1 fracture model with a defined radiodorsal metaphyseal defect zone. For each pair, specimens were randomized to palmar fixation using a 2.4-mm variable-angle locking plate with either four or six distal screws. After embedding, constructs were subjected to cyclic axial loading (150 N, 5,000 cycles) simulating early postoperative rehabilitation. Global axial deformation and fragment-specific three-dimensional interfragmentary motion were recorded using an optical motion-tracking system. Statistical analysis was performed using non-parametric tests (<i>p</i> &lt; 0.05).</p><h3>Results</h3><p>Two specimens from one donor pair were excluded, leaving 16 radii (8 pairs) for analysis. Bone mineral density and initial construct stiffness did not differ between groups. The six-screw configuration showed significantly lower axial deformation after cyclic loading (<i>p</i> = 0.047) and lower radial fragment–shaft translation at both time points (<i>p</i> = 0.028; <i>p</i> = 0.045). Radial fragment–shaft rotation was lower in the six-screw group at baseline (<i>p</i> = 0.018), but no rotational difference remained after cyclic loading. In the overall cohort, axial deformation decreased after cyclic loading (<i>p</i> = 0.015).</p><h3>Conclusion</h3><p>In this unstable intra-articular fracture model with radiodorsal metaphyseal comminution, six distal screws reduced post-cyclic axial deformation and radial fragment–shaft micromotion compared with four screws. The clinical relevance of these findings remains to be determined.</p></div>","PeriodicalId":8326,"journal":{"name":"Archives of Orthopaedic and Trauma Surgery","volume":"146 1","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2026-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s00402-026-06454-6.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Orthopaedic and Trauma Surgery","FirstCategoryId":"3","ListUrlMain":"https://link.springer.com/article/10.1007/s00402-026-06454-6","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

To investigate the biomechanical influence of distal screw number in palmar plate fixation of unstable intra-articular distal radius fractures with radiodorsal metaphyseal comminution.

Methods

Nine matched pairs of cryopreserved human radii were prepared using a standardized AO/OTA 2R3 C2.1 fracture model with a defined radiodorsal metaphyseal defect zone. For each pair, specimens were randomized to palmar fixation using a 2.4-mm variable-angle locking plate with either four or six distal screws. After embedding, constructs were subjected to cyclic axial loading (150 N, 5,000 cycles) simulating early postoperative rehabilitation. Global axial deformation and fragment-specific three-dimensional interfragmentary motion were recorded using an optical motion-tracking system. Statistical analysis was performed using non-parametric tests (p < 0.05).

Results

Two specimens from one donor pair were excluded, leaving 16 radii (8 pairs) for analysis. Bone mineral density and initial construct stiffness did not differ between groups. The six-screw configuration showed significantly lower axial deformation after cyclic loading (p = 0.047) and lower radial fragment–shaft translation at both time points (p = 0.028; p = 0.045). Radial fragment–shaft rotation was lower in the six-screw group at baseline (p = 0.018), but no rotational difference remained after cyclic loading. In the overall cohort, axial deformation decreased after cyclic loading (p = 0.015).

Conclusion

In this unstable intra-articular fracture model with radiodorsal metaphyseal comminution, six distal screws reduced post-cyclic axial deformation and radial fragment–shaft micromotion compared with four screws. The clinical relevance of these findings remains to be determined.

远端螺钉数目对AO/OTA 2R3 C2.1桡骨远端骨折轴向变形和碎片特异性稳定性的影响。
目的:探讨远端螺钉数对桡侧干骺端粉碎不稳定桡骨远端关节内骨折掌板固定的生物力学影响。方法:采用标准AO/OTA 2R3 C2.1骨折模型,确定桡侧干骺端缺损区,制备9对匹配的冷冻保存桡骨。对于每一对,标本随机使用2.4 mm可变角度锁定钢板与4或6个远端螺钉进行掌侧固定。埋置后,构建体接受循环轴向载荷(150 N, 5000循环)模拟术后早期康复。使用光学运动跟踪系统记录了整体轴向变形和碎片特定的三维碎片间运动。采用非参数检验进行统计分析(p)结果:排除一对供体的两个标本,留下16个半径(8对)进行分析。各组间骨密度和初始构造刚度无差异。在两个时间点,六螺杆结构在循环加载后的轴向变形(p = 0.047)和径向碎片-轴平移(p = 0.028; p = 0.045)均显著降低。在基线时,六螺钉组的径向碎片轴旋转较低(p = 0.018),但循环加载后旋转无差异。在整个队列中,循环加载后轴向变形减少(p = 0.015)。结论:在桡侧干骺端粉碎的不稳定关节内骨折模型中,与4枚螺钉相比,6枚远端螺钉减少了循环后轴向变形和桡骨碎片轴微动。这些发现的临床意义仍有待确定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.30
自引率
13.00%
发文量
424
审稿时长
2 months
期刊介绍: "Archives of Orthopaedic and Trauma Surgery" is a rich source of instruction and information for physicians in clinical practice and research in the extensive field of orthopaedics and traumatology. The journal publishes papers that deal with diseases and injuries of the musculoskeletal system from all fields and aspects of medicine. The journal is particularly interested in papers that satisfy the information needs of orthopaedic clinicians and practitioners. The journal places special emphasis on clinical relevance. "Archives of Orthopaedic and Trauma Surgery" is the official journal of the German Speaking Arthroscopy Association (AGA).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书