Effect of fiber post materials and timing of coronal preparation on sealing ability of post-core systems: A factorial design study.

IF 1.1 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
American journal of dentistry Pub Date : 2026-08-01
Chen Qu, Xiangling Liao
{"title":"Effect of fiber post materials and timing of coronal preparation on sealing ability of post-core systems: A factorial design study.","authors":"Chen Qu, Xiangling Liao","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To examine the effects of fiber post material and coronal preparation timing on the sealing ability of post-core systems and to determine whether these factors interact under thermal and mechanical aging conditions.</p><p><strong>Methods: </strong>A 2×2 factorial design was used. 60 freshly extracted single-rooted premolars meeting predefined inclusion and exclusion criteria were randomly assigned to four groups (n= 15): fiber-reinforced composite (FRC) post with immediate preparation, FRC with delayed preparation, prefabricated quartz fiber (PQF) post with immediate preparation, and PQF with delayed preparation. Post space length was standardized to 10 mm while maintaining a 4 mm apical seal, in accordance with the recommendation that post length should approximate two-thirds of root length and at least equal the clinical crown height. All procedures were completed by a single prosthodontist. Specimens underwent 5,000 thermal cycles followed by 240,000 cyclic loading cycles. Interfacial microgap width was serially evaluated by SEM at two time points, namely after thermocycling and after cyclic loading, and the data were analyzed with a linear mixed-effects model.</p><p><strong>Results: </strong>Post material type (F= 45.32, P< 0.001, η²p= 0.43) and time point (F= 312.56, P< 0.001, η²P= 0.84) showed significant effects, as did the material x time interaction (F= 8.73, P=0.004, η²P= 0.13). Preparation timing was not significant (F= 2.15, P= 0.148). After thermocycling, group B showed smaller microgap width than group D (3.91± 0.87 vs. 5.62± 1.77 µm; mean difference, -1.71 µm; 95%CI: -2.76 to -0.66; P=0.003). After cyclic loading, Group A was smaller than Group C (13.97± 1.89 vs. 17.85± 2.83 µm; mean difference, -3.88 µm; 95%CI: -5.62 to -2.14; P< 0.001), and Group B was smaller than group D (8.84± 1.98 vs. 13.29± 2.85 µm; mean difference, -4.45 µm; 95%CI: -6.22 to -2.68; P< 0.001). No root fractures were detected during specimen preparation, thermocycling, or cyclic loading.</p><p><strong>Clinical significance: </strong>For a given fiber post material, immediate and delayed coronal preparation produced comparable marginal sealing. Compared with prefabricated quartz fiber posts, fiber-reinforced composite post-core systems provided superior interfacial stability after aging and may be preferable in roots with irregular or flattened canal morphology.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"39 4","pages":"166-172"},"PeriodicalIF":1.1000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of dentistry","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To examine the effects of fiber post material and coronal preparation timing on the sealing ability of post-core systems and to determine whether these factors interact under thermal and mechanical aging conditions.

Methods: A 2×2 factorial design was used. 60 freshly extracted single-rooted premolars meeting predefined inclusion and exclusion criteria were randomly assigned to four groups (n= 15): fiber-reinforced composite (FRC) post with immediate preparation, FRC with delayed preparation, prefabricated quartz fiber (PQF) post with immediate preparation, and PQF with delayed preparation. Post space length was standardized to 10 mm while maintaining a 4 mm apical seal, in accordance with the recommendation that post length should approximate two-thirds of root length and at least equal the clinical crown height. All procedures were completed by a single prosthodontist. Specimens underwent 5,000 thermal cycles followed by 240,000 cyclic loading cycles. Interfacial microgap width was serially evaluated by SEM at two time points, namely after thermocycling and after cyclic loading, and the data were analyzed with a linear mixed-effects model.

Results: Post material type (F= 45.32, P< 0.001, η²p= 0.43) and time point (F= 312.56, P< 0.001, η²P= 0.84) showed significant effects, as did the material x time interaction (F= 8.73, P=0.004, η²P= 0.13). Preparation timing was not significant (F= 2.15, P= 0.148). After thermocycling, group B showed smaller microgap width than group D (3.91± 0.87 vs. 5.62± 1.77 µm; mean difference, -1.71 µm; 95%CI: -2.76 to -0.66; P=0.003). After cyclic loading, Group A was smaller than Group C (13.97± 1.89 vs. 17.85± 2.83 µm; mean difference, -3.88 µm; 95%CI: -5.62 to -2.14; P< 0.001), and Group B was smaller than group D (8.84± 1.98 vs. 13.29± 2.85 µm; mean difference, -4.45 µm; 95%CI: -6.22 to -2.68; P< 0.001). No root fractures were detected during specimen preparation, thermocycling, or cyclic loading.

Clinical significance: For a given fiber post material, immediate and delayed coronal preparation produced comparable marginal sealing. Compared with prefabricated quartz fiber posts, fiber-reinforced composite post-core systems provided superior interfacial stability after aging and may be preferable in roots with irregular or flattened canal morphology.

纤维桩材料和冠状制备时间对桩核系统密封能力的影响:一项析因设计研究。
目的:研究纤维桩材料和冠状制备时间对桩核系统密封能力的影响,并确定这些因素在热老化和机械老化条件下是否相互作用。方法:采用2×2因子设计。将60颗符合纳入和排除标准的新鲜拔牙单根前磨牙随机分为4组(n= 15):纤维增强复合材料(FRC)即刻预备组、FRC延迟预备组、预制石英纤维(PQF)即刻预备组和PQF延迟预备组。柱空间长度标准化为10毫米,同时保持4毫米的根尖密封,按照推荐的柱长度应该接近根长度的三分之二,至少等于临床冠高度。所有程序均由一名义齿医师完成。试样经历了5000次热循环和24万次循环加载。采用SEM对热循环后和循环加载后两个时间点的界面微间隙宽度进行了连续评价,并采用线性混合效应模型对数据进行了分析。结果:后材料类型(F= 45.32, P< 0.001, η²P= 0.43)、时间点(F= 312.56, P< 0.001, η²P= 0.84)和材料与时间的相互作用(F= 8.73, P=0.004, η²P= 0.13)均有显著影响。制备时间差异无统计学意义(F= 2.15, P= 0.148)。热循环后,B组微隙宽度小于D组(3.91±0.87∶5.62±1.77µm;平均差值为-1.71µm; 95%CI: -2.76 ~ -0.66; P=0.003)。循环加载后,A组小于C组(13.97±1.89比17.85±2.83µm,平均差值-3.88µm, 95%CI: -5.62 ~ -2.14, P< 0.001), B组小于D组(8.84±1.98比13.29±2.85µm,平均差值-4.45µm, 95%CI: -6.22 ~ -2.68, P< 0.001)。在标本制备、热循环或循环加载过程中未检测到根断裂。临床意义:对于给定的纤维桩材料,立即和延迟冠状冠预备产生相当的边缘密封。与预制石英纤维桩相比,纤维增强复合桩核系统在老化后具有更好的界面稳定性,并且更适合于不规则或扁平根管形态的根。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
American journal of dentistry
American journal of dentistry 医学-牙科与口腔外科
CiteScore
2.40
自引率
7.10%
发文量
57
审稿时长
1 months
期刊介绍: The American Journal of Dentistry, published by Mosher & Linder, Inc., provides peer-reviewed scientific articles with clinical significance for the general dental practitioner.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书