Radiologic and clinical outcomes of a novel scapular anatomical plate for glenoid articular and periarticular fractures.

IF 1.6 4区 医学
Journal of Orthopaedic Surgery Pub Date : 2026-05-01 Epub Date: 2026-08-08 DOI:10.1177/10225536261478326
Doo-Hyung Lee, Myung-Sub Lee, Won-Tae Cho, Seungyeob Sakong, Sumin Lim, Wan-Sun Choi
{"title":"Radiologic and clinical outcomes of a novel scapular anatomical plate for glenoid articular and periarticular fractures.","authors":"Doo-Hyung Lee, Myung-Sub Lee, Won-Tae Cho, Seungyeob Sakong, Sumin Lim, Wan-Sun Choi","doi":"10.1177/10225536261478326","DOIUrl":null,"url":null,"abstract":"<p><p>PurposeTo evaluate the radiologic and clinical outcomes of a novel scapular anatomical plate designed for fixation of glenoid articular and periarticular fractures.MethodsThis prospective case series included 14 patients with scapular fractures treated between 2020 and 2024. Indications for surgery were intra-articular step-off >3 mm, glenoid medialization >20 mm, or glenoid angulation >30°. All patients underwent open reduction and internal fixation using the newly developed anatomical plate and were followed for at least 12 months. Radiologic outcomes were assessed using computed tomography, including intra-articular step-off, lateral border offset, and glenoid angular deformity. Clinical outcomes were evaluated using shoulder range of motion, Disabilities of the Arm, Shoulder and Hand (DASH) score, modified American Shoulder and Elbow Surgeons (ASES) score, and visual analog scale (VAS) for pain.ResultsSix patients had intra-articular fractures and eight had extra-articular fractures. Mean intra-articular step-off improved from 6.3 mm to 1.9 mm, lateral border offset from 21.2 mm to 2.3 mm, and glenoid angular deformity from 30.1° to near-anatomical alignment postoperatively. No articular screw penetration was observed on postoperative CT. All fractures achieved radiographic union without loss of reduction or implant-related complications. At 12 months, mean forward flexion was 136.4°, DASH score 24.5, modified ASES score 72.9, and VAS score 3.1.ConclusionThe novel scapular anatomical plate provided stable fixation with satisfactory radiologic restoration and favorable clinical outcomes for glenoid articular and periarticular fractures.</p>","PeriodicalId":16608,"journal":{"name":"Journal of Orthopaedic Surgery","volume":"34 2","pages":"10225536261478326"},"PeriodicalIF":1.6000,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/10225536261478326","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/8 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

PurposeTo evaluate the radiologic and clinical outcomes of a novel scapular anatomical plate designed for fixation of glenoid articular and periarticular fractures.MethodsThis prospective case series included 14 patients with scapular fractures treated between 2020 and 2024. Indications for surgery were intra-articular step-off >3 mm, glenoid medialization >20 mm, or glenoid angulation >30°. All patients underwent open reduction and internal fixation using the newly developed anatomical plate and were followed for at least 12 months. Radiologic outcomes were assessed using computed tomography, including intra-articular step-off, lateral border offset, and glenoid angular deformity. Clinical outcomes were evaluated using shoulder range of motion, Disabilities of the Arm, Shoulder and Hand (DASH) score, modified American Shoulder and Elbow Surgeons (ASES) score, and visual analog scale (VAS) for pain.ResultsSix patients had intra-articular fractures and eight had extra-articular fractures. Mean intra-articular step-off improved from 6.3 mm to 1.9 mm, lateral border offset from 21.2 mm to 2.3 mm, and glenoid angular deformity from 30.1° to near-anatomical alignment postoperatively. No articular screw penetration was observed on postoperative CT. All fractures achieved radiographic union without loss of reduction or implant-related complications. At 12 months, mean forward flexion was 136.4°, DASH score 24.5, modified ASES score 72.9, and VAS score 3.1.ConclusionThe novel scapular anatomical plate provided stable fixation with satisfactory radiologic restoration and favorable clinical outcomes for glenoid articular and periarticular fractures.

新型肩胛骨解剖钢板治疗关节盂和关节周围骨折的放射学和临床效果。
目的探讨一种新型肩胛骨解剖钢板固定关节盂及关节周骨折的放射学和临床效果。方法本前瞻性病例系列包括14例于2020年至2024年间接受治疗的肩胛骨骨折患者。手术指征为关节内步离bbb30 mm,关节盂内侧化>20 mm,或关节盂成角>30°。所有患者均采用新开发的解剖钢板进行切开复位和内固定,随访至少12个月。使用计算机断层扫描评估放射学结果,包括关节内台阶偏移、外侧边界偏移和关节关节角畸形。临床结果采用肩关节活动度、手臂、肩膀和手的残疾(DASH)评分、改良的美国肩肘外科医生(ASES)评分和疼痛的视觉模拟量表(VAS)来评估。结果关节内骨折6例,关节外骨折8例。平均关节内步距从6.3 mm改善到1.9 mm,外侧边界偏移从21.2 mm改善到2.3 mm,术后关节关节角畸形从30.1°改善到接近解剖对准。术后CT未见关节螺钉穿透。所有骨折均达到x线愈合,无复位丢失或植入物相关并发症。12个月时,患者平均前屈136.4°,DASH评分24.5,改良as评分72.9,VAS评分3.1。结论新型肩胛骨解剖钢板对关节盂及关节周骨折的固定稳定,放射学恢复满意,临床效果良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
91
期刊介绍: Journal of Orthopaedic Surgery is an open access peer-reviewed journal publishing original reviews and research articles on all aspects of orthopaedic surgery. It is the official journal of the Asia Pacific Orthopaedic Association. The journal welcomes and will publish materials of a diverse nature, from basic science research to clinical trials and surgical techniques. The journal encourages contributions from all parts of the world, but special emphasis is given to research of particular relevance to the Asia Pacific region.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书