Jun Wang, Yong Cheng, Yewen Jiang, Zijun Zheng, Zhanglei Li, Zhen Wang, Shutian An, Jun Chen, Kevin J Glaser, Arvin Arani, Yongqiang Yu, Ren Zhao, Xiaohu Li, Md PhD
{"title":"Reproducibility of 3.0 T single-frequency cardiac MR elastography for quantification of left ventricular myocardial stiffness.","authors":"Jun Wang, Yong Cheng, Yewen Jiang, Zijun Zheng, Zhanglei Li, Zhen Wang, Shutian An, Jun Chen, Kevin J Glaser, Arvin Arani, Yongqiang Yu, Ren Zhao, Xiaohu Li, Md PhD","doi":"10.1093/radadv/umag032","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Cardiac magnetic resonance elastography (MRE) allows the non-invasive quantification of myocardial stiffness, but long-interval reproducibility data at 3.0 T single-frequency 140-Hz remain limited.</p><p><strong>Purpose: </strong>To evaluate the short- and long-interval reproducibility of 3.0 T cardiac MRE for left ventricular (LV) myocardial stiffness across healthy volunteers and patients with conditions associated with elevated myocardial stiffness.</p><p><strong>Materials and methods: </strong>This prospective single-center study included 69 participants: 60 healthy volunteers and 9 with cardiovascular disease (6 with aortic stenosis and 3 with long-standing hypertension). All participants underwent baseline cardiac MRE (scanner: Signa Premier 3.0 T, GE Healthcare, driver: Resoundant), an immediate short-interval rescan (SIR) within 5 minutes, and a long-interval rescan (LIR) after approximately 1 month. Left ventricular myocardial stiffness and octahedral shear strain signal-to-noise ratio were measured independently by 2 readers. Reproducibility was assessed using Bland-Altman analysis, intraclass correlation coefficients (ICCs), within-subject coefficient of variation, standard error of measurement, and smallest detectable change at the 95% confidence (SDC95) level.</p><p><strong>Results: </strong>Baseline LV myocardial stiffness was higher in the disease group than in healthy volunteers, 11.73 ± 1.01 kPa and 7.80 ± 0.70 kPa (mean ± SD; <i>P</i> < .001), respectively. Inter-reader agreement was excellent across all timepoints, with ICCs of 0.970 at baseline (95% CI, 0.953-0.982), 0.966 for SIR (95% CI, 0.945-0.979), and 0.962 for LIR (95% CI, 0.939-0.976). Within-reader scan-rescan reproducibility was also excellent. For Reader 1, stiffness ICC was 0.979 for the SIR (95% CI, 0.966-0.987) and 0.957 for the LIR (95% CI, 0.932-0.973), with SDC95 values of 0.616 kPa (95% CI, 0.528-0.741) and 0.869 kPa (95% CI, 0.744-1.044), respectively. Reader 2 showed excellent reproducibility, with ICCs ≤0.943.</p><p><strong>Conclusions: </strong>3D single-frequency 140-Hz cardiac MRE at 3.0 T provides excellent short- and long-interval reproducibility for LV myocardial stiffness quantification. The SDC95 values may help distinguish true longitudinal stiffness changes from measurement variability.</p>","PeriodicalId":519940,"journal":{"name":"Radiology advances","volume":"3 4","pages":"umag032"},"PeriodicalIF":1.8000,"publicationDate":"2026-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13447016/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiology advances","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/radadv/umag032","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Cardiac magnetic resonance elastography (MRE) allows the non-invasive quantification of myocardial stiffness, but long-interval reproducibility data at 3.0 T single-frequency 140-Hz remain limited.
Purpose: To evaluate the short- and long-interval reproducibility of 3.0 T cardiac MRE for left ventricular (LV) myocardial stiffness across healthy volunteers and patients with conditions associated with elevated myocardial stiffness.
Materials and methods: This prospective single-center study included 69 participants: 60 healthy volunteers and 9 with cardiovascular disease (6 with aortic stenosis and 3 with long-standing hypertension). All participants underwent baseline cardiac MRE (scanner: Signa Premier 3.0 T, GE Healthcare, driver: Resoundant), an immediate short-interval rescan (SIR) within 5 minutes, and a long-interval rescan (LIR) after approximately 1 month. Left ventricular myocardial stiffness and octahedral shear strain signal-to-noise ratio were measured independently by 2 readers. Reproducibility was assessed using Bland-Altman analysis, intraclass correlation coefficients (ICCs), within-subject coefficient of variation, standard error of measurement, and smallest detectable change at the 95% confidence (SDC95) level.
Results: Baseline LV myocardial stiffness was higher in the disease group than in healthy volunteers, 11.73 ± 1.01 kPa and 7.80 ± 0.70 kPa (mean ± SD; P < .001), respectively. Inter-reader agreement was excellent across all timepoints, with ICCs of 0.970 at baseline (95% CI, 0.953-0.982), 0.966 for SIR (95% CI, 0.945-0.979), and 0.962 for LIR (95% CI, 0.939-0.976). Within-reader scan-rescan reproducibility was also excellent. For Reader 1, stiffness ICC was 0.979 for the SIR (95% CI, 0.966-0.987) and 0.957 for the LIR (95% CI, 0.932-0.973), with SDC95 values of 0.616 kPa (95% CI, 0.528-0.741) and 0.869 kPa (95% CI, 0.744-1.044), respectively. Reader 2 showed excellent reproducibility, with ICCs ≤0.943.
Conclusions: 3D single-frequency 140-Hz cardiac MRE at 3.0 T provides excellent short- and long-interval reproducibility for LV myocardial stiffness quantification. The SDC95 values may help distinguish true longitudinal stiffness changes from measurement variability.