Let distortion-guided restoration: a physics-informed learning framework to correct prostate diffusion MRI artifacts.

IF 1.8
Radiology advances Pub Date : 2026-07-14 eCollection Date: 2026-07-01 DOI:10.1093/radadv/umag031
Ziyang Long, Nader Binesh, Lixia Wang, Archana Vadiraj Malaji, Chia-Chi Yang, Haoran Sun, Rola Saouaf, Timothy Daskivich, Hyung Kim, Yibin Xie, Debiao Li, Hsin-Jung Yang
{"title":"Let distortion-guided restoration: a physics-informed learning framework to correct prostate diffusion MRI artifacts.","authors":"Ziyang Long, Nader Binesh, Lixia Wang, Archana Vadiraj Malaji, Chia-Chi Yang, Haoran Sun, Rola Saouaf, Timothy Daskivich, Hyung Kim, Yibin Xie, Debiao Li, Hsin-Jung Yang","doi":"10.1093/radadv/umag031","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Susceptibility-induced distortion in single-shot echo-planar imaging (ssEPI) prostate diffusion-weighted imaging (DWI) can degrade lesion conspicuity, apparent diffusion coefficient (ADC) estimation, and confidence in prostate MRI interpretation. Conventional correction strategies typically require additional acquisitions and may be limited in severe artifact settings.</p><p><strong>Purpose: </strong>To develop a physics-informed deep learning framework, distortion-guided restoration (DGR), for acquisition-free correction of ssEPI distortions in prostate DWI.</p><p><strong>Materials and methods: </strong>Distortion-guided restoration was proposed to learn the inverse of a physically simulated ssEPI distortion process. Clinical prostate DWI and T<sub>2</sub>-weighted (T<sub>2</sub>W) images from 408 3T MR examinations originating from 2 clinical datasets, acquired on Siemens 3T MAGNETOM Vida and Biograph mMR scanners, were used for paired distorted/undistorted training data across low-b DWI (<i>b</i> = 50 s/mm<sup>2</sup>), and scanner-provided ADC maps. The restoration network integrates a convolutional neural network (CNN)-based geometric correction module with a conditional diffusion refinement module, both guided by co-registered T<sub>2</sub>W images. Model selection and benchmarking were performed on a held-out synthetic test set (<i>n</i> = 34), against conventional algorithms using correction field mapping (FSL FUGUE and TOPUP). Model performance was evaluated in a retrospective study on 34 clinical scans with severe susceptibility artifacts drawn from the same clinical datasets, using quantitative image metrics and blinded radiologist scoring.</p><p><strong>Results: </strong>On synthetic data, the proposed DGR model achieved the highest peak signal-to-noise ratio (PSNR) and lowest normalized mean squared error (NMSE) across low-b DWI (0.089; 95% CI, 0.072-0.105) and ADC maps (0.062; 95% CI, 0.053-0.072), outperforming FSL TOPUP and FUGUE (all <i>P</i> < .001). In the 34 clinical cases affected by susceptibility artifacts, including 16 cases with histologically confirmed lesions (16/34, 47.1%), DGR substantially improved geometric fidelity (2.74 to 3.29), identified all histologically confirmed lesions (16/16, 100%), and enhanced overall image quality and diagnostic confidence (all <i>P</i> < .001).</p><p><strong>Conclusion: </strong>This proof-of-concept study suggests that a physics-informed hybrid CNN-diffusion framework offers a practical and acquisition-free solution for correcting severe prostate DWI distortions. It warrants further development for clinical utility and implementation.</p>","PeriodicalId":519940,"journal":{"name":"Radiology advances","volume":"3 4","pages":"umag031"},"PeriodicalIF":1.8000,"publicationDate":"2026-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13446218/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiology advances","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/radadv/umag031","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Susceptibility-induced distortion in single-shot echo-planar imaging (ssEPI) prostate diffusion-weighted imaging (DWI) can degrade lesion conspicuity, apparent diffusion coefficient (ADC) estimation, and confidence in prostate MRI interpretation. Conventional correction strategies typically require additional acquisitions and may be limited in severe artifact settings.

Purpose: To develop a physics-informed deep learning framework, distortion-guided restoration (DGR), for acquisition-free correction of ssEPI distortions in prostate DWI.

Materials and methods: Distortion-guided restoration was proposed to learn the inverse of a physically simulated ssEPI distortion process. Clinical prostate DWI and T2-weighted (T2W) images from 408 3T MR examinations originating from 2 clinical datasets, acquired on Siemens 3T MAGNETOM Vida and Biograph mMR scanners, were used for paired distorted/undistorted training data across low-b DWI (b = 50 s/mm2), and scanner-provided ADC maps. The restoration network integrates a convolutional neural network (CNN)-based geometric correction module with a conditional diffusion refinement module, both guided by co-registered T2W images. Model selection and benchmarking were performed on a held-out synthetic test set (n = 34), against conventional algorithms using correction field mapping (FSL FUGUE and TOPUP). Model performance was evaluated in a retrospective study on 34 clinical scans with severe susceptibility artifacts drawn from the same clinical datasets, using quantitative image metrics and blinded radiologist scoring.

Results: On synthetic data, the proposed DGR model achieved the highest peak signal-to-noise ratio (PSNR) and lowest normalized mean squared error (NMSE) across low-b DWI (0.089; 95% CI, 0.072-0.105) and ADC maps (0.062; 95% CI, 0.053-0.072), outperforming FSL TOPUP and FUGUE (all P < .001). In the 34 clinical cases affected by susceptibility artifacts, including 16 cases with histologically confirmed lesions (16/34, 47.1%), DGR substantially improved geometric fidelity (2.74 to 3.29), identified all histologically confirmed lesions (16/16, 100%), and enhanced overall image quality and diagnostic confidence (all P < .001).

Conclusion: This proof-of-concept study suggests that a physics-informed hybrid CNN-diffusion framework offers a practical and acquisition-free solution for correcting severe prostate DWI distortions. It warrants further development for clinical utility and implementation.

让扭曲引导修复:一个物理知识的学习框架,以纠正前列腺弥散MRI伪影。
背景:单次回波平面成像(ssEPI)前列腺弥散加权成像(DWI)的敏感性畸变会降低病变的显著性、表观弥散系数(ADC)估计和前列腺MRI解释的可信度。传统的校正策略通常需要额外的获取,并且在严重的工件设置中可能受到限制。目的:开发一个物理信息深度学习框架,扭曲引导恢复(DGR),用于前列腺DWI中ssEPI扭曲的无获取校正。材料和方法:提出了扭曲引导修复来学习物理模拟ssEPI扭曲过程的逆过程。临床前列腺DWI和t2加权(T2W)图像来自2个临床数据集,来自西门子3T MAGNETOM Vida和Biograph mMR扫描仪获取的408张3T MR检查图像,用于配对扭曲/未扭曲的低b DWI (b = 50 s/mm2)和扫描仪提供的ADC图的训练数据。该恢复网络集成了基于卷积神经网络(CNN)的几何校正模块和条件扩散细化模块,均以共配准T2W图像为指导。在一个固定的合成测试集(n = 34)上进行模型选择和基准测试,对比使用校正场映射(FSL FUGUE和TOPUP)的传统算法。模型的性能在一项回顾性研究中进行评估,该研究对来自相同临床数据集的34次临床扫描进行了严重的敏感性伪影,使用定量图像指标和盲法放射科医生评分。结果:在合成数据上,提出的DGR模型在低b DWI (0.089; 95% CI, 0.072-0.105)和ADC图(0.062;95% CI, 0.053-0.072)上实现了最高的峰值信噪比(PSNR)和最低的归一化均方差(NMSE),优于FSL TOPUP和FUGUE(所有P P)结论:这一概念验证研究表明,物理信息混合cnn -扩散框架为纠正严重的前列腺DWI失真提供了一种实用且无获取的解决方案。它值得进一步发展临床应用和实施。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书