Feasibility and usability of a wearable sensor-based telerehabilitation program for home-based exercise in patients with lower limb amputation: a pilot study.
Ravi Shankar, Pei Shan Tong, Emily Yee, Poo Lee Ong
{"title":"Feasibility and usability of a wearable sensor-based telerehabilitation program for home-based exercise in patients with lower limb amputation: a pilot study.","authors":"Ravi Shankar, Pei Shan Tong, Emily Yee, Poo Lee Ong","doi":"10.3389/fresc.2026.1828171","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Lower limb amputation (LLA) presents significant rehabilitation challenges, with patients requiring comprehensive multidisciplinary care to achieve optimal functional outcomes. Telerehabilitation using wearable sensor technology offers a promising solution to improve therapy accessibility and exercise adherence among this population. This pilot study evaluated the feasibility, usability, and preliminary effects on hip strength, and user acceptability of a home-based telerehabilitation program using the Rebee wearable sensor system for patients with major lower extremity amputation.</p><p><strong>Methods: </strong>A prospective single-arm feasibility study was conducted at the Foot Care and Limb Design Centre, Tan Tock Seng Hospital, Singapore. Ten participants with unilateral major amputations (5 transtibial, 5 transfemoral) were enrolled. Participants performed daily home exercises using the Rebee inertial measurement unit (IMU) sensor system for 30 days, with remote monitoring and biweekly adjustments. Primary outcomes included hip extensor and abductor strength assessed using dynamometry at baseline (Week 0), Week 4, and Week 8. Secondary outcomes included quality of life (EQ-5D-5L), exercise compliance, patient satisfaction, and system usability (System Usability Scale).</p><p><strong>Results: </strong>All ten participants (80% male; median age 51.5 years, IQR 11) completed the intervention. Median hip extensor strength improved significantly from 8.43 kg at baseline to 9.87 kg at Week 4 (<i>p</i> < 0.05) and 10.88 kg at Week 8 (<i>p</i> < 0.05). Median hip abductor strength increased from 8.01 to 9.45 kg (Week 4) and 9.70 kg (Week 8), with statistically significant improvements (<i>p</i> < 0.05). Mean exercise compliance was 68%. The mean System Usability Scale score was 75.8, indicating favorable usability. Health-related quality of life showed mixed patterns: median self-rated health (EQ-VAS) increased from 80 at baseline to 87.5 by Week 8, whereas the proportion of participants reporting problems in several EQ-5D-5L dimensions did not improve and slightly increased. No adverse events were reported.</p><p><strong>Conclusions: </strong>Home-based telerehabilitation using the Rebee wearable sensor system is feasible, safe, and acceptable for patients with lower limb amputation, with preliminary improvements in hip strength. High user satisfaction and favorable usability support its potential. However, as a single-arm pilot without a control group, findings remain preliminary and not generalizable. Future RCTs are needed to confirm effectiveness and cost-effectiveness for clinical integration.</p>","PeriodicalId":73102,"journal":{"name":"Frontiers in rehabilitation sciences","volume":"7 ","pages":"1828171"},"PeriodicalIF":2.5000,"publicationDate":"2026-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13442527/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in rehabilitation sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fresc.2026.1828171","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Lower limb amputation (LLA) presents significant rehabilitation challenges, with patients requiring comprehensive multidisciplinary care to achieve optimal functional outcomes. Telerehabilitation using wearable sensor technology offers a promising solution to improve therapy accessibility and exercise adherence among this population. This pilot study evaluated the feasibility, usability, and preliminary effects on hip strength, and user acceptability of a home-based telerehabilitation program using the Rebee wearable sensor system for patients with major lower extremity amputation.
Methods: A prospective single-arm feasibility study was conducted at the Foot Care and Limb Design Centre, Tan Tock Seng Hospital, Singapore. Ten participants with unilateral major amputations (5 transtibial, 5 transfemoral) were enrolled. Participants performed daily home exercises using the Rebee inertial measurement unit (IMU) sensor system for 30 days, with remote monitoring and biweekly adjustments. Primary outcomes included hip extensor and abductor strength assessed using dynamometry at baseline (Week 0), Week 4, and Week 8. Secondary outcomes included quality of life (EQ-5D-5L), exercise compliance, patient satisfaction, and system usability (System Usability Scale).
Results: All ten participants (80% male; median age 51.5 years, IQR 11) completed the intervention. Median hip extensor strength improved significantly from 8.43 kg at baseline to 9.87 kg at Week 4 (p < 0.05) and 10.88 kg at Week 8 (p < 0.05). Median hip abductor strength increased from 8.01 to 9.45 kg (Week 4) and 9.70 kg (Week 8), with statistically significant improvements (p < 0.05). Mean exercise compliance was 68%. The mean System Usability Scale score was 75.8, indicating favorable usability. Health-related quality of life showed mixed patterns: median self-rated health (EQ-VAS) increased from 80 at baseline to 87.5 by Week 8, whereas the proportion of participants reporting problems in several EQ-5D-5L dimensions did not improve and slightly increased. No adverse events were reported.
Conclusions: Home-based telerehabilitation using the Rebee wearable sensor system is feasible, safe, and acceptable for patients with lower limb amputation, with preliminary improvements in hip strength. High user satisfaction and favorable usability support its potential. However, as a single-arm pilot without a control group, findings remain preliminary and not generalizable. Future RCTs are needed to confirm effectiveness and cost-effectiveness for clinical integration.
背景:下肢截肢(LLA)带来了重大的康复挑战,患者需要全面的多学科护理才能达到最佳的功能结局。远程康复使用可穿戴传感器技术提供了一个有前途的解决方案,以提高治疗的可及性和锻炼依从性的人群。本初步研究评估了Rebee可穿戴传感器系统用于下肢主要截肢患者的家庭远程康复方案的可行性、可用性、对髋关节力量的初步影响以及用户可接受性。方法:在新加坡Tan Tock Seng医院足部护理和肢体设计中心进行了一项前瞻性单臂可行性研究。入选10例单侧大截肢患者(5例经胫骨,5例经股骨)。参与者每天使用Rebee惯性测量单元(IMU)传感器系统进行30天的家庭锻炼,并进行远程监测和每两周调整一次。主要结果包括在基线(第0周)、第4周和第8周使用动力测量法评估髋伸肌和外展肌力量。次要结局包括生活质量(EQ-5D-5L)、运动依从性、患者满意度和系统可用性(系统可用性量表)。结果:所有10名参与者(80%为男性,中位年龄51.5岁,IQR 11)均完成了干预。中位髋关节伸肌力量从基线时的8.43 kg显著提高到第4周时的9.87 kg (p p p)。结论:对于下肢截肢患者,使用Rebee可穿戴传感器系统进行家庭远程康复是可行、安全且可接受的,髋关节力量有初步改善。高用户满意度和良好的可用性支持其潜力。然而,作为一个没有对照组的单臂飞行员,研究结果仍然是初步的,不能推广。需要未来的随机对照试验来确认临床整合的有效性和成本效益。