{"title":"Internal feasibility evaluation of SAM-Med3D for cervical cancer clinical target volume segmentation on planning computed tomography.","authors":"Bo-Ying Li, Ting Fan, Jia-Yan Chen, Yu-Hui Zhang","doi":"10.1007/s12194-026-01092-4","DOIUrl":null,"url":null,"abstract":"<p><p>Accurate delineation of cervical cancer clinical target volume (CTV) remains labor-intensive and variable. This retrospective single-center study internally evaluated a SAM-Med3D baseline initialized from public pretrained weights and fine-tuned on the study training cohort for prompted cervical cancer CTV segmentation on planning CT. The eligible cohort comprised 182 cases split into training ([Formula: see text]), validation ([Formula: see text]), and temporally subsequent independent test ([Formula: see text]) sets. CT scans were resampled, normalized, and prepared as label-centered 128 × 128 × 128 patches. The SAM-Med3D model was initialized from public pretrained weights and fine-tuned on the training cohort without architectural modification, then assessed with simulated/oracle-guided prompts at 1, 3, 5, 7, 9, and 11 clicks using Dice, HD95, 3-mm surface Dice, and volume consistency. Mean Dice increased from 0.827 at 1 click to a peak of 0.835 at 7 clicks and was 0.833 at 11 clicks. HD95 decreased from 12.46 mm at 1 click to 9.48 mm at 9 clicks and 10.18 mm at 11 clicks, and 3-mm surface Dice increased from 0.707 to 0.721 at 7 clicks. Thus, multi-click prompting produced modest improvements that plateaued at later clicks. A supplementary risk-guided prompt-selection pilot was performed on the same test set but was treated only as exploratory. Because patch extraction and prompt generation used reference-contour information, all analyses represent controlled upper-bound evidence. This study provides an internal feasibility baseline for promptable cervical cancer CTV segmentation; label-free ROI selection, full-volume inference, external validation, and clinician-in-the-loop testing remain necessary before clinical deployment.</p>","PeriodicalId":46252,"journal":{"name":"Radiological Physics and Technology","volume":" ","pages":"1168-1178"},"PeriodicalIF":1.6000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiological Physics and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12194-026-01092-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/7 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Accurate delineation of cervical cancer clinical target volume (CTV) remains labor-intensive and variable. This retrospective single-center study internally evaluated a SAM-Med3D baseline initialized from public pretrained weights and fine-tuned on the study training cohort for prompted cervical cancer CTV segmentation on planning CT. The eligible cohort comprised 182 cases split into training ([Formula: see text]), validation ([Formula: see text]), and temporally subsequent independent test ([Formula: see text]) sets. CT scans were resampled, normalized, and prepared as label-centered 128 × 128 × 128 patches. The SAM-Med3D model was initialized from public pretrained weights and fine-tuned on the training cohort without architectural modification, then assessed with simulated/oracle-guided prompts at 1, 3, 5, 7, 9, and 11 clicks using Dice, HD95, 3-mm surface Dice, and volume consistency. Mean Dice increased from 0.827 at 1 click to a peak of 0.835 at 7 clicks and was 0.833 at 11 clicks. HD95 decreased from 12.46 mm at 1 click to 9.48 mm at 9 clicks and 10.18 mm at 11 clicks, and 3-mm surface Dice increased from 0.707 to 0.721 at 7 clicks. Thus, multi-click prompting produced modest improvements that plateaued at later clicks. A supplementary risk-guided prompt-selection pilot was performed on the same test set but was treated only as exploratory. Because patch extraction and prompt generation used reference-contour information, all analyses represent controlled upper-bound evidence. This study provides an internal feasibility baseline for promptable cervical cancer CTV segmentation; label-free ROI selection, full-volume inference, external validation, and clinician-in-the-loop testing remain necessary before clinical deployment.
期刊介绍:
The purpose of the journal Radiological Physics and Technology is to provide a forum for sharing new knowledge related to research and development in radiological science and technology, including medical physics and radiological technology in diagnostic radiology, nuclear medicine, and radiation therapy among many other radiological disciplines, as well as to contribute to progress and improvement in medical practice and patient health care.