Simultaneously quantifyingK1,k2, and blood volume in myocardial imaging with overlapping volumes of interest: structural identifiability.

IF 3.1 3区 医学 Q2 ENGINEERING, BIOMEDICAL
Scott D Metzler, Dale J Stentz, Marie A Guerraty
{"title":"Simultaneously quantifyingK1,k2, and blood volume in myocardial imaging with overlapping volumes of interest: structural identifiability.","authors":"Scott D Metzler, Dale J Stentz, Marie A Guerraty","doi":"10.1088/1361-6560/ae968a","DOIUrl":null,"url":null,"abstract":"<p><p>Dynamic imaging in emission computed tomography allows the determination of physiological parameters that have important clinical implications. In myocardial imaging, three parameters of interest are the uptake and washout rates,and, respectively, and the blood-volume fraction,. These parameters can be determined from time-activity curves (TACs) of the blood (i.e. the input function) and the myocardium. However, the volumes of interest for the dynamic images may show overlap of these regions; this overlap can be expressed as a mixing matrix. Herein, we address the requirements for mathematical uniqueness of the solutions. The relationship of the TACs of the myocardium and blood pool with model parameters is evaluated under the structural identifiability criterion, which requires equal observed TACs to have a one-to-one mapping with the model parameters. This leads to constraints on the model parameters. Those constraints lead to system invariants, specifying the relationship between the true solution of the equations and other candidate solutions consistent with the observations for the TACs. Structural identifiability is achieved for,, andif all parameters of the mixing matrix are known. These results provide a complete structural identifiability analysis for a one-tissue compartment model with a mixing matrix that accounts for partial-volume effects and spill-in/out of volumes of interest. Prior results showed a more relaxed condition whenwas assumed to be zero.</p>","PeriodicalId":20185,"journal":{"name":"Physics in medicine and biology","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2026-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics in medicine and biology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6560/ae968a","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Dynamic imaging in emission computed tomography allows the determination of physiological parameters that have important clinical implications. In myocardial imaging, three parameters of interest are the uptake and washout rates,and, respectively, and the blood-volume fraction,. These parameters can be determined from time-activity curves (TACs) of the blood (i.e. the input function) and the myocardium. However, the volumes of interest for the dynamic images may show overlap of these regions; this overlap can be expressed as a mixing matrix. Herein, we address the requirements for mathematical uniqueness of the solutions. The relationship of the TACs of the myocardium and blood pool with model parameters is evaluated under the structural identifiability criterion, which requires equal observed TACs to have a one-to-one mapping with the model parameters. This leads to constraints on the model parameters. Those constraints lead to system invariants, specifying the relationship between the true solution of the equations and other candidate solutions consistent with the observations for the TACs. Structural identifiability is achieved for,, andif all parameters of the mixing matrix are known. These results provide a complete structural identifiability analysis for a one-tissue compartment model with a mixing matrix that accounts for partial-volume effects and spill-in/out of volumes of interest. Prior results showed a more relaxed condition whenwas assumed to be zero.

同时定量k1,k2和心肌成像血容量与重叠感兴趣的体积:结构可识别性。
发射计算机断层扫描中的动态成像可以确定具有重要临床意义的生理参数。在心肌成像中,三个感兴趣的参数分别是摄取率和冲洗率K1和k2,以及血容量分数v。这些参数可以从血液(即输入功能)和心肌的时间-活性曲线(TACs)中确定。然而,动态 ;图像感兴趣的体积可能显示这些区域的重叠;这种重叠可以表示为混合矩阵。在这里,我们解决了 ;解的数学唯一性要求。根据结构可识别性标准评价心肌及血池TACs与模型参数的关系,即要求观察到的相等TACs与模型参数一一对应。这导致了对模型参数的约束。这些约束导致了系统不变量,指定了方程的真解与与tac的观测结果一致的其他候选解之间的关系。如果混合矩阵的所有参数 ;已知,则K1、k2和V的结构 ;可识别。这些结果为具有混合矩阵的单组织室模型提供了完整的结构可识别性分析,该模型考虑了部分体积 效应和VOI的溢出。先前的结果表明,假设k2 ;为零时,情况更为宽松。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Physics in medicine and biology
Physics in medicine and biology 医学-工程:生物医学
CiteScore
6.50
自引率
14.30%
发文量
409
审稿时长
2 months
期刊介绍: The development and application of theoretical, computational and experimental physics to medicine, physiology and biology. Topics covered are: therapy physics (including ionizing and non-ionizing radiation); biomedical imaging (e.g. x-ray, magnetic resonance, ultrasound, optical and nuclear imaging); image-guided interventions; image reconstruction and analysis (including kinetic modelling); artificial intelligence in biomedical physics and analysis; nanoparticles in imaging and therapy; radiobiology; radiation protection and patient dose monitoring; radiation dosimetry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书