H Gene Dossett, Michael Stickels, Rini Desai, Alexander Kozak, Brooke Shanahan, Sailesh Tummala
{"title":"Augmented Reality-Guided Individualized Total Knee Arthroplasty: Initial Clinical Implementation and Results.","authors":"H Gene Dossett, Michael Stickels, Rini Desai, Alexander Kozak, Brooke Shanahan, Sailesh Tummala","doi":"10.5435/JAAOSGlobal-D-25-00318","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Contemporary total knee arthroplasty (TKA) practice has evolved from uniform mechanical alignment to individualized alignment planning in response to growing evidence that a single alignment strategy does not optimize outcomes for all patients. However, precise execution of patient-specific alignment strategies remains challenging with manual instrumentation. Augmented reality (AR) technology addresses this limitation by providing real-time intraoperative visualization of anatomic landmarks and planned resection parameters. In this study, individualized alignment was applied within predefined safety envelopes, including femoral valgus relative to the mechanical axis of 0° to 3°, tibial varus of 0° to 3°, and hip-knee-ankle alignment within 0° to 3° of neutral. All procedures were performed using the Pixee Knee + AR system (Pixee Medical, Besançon, France). Despite growing interest in AR-assisted surgery, clinical data regarding the accuracy, precision, and early outcomes of AR-guided individualized TKA remain limited, providing the rationale for this study.</p><p><strong>Methods: </strong>This retrospective consecutive case series evaluated 50 patients with end-stage knee osteoarthritis who underwent primary TKA using the Pixee Knee + AR system between April and August 2024. All procedures used individualized alignment strategies with patient-specific planning parameters. Radiographic accuracy was assessed using postoperative CT imaging, and validated patient-reported outcome measures were collected at minimum 6-month follow-up.</p><p><strong>Results: </strong>The cohort comprised 45 men and 5 women with mean age 71.4 ± 7.6 years, American Society of Anesthesiologists score 3.0 ± 0.2, and body mass index 31.0 ± 4.1 kg/m2. Alignment accuracy was excellent, with 96% of coronal measurements within 3° of planned values and 53.3% within 1°. Component-specific accuracy rates within 1° were as follows: tibial component 72%, femoral implant 62%, and overall hip-knee-ankle alignment 46%. Four percent of measurements exceeded 3° deviation from planned alignment. No revision surgeries, infections, or mechanical complications occurred during follow-up. Patient-reported outcomes demonstrated notable improvements from preoperative scores: modified single assessment numeric evaluation scores improved 4.7 ± 3.1 points (P < 0.001) and KOOS Jr. normalized scores improved 21.6 ± 23.2 points (P < 0.001).</p><p><strong>Conclusion: </strong>AR-guided individualized TKA demonstrated high accuracy in executing patient-specific alignment plans with favorable early clinical outcomes and no complications at 6 months. These initial results suggest that AR technology may provide a viable alternative for precise implementation of individualized alignment strategies, although larger studies with longer follow-up are needed to establish long-term efficacy and safety.</p>","PeriodicalId":45062,"journal":{"name":"Journal of the American Academy of Orthopaedic Surgeons Global Research and Reviews","volume":"10 8","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2026-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13395493/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Academy of Orthopaedic Surgeons Global Research and Reviews","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5435/JAAOSGlobal-D-25-00318","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Contemporary total knee arthroplasty (TKA) practice has evolved from uniform mechanical alignment to individualized alignment planning in response to growing evidence that a single alignment strategy does not optimize outcomes for all patients. However, precise execution of patient-specific alignment strategies remains challenging with manual instrumentation. Augmented reality (AR) technology addresses this limitation by providing real-time intraoperative visualization of anatomic landmarks and planned resection parameters. In this study, individualized alignment was applied within predefined safety envelopes, including femoral valgus relative to the mechanical axis of 0° to 3°, tibial varus of 0° to 3°, and hip-knee-ankle alignment within 0° to 3° of neutral. All procedures were performed using the Pixee Knee + AR system (Pixee Medical, Besançon, France). Despite growing interest in AR-assisted surgery, clinical data regarding the accuracy, precision, and early outcomes of AR-guided individualized TKA remain limited, providing the rationale for this study.
Methods: This retrospective consecutive case series evaluated 50 patients with end-stage knee osteoarthritis who underwent primary TKA using the Pixee Knee + AR system between April and August 2024. All procedures used individualized alignment strategies with patient-specific planning parameters. Radiographic accuracy was assessed using postoperative CT imaging, and validated patient-reported outcome measures were collected at minimum 6-month follow-up.
Results: The cohort comprised 45 men and 5 women with mean age 71.4 ± 7.6 years, American Society of Anesthesiologists score 3.0 ± 0.2, and body mass index 31.0 ± 4.1 kg/m2. Alignment accuracy was excellent, with 96% of coronal measurements within 3° of planned values and 53.3% within 1°. Component-specific accuracy rates within 1° were as follows: tibial component 72%, femoral implant 62%, and overall hip-knee-ankle alignment 46%. Four percent of measurements exceeded 3° deviation from planned alignment. No revision surgeries, infections, or mechanical complications occurred during follow-up. Patient-reported outcomes demonstrated notable improvements from preoperative scores: modified single assessment numeric evaluation scores improved 4.7 ± 3.1 points (P < 0.001) and KOOS Jr. normalized scores improved 21.6 ± 23.2 points (P < 0.001).
Conclusion: AR-guided individualized TKA demonstrated high accuracy in executing patient-specific alignment plans with favorable early clinical outcomes and no complications at 6 months. These initial results suggest that AR technology may provide a viable alternative for precise implementation of individualized alignment strategies, although larger studies with longer follow-up are needed to establish long-term efficacy and safety.