Quantitative analysis of thermal recovery using dynamic infrared thermography: a methodological proof-of-concept with multi-time-constant modeling.

IF 2.5 4区 医学 Q3 BIOPHYSICS
José-Marco Balleza Ordaz, Moisés Padilla, César Bravo-Alvarado, Svetlana Kashina, Gonzalo Páez, Manuel Servín
{"title":"Quantitative analysis of thermal recovery using dynamic infrared thermography: a methodological proof-of-concept with multi-time-constant modeling.","authors":"José-Marco Balleza Ordaz, Moisés Padilla, César Bravo-Alvarado, Svetlana Kashina, Gonzalo Páez, Manuel Servín","doi":"10.1088/1361-6579/ae95af","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>To evaluate thermal recovery after controlled cooling using dynamic infrared thermography and to determine whether the recovery process can be described using distinct temporal components associated with different heat transfer dynamics.<i>Approach.</i>A controlled cooling protocol was applied to the plantar region of the foot, followed by thermal recovery monitoring using a radiometric infrared camera. Temperature evolution was analyzed using a two-time-constant exponential model, where<i>τ</i><sub>1</sub>and<i>τ</i><sub>2</sub>represent the slow and fast recovery components, respectively. A frame-by-frame radiometric calibration procedure was implemented to ensure measurement stability. The distributions of<i>τ</i><sub>1</sub>and<i>τ</i><sub>2</sub>were evaluated under different cooling durations and recovery windows using non-parametric statistics.<i>Main results.</i>Thermal recovery was consistently described by two-time constants that capture distinct temporal regimes. The fast component (<i>τ</i><sub>2</sub>) exhibited relatively compact distributions, particularly in the short recovery window, indicating stable and repeatable behavior. In contrast, the slow component (<i>τ</i><sub>1</sub>) showed larger variability, especially for longer recovery windows. This variability suggests that the slow component (<i>τ</i><sub>1</sub>) is more sensitive to extended thermal dynamics and inter-subject variability than to measurement noise. The results also showed that longer cooling durations increased the relative contribution of the slow recovery component (<i>τ</i><sub>1</sub>), revealing multi-scale thermal recovery behavior.<i>Significance.</i>These findings demonstrate that thermal recovery is not a single-scale process but a multi-time dynamic phenomenon in which slow and fast recovery components provide complementary information. By explicitly separating these temporal components, the proposed framework enables a more detailed characterization of thermal dynamics than single-parameter approaches. As a methodological proof-of-concept, this work supports the use of dynamic infrared thermography as a quantitative tool for physiological measurement and establishes a reproducible basis for future clinical studies.</p>","PeriodicalId":20047,"journal":{"name":"Physiological measurement","volume":" ","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2026-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiological measurement","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6579/ae95af","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective.To evaluate thermal recovery after controlled cooling using dynamic infrared thermography and to determine whether the recovery process can be described using distinct temporal components associated with different heat transfer dynamics.Approach.A controlled cooling protocol was applied to the plantar region of the foot, followed by thermal recovery monitoring using a radiometric infrared camera. Temperature evolution was analyzed using a two-time-constant exponential model, whereτ1andτ2represent the slow and fast recovery components, respectively. A frame-by-frame radiometric calibration procedure was implemented to ensure measurement stability. The distributions ofτ1andτ2were evaluated under different cooling durations and recovery windows using non-parametric statistics.Main results.Thermal recovery was consistently described by two-time constants that capture distinct temporal regimes. The fast component (τ2) exhibited relatively compact distributions, particularly in the short recovery window, indicating stable and repeatable behavior. In contrast, the slow component (τ1) showed larger variability, especially for longer recovery windows. This variability suggests that the slow component (τ1) is more sensitive to extended thermal dynamics and inter-subject variability than to measurement noise. The results also showed that longer cooling durations increased the relative contribution of the slow recovery component (τ1), revealing multi-scale thermal recovery behavior.Significance.These findings demonstrate that thermal recovery is not a single-scale process but a multi-time dynamic phenomenon in which slow and fast recovery components provide complementary information. By explicitly separating these temporal components, the proposed framework enables a more detailed characterization of thermal dynamics than single-parameter approaches. As a methodological proof-of-concept, this work supports the use of dynamic infrared thermography as a quantitative tool for physiological measurement and establishes a reproducible basis for future clinical studies.

利用动态红外热成像定量分析热回收:多时间常数建模的概念验证方法。
目的:利用动态红外热成像技术评估受控冷却后的热恢复,并确定恢复过程是否可以用与不同传热动力学相关的不同时间分量来描述。方法:控制冷却方案应用于足部的足底区域,随后热恢复监测使用辐射红外相机。采用双时间常数指数模型分析温度演化,其中τ 1和τ 2分别代表慢速和快速恢复分量。采用逐帧辐射校准程序确保测量的稳定性。利用非参数统计评估了不同冷却持续时间和恢复窗口下τ 1和τ 2的分布。主要结果:热恢复被一致地描述为两个时间常数,捕获不同的时间制度。快速分量(τ 2)的分布相对紧凑,特别是在较短的恢复窗口内,表明了稳定和可重复的行为。相比之下,慢分量(τ 1)表现出更大的变异性,特别是对于较长的恢复窗口。这种可变性表明,慢分量(τ 1)对扩展的热动力学和主体间可变性比对测量噪声更敏感。结果还表明,较长的冷却时间增加了慢采分量(τ₁)的相对贡献,揭示了多尺度热采行为。意义:这些发现表明热采不是一个单一尺度的过程,而是一个多时间的动态现象,其中慢速和快速的恢复成分提供了互补的信息。通过明确地分离这些时间成分,所提出的框架能够比单参数方法更详细地表征热动力学。作为一种方法学概念验证,这项工作支持动态红外热像仪作为生理测量的定量工具,并为未来的临床研究奠定了可重复的基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Physiological measurement
Physiological measurement 生物-工程:生物医学
CiteScore
5.50
自引率
9.40%
发文量
124
审稿时长
3 months
期刊介绍: Physiological Measurement publishes papers about the quantitative assessment and visualization of physiological function in clinical research and practice, with an emphasis on the development of new methods of measurement and their validation. Papers are published on topics including: applied physiology in illness and health electrical bioimpedance, optical and acoustic measurement techniques advanced methods of time series and other data analysis biomedical and clinical engineering in-patient and ambulatory monitoring point-of-care technologies novel clinical measurements of cardiovascular, neurological, and musculoskeletal systems. measurements in molecular, cellular and organ physiology and electrophysiology physiological modeling and simulation novel biomedical sensors, instruments, devices and systems measurement standards and guidelines.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书