Evaluation of HRV-PRV agreement with autoencoder-based signal quality assessment in resting and dynamic conditions.

IF 2.5 4区 医学 Q3 BIOPHYSICS
Bartosz Olszewski, Agnieszka Uryga, Cyprian Mataczyński, Magdalena Kasprowicz
{"title":"Evaluation of HRV-PRV agreement with autoencoder-based signal quality assessment in resting and dynamic conditions.","authors":"Bartosz Olszewski, Agnieszka Uryga, Cyprian Mataczyński, Magdalena Kasprowicz","doi":"10.1088/1361-6579/ae95ae","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>Pulse-to-pulse intervals obtained from continuous non-invasive blood pressure (CNBP) signals can be used to derive pulse rate variability (PRV). CNBP signals are susceptible to noise and motion artifacts, which can reduce the reliability of PRV and its agreement with heart rate variability (HRV) derived from electrocardiography (ECG). In this study, we applied a pulse-wise, unsupervised quality assessment method for CNBP signals based on a convolutional autoencoder integrating waveform morphology with pulse-level metadata. The aim was to improve the agreement between PRV and HRV metrics.<i>Approach.</i>Two datasets of CNBP and ECG recordings were analyzed: long baseline measurements (15 volunteers, average 40 min) and short recordings with postural changes (53 volunteers; 5 min squat-stand). A convolutional autoencoder was used for pulse-wise quality assessment. HRV metrics were derived from ECG, and PRV metrics were derived from CNBP before and after quality-based pulse selection (PRV). The analysis included standard time-domain indices (SDNN, RMSSD), frequency-domain measures, and nonlinear Poincaré plot descriptors (SD1, SD2). The agreement between HRV and PRV or PRVwas evaluated by Bland-Altman analysis.<i>Main results.</i>PRV systematically overestimated variability compared to HRV. During resting conditions, RMSSD and SDNN were lower for HRV (47.720.6 ms and 71.427.4 ms) than for PRV (61.726.7 ms,= 0.005 and 77.830.0 ms,= 0.003, respectively). After applying quality-based pulse selection, bias decreased fromtoms for RMSSD and fromtoms for SDNN, improving PRV-HRV agreement. During postural changes, PRV also overestimated HRV, but the effect of quality-based pulse selection was less pronounced.<i>Significance.</i>The proposed approach enhances CNBP signal quality without requiring manual labeling, making it suitable for real-world applications. Improved agreement between PRV and HRV may have important clinical implications, particularly when ECG acquisition is impractical or unavailable.</p>","PeriodicalId":20047,"journal":{"name":"Physiological measurement","volume":" ","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2026-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiological measurement","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6579/ae95ae","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective.Pulse-to-pulse intervals obtained from continuous non-invasive blood pressure (CNBP) signals can be used to derive pulse rate variability (PRV). CNBP signals are susceptible to noise and motion artifacts, which can reduce the reliability of PRV and its agreement with heart rate variability (HRV) derived from electrocardiography (ECG). In this study, we applied a pulse-wise, unsupervised quality assessment method for CNBP signals based on a convolutional autoencoder integrating waveform morphology with pulse-level metadata. The aim was to improve the agreement between PRV and HRV metrics.Approach.Two datasets of CNBP and ECG recordings were analyzed: long baseline measurements (15 volunteers, average 40 min) and short recordings with postural changes (53 volunteers; 5 min squat-stand). A convolutional autoencoder was used for pulse-wise quality assessment. HRV metrics were derived from ECG, and PRV metrics were derived from CNBP before and after quality-based pulse selection (PRV). The analysis included standard time-domain indices (SDNN, RMSSD), frequency-domain measures, and nonlinear Poincaré plot descriptors (SD1, SD2). The agreement between HRV and PRV or PRVwas evaluated by Bland-Altman analysis.Main results.PRV systematically overestimated variability compared to HRV. During resting conditions, RMSSD and SDNN were lower for HRV (47.720.6 ms and 71.427.4 ms) than for PRV (61.726.7 ms,= 0.005 and 77.830.0 ms,= 0.003, respectively). After applying quality-based pulse selection, bias decreased fromtoms for RMSSD and fromtoms for SDNN, improving PRV-HRV agreement. During postural changes, PRV also overestimated HRV, but the effect of quality-based pulse selection was less pronounced.Significance.The proposed approach enhances CNBP signal quality without requiring manual labeling, making it suitable for real-world applications. Improved agreement between PRV and HRV may have important clinical implications, particularly when ECG acquisition is impractical or unavailable.

静态和动态条件下HRV-PRV一致性评价与基于自编码器的信号质量评估。
目的:从连续无创血压(CNBP)信号中获得的脉间间隔可用于推导脉率变异性(PRV)。CNBP信号容易受到噪声和运动伪影的影响,这可能会降低PRV的可靠性及其与心电图(ECG)得出的心率变异性(HRV)的一致性。在这项研究中,我们应用了一种基于卷积自编码器的脉冲无监督CNBP信号质量评估方法,该方法将波形形态与脉冲级元数据相结合。目的是改善PRV和HRV指标之间的一致性。分析了两组CNBP和ECG记录数据:长基线测量(15名志愿者,平均40分钟)和短记录(53名志愿者,5分钟蹲立)。使用卷积自编码器进行脉冲质量评估。HRV指标来源于ECG, PRV指标来源于基于质量的脉冲选择PRVclean前后的CNBP。分析方法包括标准时域指标(SDNN、RMSSD)、频域指标和非线性poincar图描述符(SD1、SD2)。采用Bland-Altman分析评价HRV与PRV或PRV clean的一致性。与HRV相比,PRV系统地高估了变异性。静息条件下,HRV组RMSSD和SDNN(47.7±20.6 ms和71.4±27.4 ms)低于PRV组(61.7±26.7 ms,p=0.005和77.8±30.0 ms,p= 0.003)。应用基于质量的脉冲选择后,RMSSD的偏差从-14.0 ms降至-7.3 ms, SDNN的偏差从-6.4 ms降至-3.2 ms,提高了PRV-HRV一致性。在体位变化过程中,PRV也高估了HRV,但基于质量的脉冲选择的影响不太明显。提出的方法提高了CNBP信号质量,而不需要手动标记,使其适合实际应用。改善PRV和HRV之间的一致性可能具有重要的临床意义,特别是当ECG采集不切实际或不可用时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Physiological measurement
Physiological measurement 生物-工程:生物医学
CiteScore
5.50
自引率
9.40%
发文量
124
审稿时长
3 months
期刊介绍: Physiological Measurement publishes papers about the quantitative assessment and visualization of physiological function in clinical research and practice, with an emphasis on the development of new methods of measurement and their validation. Papers are published on topics including: applied physiology in illness and health electrical bioimpedance, optical and acoustic measurement techniques advanced methods of time series and other data analysis biomedical and clinical engineering in-patient and ambulatory monitoring point-of-care technologies novel clinical measurements of cardiovascular, neurological, and musculoskeletal systems. measurements in molecular, cellular and organ physiology and electrophysiology physiological modeling and simulation novel biomedical sensors, instruments, devices and systems measurement standards and guidelines.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书