Validation of Minimally Invasive and Noninvasive Hemodynamic Monitoring in Adolescents: The Pediatric Cardiac Output Monitoring Observational (POGO) Study.

IF 4.9 2区 医学 Q1 CRITICAL CARE MEDICINE
Pediatric Critical Care Medicine Pub Date : 2026-08-01 Epub Date: 2026-08-06 DOI:10.1097/PCC.0000000000003986
Sebastian C Tume, Michael L O'Byrne, Curt Fudge, Marc M Anders, Dipankar Gupta
{"title":"Validation of Minimally Invasive and Noninvasive Hemodynamic Monitoring in Adolescents: The Pediatric Cardiac Output Monitoring Observational (POGO) Study.","authors":"Sebastian C Tume, Michael L O'Byrne, Curt Fudge, Marc M Anders, Dipankar Gupta","doi":"10.1097/PCC.0000000000003986","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Minimally invasive cardiac output (CO) monitoring technologies lack validation in the adolescent population. We aimed to test the accuracy and precision of the FloTrac arterial pressure cardiac output (APCO) and ClearSight photoplethysmography cardiac output (PPGCO; Edwards Lifesciences, Irvine, CA) technologies in adolescents undergoing elective cardiac catheterization.</p><p><strong>Design: </strong>Prospective, single-arm, nonrandomized, observational study.</p><p><strong>Setting: </strong>Cardiac catheterization laboratory at three freestanding pediatric hospitals in the United States.</p><p><strong>Patients: </strong>Adolescent patients 12-18 years of age undergoing surveillance cardiac catheterization after heart transplantation.</p><p><strong>Interventions: </strong>Swan-Ganz pulmonary artery catheterization with the intermittent thermodilution CO (iCO) technique was used as the gold standard for CO measurements. APCO was measured using an existing femoral arterial sheath, and PPGCO was measured utilizing a volumetric cuff placed on the finger of the upper extremities. Two sets of simultaneous iCO, APCO, and PPGCO measurements were compared. Bias and level of concordance were assessed using Bland-Altman analysis.</p><p><strong>Measurements and main results: </strong>Out of the 89 subjects enrolled, 73 underwent measurements and provided a total of 60 sets of measurements for each device. The median age was 16 years (interquartile range [IQR], 14-17 yr) with a median body surface area of 1.6 m2 (IQR, 1.5-1.8 m2). The median averaged intermittent cardiac index was 2.7 L/min/m2 (IQR, 2.3-3.1 L/min/m2). FloTrac APCO mean bias was 0.32 L/min/m2 (IQR, 0.20-0.44 L/min/m2) with a precision of 0.70 L/min/m2 (IQR, 0.58-0.82 L/min/m2). ClearSight PPGCO mean bias was 0.28 L/min/m2 (95% CI, 0.16-0.41 L/min/m2) with a precision of 0.71 L/min/m2 (95% CI, 0.59-0.84 L/min/m2). No serious adverse events were reported related to the devices.</p><p><strong>Conclusions: </strong>The minimally and noninvasive CO measurements with FloTrac and ClearSight APCO show acceptable bias and precision under standardized elective clinical conditions in an adolescent pediatric population, making them useful tools in the routine clinical management of critically ill children.</p>","PeriodicalId":19760,"journal":{"name":"Pediatric Critical Care Medicine","volume":"27 8","pages":"986-997"},"PeriodicalIF":4.9000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Critical Care Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/PCC.0000000000003986","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/6 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Minimally invasive cardiac output (CO) monitoring technologies lack validation in the adolescent population. We aimed to test the accuracy and precision of the FloTrac arterial pressure cardiac output (APCO) and ClearSight photoplethysmography cardiac output (PPGCO; Edwards Lifesciences, Irvine, CA) technologies in adolescents undergoing elective cardiac catheterization.

Design: Prospective, single-arm, nonrandomized, observational study.

Setting: Cardiac catheterization laboratory at three freestanding pediatric hospitals in the United States.

Patients: Adolescent patients 12-18 years of age undergoing surveillance cardiac catheterization after heart transplantation.

Interventions: Swan-Ganz pulmonary artery catheterization with the intermittent thermodilution CO (iCO) technique was used as the gold standard for CO measurements. APCO was measured using an existing femoral arterial sheath, and PPGCO was measured utilizing a volumetric cuff placed on the finger of the upper extremities. Two sets of simultaneous iCO, APCO, and PPGCO measurements were compared. Bias and level of concordance were assessed using Bland-Altman analysis.

Measurements and main results: Out of the 89 subjects enrolled, 73 underwent measurements and provided a total of 60 sets of measurements for each device. The median age was 16 years (interquartile range [IQR], 14-17 yr) with a median body surface area of 1.6 m2 (IQR, 1.5-1.8 m2). The median averaged intermittent cardiac index was 2.7 L/min/m2 (IQR, 2.3-3.1 L/min/m2). FloTrac APCO mean bias was 0.32 L/min/m2 (IQR, 0.20-0.44 L/min/m2) with a precision of 0.70 L/min/m2 (IQR, 0.58-0.82 L/min/m2). ClearSight PPGCO mean bias was 0.28 L/min/m2 (95% CI, 0.16-0.41 L/min/m2) with a precision of 0.71 L/min/m2 (95% CI, 0.59-0.84 L/min/m2). No serious adverse events were reported related to the devices.

Conclusions: The minimally and noninvasive CO measurements with FloTrac and ClearSight APCO show acceptable bias and precision under standardized elective clinical conditions in an adolescent pediatric population, making them useful tools in the routine clinical management of critically ill children.

青少年微创和无创血流动力学监测的有效性验证:儿童心输出量监测观察(POGO)研究。
目的:微创心输出量(CO)监测技术在青少年人群中缺乏验证。我们的目的是测试FloTrac动脉压心输出量(APCO)和ClearSight光容积脉搏图心输出量(PPGCO; Edwards Lifesciences, Irvine, CA)技术在接受选择性心导管插入术的青少年中的准确性和精密度。设计:前瞻性、单臂、非随机、观察性研究。环境:美国三家独立儿科医院的心导管实验室。患者:12-18岁的青少年患者,心脏移植术后接受心导管监护。干预措施:采用间歇性热稀释CO (iCO)技术的Swan-Ganz肺动脉导管置入作为CO测量的金标准。APCO使用现有的股动脉鞘测量,PPGCO使用放置在上肢手指上的体积袖带测量。比较了两组同时测量的iCO、APCO和PPGCO。采用Bland-Altman分析评估偏倚和一致性水平。测量和主要结果:在89名受试者中,73名受试者接受了测量,并为每种设备提供了总共60组测量。年龄中位数为16岁(四分位间距[IQR], 14-17岁),体表面积中位数为1.6 m2 (IQR, 1.5-1.8 m2)。中位平均间歇心脏指数为2.7 L/min/m2 (IQR, 2.3-3.1 L/min/m2)。FloTrac APCO平均偏差为0.32 L/min/m2 (IQR, 0.20-0.44 L/min/m2),精度为0.70 L/min/m2 (IQR, 0.58-0.82 L/min/m2)。ClearSight PPGCO平均偏差为0.28 L/min/m2 (95% CI, 0.16-0.41 L/min/m2),精度为0.71 L/min/m2 (95% CI, 0.59-0.84 L/min/m2)。未报告与器械相关的严重不良事件。结论:FloTrac和ClearSight APCO的微创和无创性CO测量在青少年人群中具有可接受的偏差和精度,在标准化的选择性临床条件下,使其成为危重儿童常规临床管理的有用工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Pediatric Critical Care Medicine
Pediatric Critical Care Medicine 医学-危重病医学
CiteScore
7.40
自引率
14.60%
发文量
991
审稿时长
3-8 weeks
期刊介绍: Pediatric Critical Care Medicine is written for the entire critical care team: pediatricians, neonatologists, respiratory therapists, nurses, and others who deal with pediatric patients who are critically ill or injured. International in scope, with editorial board members and contributors from around the world, the Journal includes a full range of scientific content, including clinical articles, scientific investigations, solicited reviews, and abstracts from pediatric critical care meetings. Additionally, the Journal includes abstracts of selected articles published in Chinese, French, Italian, Japanese, Portuguese, and Spanish translations - making news of advances in the field available to pediatric and neonatal intensive care practitioners worldwide.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书