{"title":"A mobile based antimicrobial susceptibility testing device - prototype development and validation.","authors":"Anu Aravindh, Akanksha Gupta, Manodeep Sen, Anupam Das, Jyotsna Agarwal","doi":"10.25259/IJMR_214_2026","DOIUrl":null,"url":null,"abstract":"<p><p>Background and objectives Antimicrobial resistance is a major concern due to multidrug-resistant pathogens. Advances in smartphone technology provide opportunity to digitise antimicrobial susceptibility testing (AST). This study aimed to develop and validate an in-house semi-automated smartphone application (app) for the measurement and interpretation of AST. Methods In this prospective validation study, an in-house app was developed using an AI-assisted coding workflow. The app uses a digital calibration algorithm that correlates pixel dimensions with millimetres (mm). AST was performed using the Kirby-Bauer disk diffusion method (KBDD) on Escherichia coli (n=48), and Staphylococcus aureus (n=15) and zone diameters were measured manually, interpreted using Clinical and Laboratory Standards Institute (CLSI) followed by analysis of the same plates using the app. S. aureus (14 drugs) required at least two Mueller-Hinton agar (MHA) plates per isolate, while E. coli (22 drugs) required at least three MHA plates per isolate. Results AST was performed on 1,000 antibiotic disks. Zone diameters were measured and interpreted by both methods. Categorical agreement was 90.4%. Unweighted Cohen's Kappa was 0.836 (95% CI: 0.806-0.866). Categorical discrepancies occurred in 96 antibiotic disks. Very major, major, and minor error rates were 0%, 0.83%, and 9.2%, respectively. Interpretation and conclusions The app demonstrated reliable interpretation of AST, with high categorical agreement and less than 1% major error rates, supporting its safety for resistance detection. This approach offers a user-friendly alternative for busy, resource-limited settings that can be used routinely.</p>","PeriodicalId":13349,"journal":{"name":"Indian Journal of Medical Research","volume":"164 2","pages":"220-226"},"PeriodicalIF":2.1000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13466867/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Medical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.25259/IJMR_214_2026","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objectives Antimicrobial resistance is a major concern due to multidrug-resistant pathogens. Advances in smartphone technology provide opportunity to digitise antimicrobial susceptibility testing (AST). This study aimed to develop and validate an in-house semi-automated smartphone application (app) for the measurement and interpretation of AST. Methods In this prospective validation study, an in-house app was developed using an AI-assisted coding workflow. The app uses a digital calibration algorithm that correlates pixel dimensions with millimetres (mm). AST was performed using the Kirby-Bauer disk diffusion method (KBDD) on Escherichia coli (n=48), and Staphylococcus aureus (n=15) and zone diameters were measured manually, interpreted using Clinical and Laboratory Standards Institute (CLSI) followed by analysis of the same plates using the app. S. aureus (14 drugs) required at least two Mueller-Hinton agar (MHA) plates per isolate, while E. coli (22 drugs) required at least three MHA plates per isolate. Results AST was performed on 1,000 antibiotic disks. Zone diameters were measured and interpreted by both methods. Categorical agreement was 90.4%. Unweighted Cohen's Kappa was 0.836 (95% CI: 0.806-0.866). Categorical discrepancies occurred in 96 antibiotic disks. Very major, major, and minor error rates were 0%, 0.83%, and 9.2%, respectively. Interpretation and conclusions The app demonstrated reliable interpretation of AST, with high categorical agreement and less than 1% major error rates, supporting its safety for resistance detection. This approach offers a user-friendly alternative for busy, resource-limited settings that can be used routinely.

一种基于移动的抗菌药物敏感性测试装置-原型开发和验证。
背景和目的由于多重耐药病原体的出现,抗菌素耐药性是一个主要问题。智能手机技术的进步为抗菌药物敏感性试验(AST)的数字化提供了机会。本研究旨在开发和验证用于AST测量和解释的内部半自动智能手机应用程序(app)。方法在这项前瞻性验证研究中,使用人工智能辅助编码工作流开发了内部应用程序。该应用程序使用数字校准算法,将像素尺寸与毫米(mm)相关联。采用Kirby-Bauer圆盘扩散法(KBDD)对大肠杆菌(n=48)进行AST检测,金黄色葡萄球菌(n=15)和区直径进行人工测量,使用临床和实验室标准协会(CLSI)进行解释,然后使用应用程序对相同的板进行分析。金黄色葡萄球菌(14种药物)每个分离物至少需要两个muler - hinton琼脂(MHA)板,而大肠杆菌(22种药物)每个分离物至少需要三个MHA板。结果对1000片抗生素片进行AST检查。用这两种方法测量和解释了区域直径。完全一致的占90.4%。未加权Cohen's Kappa为0.836 (95% CI: 0.806-0.866)。96个抗生素盘出现了分类差异。非常严重、严重和轻微错误率分别为0%、0.83%和9.2%。该应用程序显示AST的可靠解释,具有高度的分类一致性和小于1%的主要错误率,支持其耐药检测的安全性。这种方法为日常使用的繁忙、资源有限的设置提供了一种用户友好的选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.80
自引率
2.40%
发文量
191
审稿时长
3-8 weeks
期刊介绍: The Indian Journal of Medical Research (IJMR) [ISSN 0971-5916] is one of the oldest medical Journals not only in India, but probably in Asia, as it started in the year 1913. The Journal was started as a quarterly (4 issues/year) in 1913 and made bimonthly (6 issues/year) in 1958. It became monthly (12 issues/year) in the year 1964.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书