{"title":"Practical optimization of deep learning models for cuffless blood pressure estimation from photoplethysmography.","authors":"Vikas Khurana, Aejaz Mohammad Pamidi, Bharat Bhushan Joshi, Ganesh Belde, Rajesh Reddy Goutha, Ratan Bajpai, Subodha Kumar, Akram Khan","doi":"10.1088/1361-6579/ae944f","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>To improve deep learning-based cuffless blood pressure (BP) estimation from photoplethysmography (PPG) for continuous, non-invasive monitoring when cuff measurements are impractical, by assessing sampling frequency, systolic BP (SBP) and diastolic BP (DBP) derivation, respiratory rate (RR) effects, and errors at BP extremes.<i>Approach.</i>We analysed 205 850 ten-second paired PPG-arterial BP segments from the medical information mart for intensive care waveform database. A convolutional model with a multiresolution U-Net translated PPG to arterial BP waveforms. Inputs at 125, 62.5, and 31.25 Hz were compared. SBP and DBP were derived by minimum-maximum extraction or by averaging the top 4 systolic peaks and bottom 4 diastolic troughs per segment. Performance was summarized using mean absolute error (MAE).<i>Main results.</i>Inputs at 62.5 Hz reduced MAE versus 125 Hz (SBP 5.24 vs 6.34 mmHg; DBP 2.87 vs 3.27 mmHg), whereas 31.25 Hz increased error (SBP 16.09 mmHg; DBP 9.10 mmHg). Multi-peak averaging outperformed minimum-maximum extraction. MAE varied across RRs, with generally lower errors observed at moderate RRs, and higher errors observed at lower and higher SBP ranges.<i>Significance.</i>Sampling frequency, SBP/DBP derivation, and RR shape error patterns in PPG-only cuffless BP estimation, with higher errors at low and high SBP. These results inform device design for bedside and ambulatory monitoring. However, further validation using subject-level datasets is required to assess clinical applicability and compliance with established validation standards.</p>","PeriodicalId":20047,"journal":{"name":"Physiological measurement","volume":" ","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2026-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiological measurement","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6579/ae944f","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0
Abstract
Objective.To improve deep learning-based cuffless blood pressure (BP) estimation from photoplethysmography (PPG) for continuous, non-invasive monitoring when cuff measurements are impractical, by assessing sampling frequency, systolic BP (SBP) and diastolic BP (DBP) derivation, respiratory rate (RR) effects, and errors at BP extremes.Approach.We analysed 205 850 ten-second paired PPG-arterial BP segments from the medical information mart for intensive care waveform database. A convolutional model with a multiresolution U-Net translated PPG to arterial BP waveforms. Inputs at 125, 62.5, and 31.25 Hz were compared. SBP and DBP were derived by minimum-maximum extraction or by averaging the top 4 systolic peaks and bottom 4 diastolic troughs per segment. Performance was summarized using mean absolute error (MAE).Main results.Inputs at 62.5 Hz reduced MAE versus 125 Hz (SBP 5.24 vs 6.34 mmHg; DBP 2.87 vs 3.27 mmHg), whereas 31.25 Hz increased error (SBP 16.09 mmHg; DBP 9.10 mmHg). Multi-peak averaging outperformed minimum-maximum extraction. MAE varied across RRs, with generally lower errors observed at moderate RRs, and higher errors observed at lower and higher SBP ranges.Significance.Sampling frequency, SBP/DBP derivation, and RR shape error patterns in PPG-only cuffless BP estimation, with higher errors at low and high SBP. These results inform device design for bedside and ambulatory monitoring. However, further validation using subject-level datasets is required to assess clinical applicability and compliance with established validation standards.
期刊介绍:
Physiological Measurement publishes papers about the quantitative assessment and visualization of physiological function in clinical research and practice, with an emphasis on the development of new methods of measurement and their validation.
Papers are published on topics including:
applied physiology in illness and health
electrical bioimpedance, optical and acoustic measurement techniques
advanced methods of time series and other data analysis
biomedical and clinical engineering
in-patient and ambulatory monitoring
point-of-care technologies
novel clinical measurements of cardiovascular, neurological, and musculoskeletal systems.
measurements in molecular, cellular and organ physiology and electrophysiology
physiological modeling and simulation
novel biomedical sensors, instruments, devices and systems
measurement standards and guidelines.