Does rod overhang matter? Clinical impact in adolescent idiopathic scoliosis and Scheuermann's kyphosis.

IF 2.5 Q2 ORTHOPEDICS
Deniz Kargin, Ulas Yavuz, Batuhan Konu
{"title":"Does rod overhang matter? Clinical impact in adolescent idiopathic scoliosis and Scheuermann's kyphosis.","authors":"Deniz Kargin, Ulas Yavuz, Batuhan Konu","doi":"10.52312/jdrs.2026.2615","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The aim of this study was to investigate the potential relationship between rod overhang (RO) and quality of life (QoL) scores, as well as implant-related irritation, in patients with adolescent idiopathic scoliosis (AIS) and Scheuermann's kyphosis (SK).</p><p><strong>Patients and methods: </strong>Between October 2016 and December 2018, a total of 33 pediatric patients with AIS and SK who underwent posterior instrumentation were retrospectively analyzed. On radiographs, the longest RO at both the superior and inferior ends (right or left) was recorded, and patients were grouped according to whether RO exceeded 1 cm. Quality of life outcomes were assessed using the Scoliosis Research Society-22r (SRS-22r), Oswestry Disability Index (ODI), and Short Form-36 (SF-36) questionnaires, and patients were also asked about implant-end irritation.</p><p><strong>Results: </strong>Of the patients, 10 were male and 23 were female. The mean age at the time of operation was 15.18 ± 1.98 years, while the mean age at the latest follow-up was 23.85 ± 1.86 years. The median follow-up was 104.08 months. The mean maximum RO was 11.3 ± 7.8 mm superiorly and 11.1 ± 6.2 mm inferiorly. Superior RO correlated significantly with SF-36 role-physical (r = -0.36, p = 0.04) and vitality (r = -0.43, p = 0.01) subdomains; no other significant QoL correlations were found. Implant-related irritation was reported in eight (n = 3 superior, n = 5 inferior) patients. There was no significant difference in RO between patients who did and did not report implant-related irritation (superior p = 0.18 vs. inferior p = 0.48). There were no significant differences in QoL scores (for superior, inferior, and either end; p > 0.05) or in the rate of implant-related irritation between patients with RO greater or less than 1 cm (superior p = 0.70; inferior and either end p = 1.00).</p><p><strong>Conclusion: </strong>Our study results suggest that rod overhangs up to 3 cm may not be a clinically relevant determinant of patient-reported outcomes or implant-related irritation in AIS and SK surgery. From a clinical perspective, this may help reduce concern regarding minor distal or proximal overhang during posterior instrumentation, particularly when optimal correction and fixation require slight extension of the construct. The absence of a measurable association with QoL or irritation also supports a more flexible intraoperative decision-making approach, prioritizing deformity correction and implant stability over strict limitation of rod length within this range.</p>","PeriodicalId":73560,"journal":{"name":"Joint diseases and related surgery","volume":"37 3","pages":"697-704"},"PeriodicalIF":2.5000,"publicationDate":"2026-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Joint diseases and related surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52312/jdrs.2026.2615","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: The aim of this study was to investigate the potential relationship between rod overhang (RO) and quality of life (QoL) scores, as well as implant-related irritation, in patients with adolescent idiopathic scoliosis (AIS) and Scheuermann's kyphosis (SK).

Patients and methods: Between October 2016 and December 2018, a total of 33 pediatric patients with AIS and SK who underwent posterior instrumentation were retrospectively analyzed. On radiographs, the longest RO at both the superior and inferior ends (right or left) was recorded, and patients were grouped according to whether RO exceeded 1 cm. Quality of life outcomes were assessed using the Scoliosis Research Society-22r (SRS-22r), Oswestry Disability Index (ODI), and Short Form-36 (SF-36) questionnaires, and patients were also asked about implant-end irritation.

Results: Of the patients, 10 were male and 23 were female. The mean age at the time of operation was 15.18 ± 1.98 years, while the mean age at the latest follow-up was 23.85 ± 1.86 years. The median follow-up was 104.08 months. The mean maximum RO was 11.3 ± 7.8 mm superiorly and 11.1 ± 6.2 mm inferiorly. Superior RO correlated significantly with SF-36 role-physical (r = -0.36, p = 0.04) and vitality (r = -0.43, p = 0.01) subdomains; no other significant QoL correlations were found. Implant-related irritation was reported in eight (n = 3 superior, n = 5 inferior) patients. There was no significant difference in RO between patients who did and did not report implant-related irritation (superior p = 0.18 vs. inferior p = 0.48). There were no significant differences in QoL scores (for superior, inferior, and either end; p > 0.05) or in the rate of implant-related irritation between patients with RO greater or less than 1 cm (superior p = 0.70; inferior and either end p = 1.00).

Conclusion: Our study results suggest that rod overhangs up to 3 cm may not be a clinically relevant determinant of patient-reported outcomes or implant-related irritation in AIS and SK surgery. From a clinical perspective, this may help reduce concern regarding minor distal or proximal overhang during posterior instrumentation, particularly when optimal correction and fixation require slight extension of the construct. The absence of a measurable association with QoL or irritation also supports a more flexible intraoperative decision-making approach, prioritizing deformity correction and implant stability over strict limitation of rod length within this range.

杆的悬垂重要吗?青少年特发性脊柱侧凸和舒尔曼后凸的临床影响。
目的:本研究的目的是调查青少年特发性脊柱侧凸(AIS)和Scheuermann's后凸(SK)患者的杆悬垂(RO)和生活质量(QoL)评分以及植入物相关刺激之间的潜在关系。患者和方法:2016年10月至2018年12月,回顾性分析33例接受后路内固定的儿童AIS和SK患者。x线片记录上、下两端(右或左)最长RO值,根据RO值是否超过1cm进行分组。使用脊柱侧凸研究协会-22r (SRS-22r)、Oswestry残疾指数(ODI)和SF-36问卷评估生活质量结果,并询问患者关于植入物末端刺激的问题。结果:男性10例,女性23例。手术时平均年龄15.18±1.98岁,最后一次随访时平均年龄23.85±1.86岁。中位随访时间为104.08个月。平均最大RO为11.3±7.8 mm, 11.1±6.2 mm。优越RO与SF-36角色-物理(r = -0.36, p = 0.04)和活力(r = -0.43, p = 0.01)子域显著相关;未发现其他显著的生活质量相关性。8例(n = 3上位,n = 5下位)患者报告了与种植体相关的刺激。有和没有报告植入物相关刺激的患者的RO无显著差异(p = 0.18 vs. p = 0.48)。RO大于或小于1 cm的患者在生活质量评分(上、下、两端;p < 0.05)或植入物相关刺激率方面无显著差异(上、下、两端p = 0.70;下、两端p = 1.00)。结论:我们的研究结果表明,在AIS和SK手术中,高达3cm的杆悬垂可能不是患者报告结果或植入物相关刺激的临床相关决定因素。从临床角度来看,这可能有助于减少后路内固定过程中对小的远端或近端悬垂的担忧,特别是当最佳矫正和固定需要稍微伸展构造时。没有可测量的与生活质量或刺激的关联也支持更灵活的术中决策方法,优先考虑畸形矫正和种植体稳定性,而不是严格限制杆长度在这个范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书