Minimum 10-year outcomes of highly cross-linked polyethylene in total hip arthroplasty for hip dysplasia: Effect of cup inclination in a matched comparative study.

IF 2.5 Q2 ORTHOPEDICS
Byung-Chan Choi, Kyung-Jae Lee, Byung-Woo Min, Ho-Sung Suh
{"title":"Minimum 10-year outcomes of highly cross-linked polyethylene in total hip arthroplasty for hip dysplasia: Effect of cup inclination in a matched comparative study.","authors":"Byung-Chan Choi, Kyung-Jae Lee, Byung-Woo Min, Ho-Sung Suh","doi":"10.52312/jdrs.2026.2702","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study aims to compare the long-term outcome of highly cross-linked polyethylene (HXLPE) in hip dysplasia with osteonecrosis of the femoral head (ONFH) and evaluate the effect of cup inclination on HXLPE wear after total hip arthroplasty (THA) during a minimum 10-year follow-up.</p><p><strong>Patients and methods: </strong>Between January 2000 and December 2012, a total of 124 patients who underwent primary THA for hip dysplasia or ONFH with a minimum 10-year follow-up were retrospectively analyzed. A total of 62 patients were successfully matched between the two groups (ONFH group, n = 62 and hip dysplasia group, n = 62). Primary outcomes included acetabular cup inclination, anteversion, and wear rates of HXLPE. Based on cup inclination, both groups were divided into three subgroups, classified as (1) ≤ 45°, (2) < 45° to < 50°, and (3) ≥ 55°. Secondary outcomes included the clinical score and radiographic findings of osteolysis, implant loosening, stress shielding, and heterotopic ossification. Kaplan-Meier curve and Cox regression test were used to compare the implant survivorship in the full cohort prior to exclusion and matching (178 hip dysplasia and 397 ONFH patients).</p><p><strong>Results: </strong>There was no significant difference in survival rate without revision of prosthesis at 10-year between two groups (hip dysplasia: 94.7%, 95% confidence interval [CI]: 91.1% to 98.4% vs. ONFH: 95.7% (95% CI: 93.3% to 98.2%) (p = 0.4) Cup inclination was significantly steeper in the hip dysplasia group (47.6°, 95% CI: 46.0° to 49.3°) than in the ONFH group (43.9°, 95% CI: 42.3° to 45.5°) (p = 0.002). Steep cup inclination (> 55°) was significantly more frequent in the hip dysplasia group (11.3%, 7/62) than in the ONFH group (6.5%, 4/62; p = 0.006). However, wear rates of HXLPE were not significantly different between groups, and no correlation was found between cup inclination and HXLPE wear rate. No progressive osteolysis or prosthetic loosening was observed during follow-up.</p><p><strong>Conclusion: </strong>Although patients with hip dysplasia demonstrated a steeper mean cup inclination and a higher incidence of steep cup positioning compared to those with ONFH, implant survivorship remained comparable between groups in the overall cohort. In the matched cohort analysis, HXLPE wear rates and clinical outcomes were also comparable between the groups. These findings suggest that, despite technical challenges in acetabular positioning, the use of HXLPE in THA for hip dysplasia provides satisfactory long-term performance and may alleviate concerns regarding cup inclination-related wear.</p>","PeriodicalId":73560,"journal":{"name":"Joint diseases and related surgery","volume":"37 3","pages":"602-613"},"PeriodicalIF":2.5000,"publicationDate":"2026-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Joint diseases and related surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52312/jdrs.2026.2702","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: This study aims to compare the long-term outcome of highly cross-linked polyethylene (HXLPE) in hip dysplasia with osteonecrosis of the femoral head (ONFH) and evaluate the effect of cup inclination on HXLPE wear after total hip arthroplasty (THA) during a minimum 10-year follow-up.

Patients and methods: Between January 2000 and December 2012, a total of 124 patients who underwent primary THA for hip dysplasia or ONFH with a minimum 10-year follow-up were retrospectively analyzed. A total of 62 patients were successfully matched between the two groups (ONFH group, n = 62 and hip dysplasia group, n = 62). Primary outcomes included acetabular cup inclination, anteversion, and wear rates of HXLPE. Based on cup inclination, both groups were divided into three subgroups, classified as (1) ≤ 45°, (2) < 45° to < 50°, and (3) ≥ 55°. Secondary outcomes included the clinical score and radiographic findings of osteolysis, implant loosening, stress shielding, and heterotopic ossification. Kaplan-Meier curve and Cox regression test were used to compare the implant survivorship in the full cohort prior to exclusion and matching (178 hip dysplasia and 397 ONFH patients).

Results: There was no significant difference in survival rate without revision of prosthesis at 10-year between two groups (hip dysplasia: 94.7%, 95% confidence interval [CI]: 91.1% to 98.4% vs. ONFH: 95.7% (95% CI: 93.3% to 98.2%) (p = 0.4) Cup inclination was significantly steeper in the hip dysplasia group (47.6°, 95% CI: 46.0° to 49.3°) than in the ONFH group (43.9°, 95% CI: 42.3° to 45.5°) (p = 0.002). Steep cup inclination (> 55°) was significantly more frequent in the hip dysplasia group (11.3%, 7/62) than in the ONFH group (6.5%, 4/62; p = 0.006). However, wear rates of HXLPE were not significantly different between groups, and no correlation was found between cup inclination and HXLPE wear rate. No progressive osteolysis or prosthetic loosening was observed during follow-up.

Conclusion: Although patients with hip dysplasia demonstrated a steeper mean cup inclination and a higher incidence of steep cup positioning compared to those with ONFH, implant survivorship remained comparable between groups in the overall cohort. In the matched cohort analysis, HXLPE wear rates and clinical outcomes were also comparable between the groups. These findings suggest that, despite technical challenges in acetabular positioning, the use of HXLPE in THA for hip dysplasia provides satisfactory long-term performance and may alleviate concerns regarding cup inclination-related wear.

高度交联聚乙烯全髋关节置换术治疗髋关节发育不良的最小10年结果:一项匹配比较研究中杯倾角的影响。
目的:本研究旨在比较高度交联聚乙烯(HXLPE)治疗髋关节发育不良伴股骨头坏死(ONFH)的长期疗效,并在至少10年的随访中评估全髋关节置换术(THA)后高度交联聚乙烯(HXLPE)倾斜度对HXLPE磨损的影响。患者和方法:在2000年1月至2012年12月期间,回顾性分析了124例因髋关节发育不良或ONFH接受原发性THA治疗的患者,随访时间至少为10年。两组共成功匹配62例患者(ONFH组,n = 62,髋关节发育不良组,n = 62)。主要结果包括髋臼杯倾角、前倾和HXLPE的磨损率。根据杯倾角,两组均分为3个亚组,分别为(1)≤45°、(2)< 45°~ < 50°、(3)≥55°。次要结果包括临床评分和骨溶解、植入物松动、应力屏蔽和异位骨化的影像学表现。采用Kaplan-Meier曲线和Cox回归检验比较排除和匹配前全队列(178例髋关节发育不良患者和397例ONFH患者)的种植体存活率。结果:两组无假体翻修的10年生存率无显著差异(髋关节发育不良组:94.7%,95%可信区间[CI]: 91.1% ~ 98.4%,而ONFH组:95.7% (95% CI: 93.3% ~ 98.2%) (p = 0.4)。髋关节发育不良组的杯倾角(47.6°,95% CI: 46.0°~ 49.3°)明显大于ONFH组(43.9°,95% CI: 42.3°~ 45.5°)(p = 0.002)。髋部发育不良组(11.3%,7/62)明显高于ONFH组(6.5%,4/62,p = 0.006)。HXLPE的磨损率组间差异不显著,杯倾角与HXLPE磨损率无相关性。随访期间未见进行性骨溶解或假体松动。结论:尽管与ONFH患者相比,髋关节发育不良患者表现出更陡峭的平均杯倾角和更高的陡峭杯位发生率,但在整个队列中,各组之间的植入物存活率仍然具有可比性。在匹配队列分析中,HXLPE磨损率和临床结果在两组之间也具有可比性。这些研究结果表明,尽管在髋臼定位方面存在技术挑战,但在髋关节发育不良的THA中使用HXLPE提供了令人满意的长期效果,并可能减轻对髋臼倾斜相关磨损的担忧。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书