Bridging the gap: intraoperative esophageal stent used as a scaffold for the treatment of complete postsurgical gastroesophageal anastomosis dehiscence
{"title":"Bridging the gap: intraoperative esophageal stent used as a scaffold for the treatment of complete postsurgical gastroesophageal anastomosis dehiscence","authors":"Patricia Ziegler MD, Agnieszka Maniak MD, John Aversa MD, Christopher Chapman MD, Ajaypal Singh MD, Irving Waxman MD, Nicole Geissen MD, Neal Mehta MD","doi":"10.1016/j.vgie.2026.03.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and Aims</h3><div>Esophagogastric (EG) anastomotic leaks are serious adverse events after esophagectomy. Endoscopic stent placement has become an effective, minimally invasive option that promotes healing. While esophageal stents maintain luminal continuity, technical success rates are as high as 90.9%. A 62-year-old man with esophageal adenocarcinoma presented 12 days after McKeown esophagectomy with dyspnea and empyema. Imaging and chest tube output suggested an anastomotic leak. The aim of this study was to display the utility of esophageal stent placement even in cases of complete EG dehiscence.</div></div><div><h3>Methods</h3><div>Intraoperative exploration revealed complete EG dehiscence. Using robotic surgical guidance, we advanced a gastroscope through the mediastinum into the stomach, and a guidewire was passed to facilitate placement of a 20- × 100-mm fully covered self-expandable metal stent. Given the emergent intraoperative nature of the case and the use of a travel cart, endoscopic images are limited or mostly unavailable.</div></div><div><h3>Results</h3><div>The stent provided a scaffold for reapproximation and repair with interrupted sutures and biological mesh. The patient recovered uneventfully, resumed tube feeds, and advanced to oral intake within 2 months. The stent was removed 4 months after placement without stricture or need for dilation.</div></div><div><h3>Conclusions</h3><div>Complete EG dehiscence typically necessitates high-risk surgical repair. In this case, endoscopic stent placement enabled luminal restoration and guided repair, demonstrating a novel multidisciplinary approach to a complex adverse event. Intraoperative endoscopic stent placement can successfully manage complete anastomotic dehiscence, emphasizing the value of coordinated surgical/endoscopic strategies to preserve function.</div></div>","PeriodicalId":55855,"journal":{"name":"VideoGIE","volume":"11 8","pages":"Pages 321-324"},"PeriodicalIF":0.0000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"VideoGIE","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468448126000615","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/27 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Background and Aims
Esophagogastric (EG) anastomotic leaks are serious adverse events after esophagectomy. Endoscopic stent placement has become an effective, minimally invasive option that promotes healing. While esophageal stents maintain luminal continuity, technical success rates are as high as 90.9%. A 62-year-old man with esophageal adenocarcinoma presented 12 days after McKeown esophagectomy with dyspnea and empyema. Imaging and chest tube output suggested an anastomotic leak. The aim of this study was to display the utility of esophageal stent placement even in cases of complete EG dehiscence.
Methods
Intraoperative exploration revealed complete EG dehiscence. Using robotic surgical guidance, we advanced a gastroscope through the mediastinum into the stomach, and a guidewire was passed to facilitate placement of a 20- × 100-mm fully covered self-expandable metal stent. Given the emergent intraoperative nature of the case and the use of a travel cart, endoscopic images are limited or mostly unavailable.
Results
The stent provided a scaffold for reapproximation and repair with interrupted sutures and biological mesh. The patient recovered uneventfully, resumed tube feeds, and advanced to oral intake within 2 months. The stent was removed 4 months after placement without stricture or need for dilation.
Conclusions
Complete EG dehiscence typically necessitates high-risk surgical repair. In this case, endoscopic stent placement enabled luminal restoration and guided repair, demonstrating a novel multidisciplinary approach to a complex adverse event. Intraoperative endoscopic stent placement can successfully manage complete anastomotic dehiscence, emphasizing the value of coordinated surgical/endoscopic strategies to preserve function.
期刊介绍:
VideoGIE, an official video journal of the American Society for Gastrointestinal Endoscopy, is an Open Access, online-only journal to serve patients with digestive diseases. VideoGIE publishes original, single-blinded peer-reviewed video case reports and case series of endoscopic procedures used in the study, diagnosis, and treatment of digestive diseases. Videos demonstrate use of endoscopic systems, devices, and techniques; report outcomes of endoscopic interventions; and educate physicians and patients about gastrointestinal endoscopy. VideoGIE serves the educational needs of endoscopists in training as well as advanced endoscopists, endoscopy staff and industry, and patients. VideoGIE brings video commentaries from experts, legends, committees, and leadership of the society. Careful adherence to submission guidelines will avoid unnecessary delays, as incomplete submissions may be returned to the authors before initiation of the peer review process.