Trueness and scanning time of complete-arch intraoral scans of edentulous arches with implants under different moisture conditions: Effects of splinting-aid, scan body height, and scanner.

IF 3.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Cecília Santos Galvão, Fabiana Silveira Ramalho Moreira, Annie Karoline Bezerra de Medeiros, Gabriela Panca Sabatini, Burak Yilmaz, Adriana da Fonte Porto Carreiro
{"title":"Trueness and scanning time of complete-arch intraoral scans of edentulous arches with implants under different moisture conditions: Effects of splinting-aid, scan body height, and scanner.","authors":"Cecília Santos Galvão, Fabiana Silveira Ramalho Moreira, Annie Karoline Bezerra de Medeiros, Gabriela Panca Sabatini, Burak Yilmaz, Adriana da Fonte Porto Carreiro","doi":"10.1111/jopr.70204","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This in vitro study evaluated the influence of the presence of saliva in varying levels on the trueness and scanning time of complete-arch intraoral scans for implant-supported prostheses, considering different scan body heights, splinting protocols, and scanners.</p><p><strong>Materials and methods: </strong>A three-dimensionally (3D)-printed edentulous maxillary model with six implants and multi-unit abutments was digitized using a metrology-grade industrial scanner (Artec Micro), using polyetheretherketone scan bodies (ISBs) of two heights (short: 4.5 mm and tall: 8.0 mm). The model was also scanned with three intraoral scanners (IOSs) (TRIOS 5 [TR], NeoScan 1000 [NS], and Primescan [PS]) under two splinting wire aids (splinted and non-splinted) and dry or artificial saliva-moisturized (lightly or highly) conditions. A total of 192 scans (n = 8 per experimental condition) were analyzed. Scanning time was recorded with a stopwatch, and trueness was analyzed as root mean square (RMS) deviation when industrial and IOS scans were aligned using Geomagic Control X. Data were analyzed with Kruskal-Wallis, Mann-Whitney U, and Bonferroni-adjusted pairwise comparisons (α = 0.05).</p><p><strong>Results: </strong>Saliva significantly affected trueness and scan time, with higher moisture levels resulting in greater deviations (p < 0.001) and longer acquisition times for all tested IOSs (p < 0.001). IOS type, ISB height, and scan-aid also had significant effects on scan trueness (p < 0.001). TR presented the lowest RMS values, followed by PS and NS. Under moisture conditions, short ISBs and non-splinted configurations produced more reliable scans (p < 0.001). Short ISBs consistently reduced total scanning time compared with tall ISBs (p < 0.001). PS demonstrated the shortest scanning times under dry and highly moisturized conditions, whereas NS combined with short ISBs showed the fastest acquisition under light moisture conditions.</p><p><strong>Conclusion: </strong>The simulation of intraoral saliva presence compromised scan trueness, particularly when moisture level increased. Clinically, minimizing saliva presence during scans and selecting appropriate-height ISBs can enhance trueness for digital implant scans. Although scan-aid may reduce scanning time, its use should be limited to situations in which stabilization is critical, such as long edentulous arches or long interimplant distances, as these conditions may increase optical deviations in the presence of saliva. These findings support the refinement of clinical protocols for complete-arch implant scans, emphasizing saliva control and careful scan strategy selection to improve trueness of digital edentulous scans.</p>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":" ","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2026-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jopr.70204","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This in vitro study evaluated the influence of the presence of saliva in varying levels on the trueness and scanning time of complete-arch intraoral scans for implant-supported prostheses, considering different scan body heights, splinting protocols, and scanners.

Materials and methods: A three-dimensionally (3D)-printed edentulous maxillary model with six implants and multi-unit abutments was digitized using a metrology-grade industrial scanner (Artec Micro), using polyetheretherketone scan bodies (ISBs) of two heights (short: 4.5 mm and tall: 8.0 mm). The model was also scanned with three intraoral scanners (IOSs) (TRIOS 5 [TR], NeoScan 1000 [NS], and Primescan [PS]) under two splinting wire aids (splinted and non-splinted) and dry or artificial saliva-moisturized (lightly or highly) conditions. A total of 192 scans (n = 8 per experimental condition) were analyzed. Scanning time was recorded with a stopwatch, and trueness was analyzed as root mean square (RMS) deviation when industrial and IOS scans were aligned using Geomagic Control X. Data were analyzed with Kruskal-Wallis, Mann-Whitney U, and Bonferroni-adjusted pairwise comparisons (α = 0.05).

Results: Saliva significantly affected trueness and scan time, with higher moisture levels resulting in greater deviations (p < 0.001) and longer acquisition times for all tested IOSs (p < 0.001). IOS type, ISB height, and scan-aid also had significant effects on scan trueness (p < 0.001). TR presented the lowest RMS values, followed by PS and NS. Under moisture conditions, short ISBs and non-splinted configurations produced more reliable scans (p < 0.001). Short ISBs consistently reduced total scanning time compared with tall ISBs (p < 0.001). PS demonstrated the shortest scanning times under dry and highly moisturized conditions, whereas NS combined with short ISBs showed the fastest acquisition under light moisture conditions.

Conclusion: The simulation of intraoral saliva presence compromised scan trueness, particularly when moisture level increased. Clinically, minimizing saliva presence during scans and selecting appropriate-height ISBs can enhance trueness for digital implant scans. Although scan-aid may reduce scanning time, its use should be limited to situations in which stabilization is critical, such as long edentulous arches or long interimplant distances, as these conditions may increase optical deviations in the presence of saliva. These findings support the refinement of clinical protocols for complete-arch implant scans, emphasizing saliva control and careful scan strategy selection to improve trueness of digital edentulous scans.

不同湿度条件下无牙种植体全弓口腔内扫描的正确率和扫描时间:夹板辅助、扫描体高度和扫描仪的影响
目的:本体外研究在考虑不同扫描体高度、夹板方案和扫描仪的情况下,评估不同水平唾液的存在对种植体支撑假体全弓口内扫描的准确性和扫描时间的影响。材料和方法:使用计量级工业扫描仪(Artec Micro),采用两种高度(短4.5 mm和高8.0 mm)的聚醚醚酮扫描体(isb),对具有6个种植体和多单元基台的三维(3D)打印的无牙上颌模型进行数字化。在两种夹板钢丝辅助工具(夹板和非夹板)和干燥或人工唾液湿润(轻度或高度)条件下,使用三台口内扫描仪(TRIOS 5 [TR], NeoScan 1000 [NS]和Primescan [PS])对模型进行扫描。共分析192张扫描图(每个实验条件n = 8)。用秒表记录扫描时间,并用Geomagic Control x对工业扫描和IOS扫描时的均方根(RMS)偏差分析准确率。数据采用Kruskal-Wallis、Mann-Whitney U和bonferroni校正两两比较(α = 0.05)进行分析。结果:唾液显著影响扫描正确率和扫描时间,较高的湿度水平导致更大的偏差(p结论:口腔内唾液存在的模拟会损害扫描正确率,特别是当湿度水平增加时。临床上,在扫描过程中尽量减少唾液的存在并选择适当高度的isb可以提高数字植入扫描的准确性。虽然扫描辅助可以减少扫描时间,但它的使用应限制在稳定至关重要的情况下,如无牙弓长或种植体间距离长,因为这些情况可能会增加唾液存在下的光学偏差。这些发现支持完善全牙弓种植体扫描的临床方案,强调唾液控制和仔细的扫描策略选择,以提高无牙数字扫描的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.90
自引率
15.00%
发文量
171
审稿时长
6-12 weeks
期刊介绍: The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书