Direct measurements of alveolar gas in mechanically ventilated humans.

IF 2.5 4区 医学 Q3 BIOPHYSICS
Gerardo Tusman, Matías Nicolás, Alejandro Carmona, Fernando Suarez Sipmann, Stephan H Böhm
{"title":"Direct measurements of alveolar gas in mechanically ventilated humans<sup />.","authors":"Gerardo Tusman, Matías Nicolás, Alejandro Carmona, Fernando Suarez Sipmann, Stephan H Böhm","doi":"10.1088/1361-6579/ae9036","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>The composition of alveolar gases is based on theoretical assumptions. The role of expired samples at the airway opening in representing the true value of mean alveolar gas remains a subject of debate. We hypothesized that phase III of oxygrams and capnograms obtained at the airway opening must be qualitative similar to the one found at the lung acini. The aim of this study is to test this hypothesis, analyzing the phase III of breath-by-breath samples of airway and alveolar gases from mechanically ventilated patients.<i>Approach.</i>The study compared expired gases at the airway opening and direct gas samples taken from peripheral lung parenchyma in ventilated patients undergoing thoracic surgery. We used video-assisted lobectomies as a model to get direct alveolar gas samples from the lobe that was removed by surgery.<i>Main results.</i>In ten anesthetized patients before lobectomy, the corresponding lung lobe was punctured by a 20 G angiocath at ∼5 mm of depth and then connected via a sampling line to sidestream and mainstream capnographs. An oscillating pattern in synchrony with the mechanical breath cycles was observed in the alveolar CO<sub>2</sub>and O<sub>2</sub>samples. The alveolar capnograms and oxygrams revealed an absence of phase I, very short phase II, and a similar phase III. The slope of phase III of the expired curves at the airway opening [median 2.20 (inter-quartile range 1.28) mmHg s<sup>-1</sup>] were similar to the one of the alveolar mainstream capnograms [median 2.18 (inter-quartile range 1.24) mmHg s<sup>-1</sup>;<i>p</i>= 0.76].<i>Significance.</i>Our findings suggest that alveolar gas can be reliably sampled at the airway opening. The similarity in the slopes of phase III between airway and alveolar samples highlights the significance of continuous gas diffusion through the alveolar-capillary membrane as well as the presence of convection- and diffusion-dependent inhomogeneities in their origin.</p>","PeriodicalId":20047,"journal":{"name":"Physiological measurement","volume":" ","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2026-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiological measurement","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6579/ae9036","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective.The composition of alveolar gases is based on theoretical assumptions. The role of expired samples at the airway opening in representing the true value of mean alveolar gas remains a subject of debate. We hypothesized that phase III of oxygrams and capnograms obtained at the airway opening must be qualitative similar to the one found at the lung acini. The aim of this study is to test this hypothesis, analyzing the phase III of breath-by-breath samples of airway and alveolar gases from mechanically ventilated patients.Approach.The study compared expired gases at the airway opening and direct gas samples taken from peripheral lung parenchyma in ventilated patients undergoing thoracic surgery. We used video-assisted lobectomies as a model to get direct alveolar gas samples from the lobe that was removed by surgery.Main results.In ten anesthetized patients before lobectomy, the corresponding lung lobe was punctured by a 20 G angiocath at ∼5 mm of depth and then connected via a sampling line to sidestream and mainstream capnographs. An oscillating pattern in synchrony with the mechanical breath cycles was observed in the alveolar CO2and O2samples. The alveolar capnograms and oxygrams revealed an absence of phase I, very short phase II, and a similar phase III. The slope of phase III of the expired curves at the airway opening [median 2.20 (inter-quartile range 1.28) mmHg s-1] were similar to the one of the alveolar mainstream capnograms [median 2.18 (inter-quartile range 1.24) mmHg s-1;p= 0.76].Significance.Our findings suggest that alveolar gas can be reliably sampled at the airway opening. The similarity in the slopes of phase III between airway and alveolar samples highlights the significance of continuous gas diffusion through the alveolar-capillary membrane as well as the presence of convection- and diffusion-dependent inhomogeneities in their origin.

机械通气人体肺泡气体的直接测量。
目的:肺泡气体的组成是基于理论假设。在气道开口处的过期样品在代表平均肺泡气体的真实值中的作用仍然是一个有争议的主题。我们假设在气道开口处获得的III期氧合图和碳流图必须与在肺腺泡处发现的定性相似。本研究的目的是验证这一假设,分析机械通气患者气道和肺泡气体的第三期呼吸样本。方法:比较胸外科手术通气患者气道开口处的气体和肺周围实质直接气体样本。我们使用视频辅助肺叶切除术作为模型,直接从手术切除的肺叶中获取肺泡气体样本。主要结果:10例肺叶切除术前麻醉患者,用20G血管导管在⁓5 mm深度穿刺相应肺叶,然后通过采样线连接侧流和主流肺叶记录仪。在肺泡CO2和O2样本中观察到与机械呼吸周期同步的振荡模式。肺泡碳酸图和氧描记图显示I期缺失,II期非常短,III期相似。气道开口处III期过期曲线斜率[中位数2.20(四分位间距1.28)mmHg/s]与肺泡主流血流图斜率[中位数2.18(四分位间距1.24)mmHg/s]相似;P = 0.76]。意义:我们的研究结果表明,在气道开口处可以可靠地取样肺泡气体。气道和肺泡样品在III相斜率上的相似性突出了气体通过肺泡毛细血管膜连续扩散的重要性,以及它们起源中对流和扩散依赖的不均匀性的存在。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Physiological measurement
Physiological measurement 生物-工程:生物医学
CiteScore
5.50
自引率
9.40%
发文量
124
审稿时长
3 months
期刊介绍: Physiological Measurement publishes papers about the quantitative assessment and visualization of physiological function in clinical research and practice, with an emphasis on the development of new methods of measurement and their validation. Papers are published on topics including: applied physiology in illness and health electrical bioimpedance, optical and acoustic measurement techniques advanced methods of time series and other data analysis biomedical and clinical engineering in-patient and ambulatory monitoring point-of-care technologies novel clinical measurements of cardiovascular, neurological, and musculoskeletal systems. measurements in molecular, cellular and organ physiology and electrophysiology physiological modeling and simulation novel biomedical sensors, instruments, devices and systems measurement standards and guidelines.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书