{"title":"Optimizing Radiation Therapy Setup Through Integrated Gantry-Based Display of Multimodal Setup Information","authors":"Stephanie Sae,&nbsp;Edwin Chan","doi":"10.1016/j.jmir.2026.102376","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose/Aim</h3><div>For over a decade, our institution relied on free-text setup notes within the MOSAIQ notes section to guide radiation treatment delivery. With the installation of an Elekta Harmony Linear Accelerator featuring an integrated gantry-mounted display screen, an opportunity arose to improve treatment efficiency, reduce setup errors, and better leverage integrated technology. The aim of this project was to transition from traditional word-based setup notes to a combined, site-specific, multimodal setup system that fully utilizes the integrated display screen, standardizes setup information, and supports safe, accurate treatment delivery—particularly in the context of a fast-paced clinic with increasing treatment complexity and multi-site palliative care.</div></div><div><h3>Methods/Process</h3><div>The transition involved redesigning setup documentation to consolidate all relevant setup information into a single, site-specific display. This included the development of a structured library of setup devices, eScribe templates generated from CT simulation, tattoo schematics with anatomical references, and site-specific setup photographs. Devices associated with a higher incidence of setup error were identified and assigned additional verification steps. Each treatment site for a patient maintains its own distinct setup information to minimize cross-site confusion. An initial working group trialed multiple iterations directly on the Elekta Harmony Linear Accelerator before standardizing the approach. This process resulted in minimizing free-text setup notes in favor of visual and structured elements. Implementation was phased, beginning with simpler and more standardized treatment sites such as lower gastrointestinal (GI) and genitourinary (GU) setups. Once these workflows were stabilized, the project expanded to sites with more complex settings, including head and neck, abdominal, and thoracic treatments involving specialized immobilization devices and multi-parameter positioning. Future sites identified for transition include spinal stereotactic body radiation therapy (SBRT) spine and four-field breast treatments.</div></div><div><h3>Results or Benefits/Challenges</h3><div>A primary benefit of the new system is that all setup information is presented on a single screen without scrolling, reducing cognitive load and the risk of missed details. This is particularly beneficial for complex palliative patients receiving treatment to multiple sites, as each site’s setup is clearly separated and visually distinct. The integrated display enhances workflow efficiency, consistency, and clarity for therapists at the treatment unit. Challenges included an initial learning curve for staff and determining the most effective visual presentation of setup information. Early implementation relied on one-hour formal in-service sessions and written “how-to” documents, which generated numerous questions and revealed inconsistencies in understanding and knowledge retention. For subsequent site implementations, system features were introduced more gradually using a scaffolding approach. A Plan-Do-Check-Act framework was applied to further refine both the setup information and the training process. Smaller group huddles, informal discussions, and hands-on demonstrations at the treatment unit proved more effective, allowing staff to practice with test patients and ask questions in real time.</div></div><div><h3>Conclusions/Impact</h3><div>Staff have successfully adapted to the new presentation of setup information and integrated it into routine clinical practice. The phased rollout, combined with unit-based, hands-on education and site-specific documentation, supported consistent adoption. This project demonstrates how integrated display technology, standardized visual setup tools, and adaptive education strategies can enhance treatment delivery and support safe, efficient radiation therapy in a modern clinical environment.</div></div>","PeriodicalId":46420,"journal":{"name":"Journal of Medical Imaging and Radiation Sciences","volume":"57 4","pages":"Article 102376"},"PeriodicalIF":2.3000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Imaging and Radiation Sciences","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1939865426001906","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/15 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose/Aim

For over a decade, our institution relied on free-text setup notes within the MOSAIQ notes section to guide radiation treatment delivery. With the installation of an Elekta Harmony Linear Accelerator featuring an integrated gantry-mounted display screen, an opportunity arose to improve treatment efficiency, reduce setup errors, and better leverage integrated technology. The aim of this project was to transition from traditional word-based setup notes to a combined, site-specific, multimodal setup system that fully utilizes the integrated display screen, standardizes setup information, and supports safe, accurate treatment delivery—particularly in the context of a fast-paced clinic with increasing treatment complexity and multi-site palliative care.

Methods/Process

The transition involved redesigning setup documentation to consolidate all relevant setup information into a single, site-specific display. This included the development of a structured library of setup devices, eScribe templates generated from CT simulation, tattoo schematics with anatomical references, and site-specific setup photographs. Devices associated with a higher incidence of setup error were identified and assigned additional verification steps. Each treatment site for a patient maintains its own distinct setup information to minimize cross-site confusion. An initial working group trialed multiple iterations directly on the Elekta Harmony Linear Accelerator before standardizing the approach. This process resulted in minimizing free-text setup notes in favor of visual and structured elements. Implementation was phased, beginning with simpler and more standardized treatment sites such as lower gastrointestinal (GI) and genitourinary (GU) setups. Once these workflows were stabilized, the project expanded to sites with more complex settings, including head and neck, abdominal, and thoracic treatments involving specialized immobilization devices and multi-parameter positioning. Future sites identified for transition include spinal stereotactic body radiation therapy (SBRT) spine and four-field breast treatments.

Results or Benefits/Challenges

A primary benefit of the new system is that all setup information is presented on a single screen without scrolling, reducing cognitive load and the risk of missed details. This is particularly beneficial for complex palliative patients receiving treatment to multiple sites, as each site’s setup is clearly separated and visually distinct. The integrated display enhances workflow efficiency, consistency, and clarity for therapists at the treatment unit. Challenges included an initial learning curve for staff and determining the most effective visual presentation of setup information. Early implementation relied on one-hour formal in-service sessions and written “how-to” documents, which generated numerous questions and revealed inconsistencies in understanding and knowledge retention. For subsequent site implementations, system features were introduced more gradually using a scaffolding approach. A Plan-Do-Check-Act framework was applied to further refine both the setup information and the training process. Smaller group huddles, informal discussions, and hands-on demonstrations at the treatment unit proved more effective, allowing staff to practice with test patients and ask questions in real time.

Conclusions/Impact

Staff have successfully adapted to the new presentation of setup information and integrated it into routine clinical practice. The phased rollout, combined with unit-based, hands-on education and site-specific documentation, supported consistent adoption. This project demonstrates how integrated display technology, standardized visual setup tools, and adaptive education strategies can enhance treatment delivery and support safe, efficient radiation therapy in a modern clinical environment.
通过集成龙门式多模式设置信息显示优化放射治疗设置
目的/目的十多年来,我们的机构依靠MOSAIQ笔记部分的自由文本设置笔记来指导放射治疗的提供。随着Elekta Harmony直线加速器的安装,该加速器具有集成的龙门式显示屏,从而有机会提高处理效率,减少设置错误,并更好地利用集成技术。该项目的目的是从传统的基于文字的设置笔记过渡到一个综合的、特定地点的、多模式的设置系统,该系统充分利用集成显示屏,标准化设置信息,并支持安全、准确的治疗交付,特别是在快节奏的诊所中,治疗复杂性和多地点的缓和治疗日益增加。转换涉及重新设计安装文档,以将所有相关的安装信息合并到单个特定于站点的显示中。这包括一个结构化的安装设备库的开发,从CT模拟生成的eScribe模板,带有解剖参考的纹身示意图,以及特定地点的安装照片。确定与设置错误发生率较高相关的设备并分配额外的验证步骤。患者的每个治疗点都维护自己独特的设置信息,以尽量减少跨站点的混淆。在标准化方法之前,最初的工作组直接在Elekta Harmony线性加速器上进行了多次迭代试验。这个过程的结果是最小化自由文本设置注释,支持视觉和结构化元素。实施是分阶段进行的,从更简单和更标准化的治疗地点开始,如下胃肠道(GI)和泌尿生殖系统(GU)设置。一旦这些工作流程稳定下来,该项目将扩展到更复杂的部位,包括头颈部、腹部和胸部的治疗,包括专门的固定设备和多参数定位。未来确定的转移部位包括脊柱立体定向体放射治疗(SBRT)脊柱和四场乳房治疗。结果或好处/挑战新系统的一个主要好处是,所有的设置信息都显示在一个屏幕上,不需要滚动,减少了认知负荷和错过细节的风险。这对于接受多个部位治疗的复杂姑息治疗患者尤其有益,因为每个部位的设置是明确分开的,在视觉上是不同的。集成显示器提高了工作流程的效率、一致性和治疗单位治疗师的清晰度。挑战包括员工的初始学习曲线和确定设置信息的最有效的视觉表示。早期的实现依赖于一个小时的正式在职会议和书面的“如何”文档,这产生了许多问题,并揭示了理解和知识保留方面的不一致。对于后续的站点实现,系统特性是使用脚手架方法逐渐引入的。应用计划-执行-检查-行动框架进一步完善设置信息和培训过程。事实证明,较小的小组会议、非正式讨论和治疗单元的实际演示更有效,使工作人员能够与测试患者进行练习,并实时提出问题。结论/影响工作人员已经成功地适应了新的设置信息的呈现,并将其纳入常规临床实践。分阶段推出,结合基于单元的实践教育和特定站点的文档,支持一致的采用。该项目展示了集成显示技术、标准化视觉设置工具和适应性教育策略如何在现代临床环境中增强治疗交付和支持安全、有效的放射治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Medical Imaging and Radiation Sciences
Journal of Medical Imaging and Radiation Sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.30
自引率
11.10%
发文量
231
审稿时长
53 days
期刊介绍: Journal of Medical Imaging and Radiation Sciences is the official peer-reviewed journal of the Canadian Association of Medical Radiation Technologists. This journal is published four times a year and is circulated to approximately 11,000 medical radiation technologists, libraries and radiology departments throughout Canada, the United States and overseas. The Journal publishes articles on recent research, new technology and techniques, professional practices, technologists viewpoints as well as relevant book reviews.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书